EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

CONTROL DEVICES NVR20-0A006 Vacuum Relief Valve - Pressure & Vacuum Relief Valves for Regenerative Blowers
CONTROL DEVICESPressure & Vacuum Relief Valves for Regenerative Blowers

CONTROL DEVICES NVR20-0A006 Vacuum Relief Valve

Katup pelepas vakum CONTROL DEVICES tipe NVR20-0A006 (nomor bagian 3G-OTH-189390 / VFZ401A-7W) dirancang khusus untuk melindungi blower regeneratif dari tekanan vakum berlebih. Dengan batas preset 82 in wc dan…

SKU 3G-OTH-142174

Juga terdaftar sebagai: NVR200A006 · NVR20 0A006

Merek
CONTROL DEVICES
Item
NVR20-0A006 Vacuum Relief Valve
Part Number
NVR20-0A006
Kategori
Pressure & Vacuum Relief Valves for Regenerative Blowers
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CONTROL DEVICES
Manufacturer Part Number
NVR20-0A006
Type
82 in wc Preset Limit
Outside Dia
5 in

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

CONTROL DEVICES Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Katup pelepas vakum CONTROL DEVICES tipe NVR20-0A006 (nomor bagian 3G-OTH-189390 / VFZ401A-7W) dirancang khusus untuk melindungi blower regeneratif dari tekanan vakum berlebih. Dengan batas preset 82 in wc dan diameter luar 5 in, katup ini memastikan operasi sistem pembakaran industri Anda tetap aman dan andal.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa fungsi CONTROL DEVICES Blower Relief Valve: Vacuum?

Katup ini berfungsi sebagai pengaman vakum pada blower regeneratif, dengan batas preset 82 in wc. Ketika tekanan vakum melebihi batas, katup akan membuka untuk melepaskan tekanan, mencegah kerusakan pada blower dan sistem peralatan pembakaran.

Apa spesifikasi CONTROL DEVICES NVR20-0A006?

Spesifikasi katup ini meliputi tipe NVR20-0A006 dengan batas preset 82 in wc, diameter luar 5 in, dan nomor bagian alternatif 3G-OTH-189390 atau VFZ401A-7W. Produk ini diproduksi oleh CONTROL DEVICES dan dirancang untuk aplikasi vakum pada blower regeneratif.

Bagaimana cara memilih katup pelepas vakum untuk blower regeneratif?

Pilih katup dengan batas tekanan vakum yang sesuai, seperti CONTROL DEVICES NVR20-0A006 dengan preset 82 in wc. Pastikan diameter luar (5 in) cocok dengan saluran blower Anda. Untuk aplikasi spesifik, hubungi kami untuk konsultasi teknis.

Digunakan dalam

Aplikasi umum untuk CONTROL DEVICES
Compressed air systems — SB75-0A150 soft seat safety valve with 3/4 in MNPT and 150 psi preset for overpressure protection.
Pneumatic control circuits — VR25-100 vacuum and pressure relief valve with 1/4 in MNPT for combined overpressure and vacuum protection.
Process piping — VRGSS038-001 stainless steel vacuum relief valve with 3/8 in MNPT for corrosive environments.
Tank protection — VRGSS300-001 stainless steel vacuum relief valve with 3 in MNPT for large tanks and pipelines.
Low-pressure pneumatic systems — VR38-100 brass vacuum and pressure relief valve with 3/8 in MNPT for 0-14.7 psi and 0-27 in Hg.
General industrial maintenance — VR75-100 brass vacuum and pressure relief valve with 3/4 in MNPT for compressed air systems.
Not sure this is the right part? Photo-identify it→

CONTROL DEVICES Produk

3G Electric memasok CONTROL DEVICES pressure & vacuum relief valves for regenerative blowers. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Compatible alternatives & equivalents

Lainnya dari CONTROL DEVICES

Lihat semua CONTROL DEVICES suku cadang →
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 443 in wc and an outside diameter of 5.7 in. The valve protects equipment from overpressure or vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 443 in wc and an outside diameter of 5.7 in. The valve protects equipment from overpressure or vacuum conditions
This pressure and vacuum relief valve is designed for regenerative blowers in pneumatic conveying, aeration, and vacuum systems. It automatically vents excess pressure at its 277 in wc preset limit to protect equipment from overpressure or vacuum conditions. The valve has a 5 in outside diameter
CONTROL DEVICES
This pressure and vacuum relief valve is designed for regenerative blowers in pneumatic conveying, aeration, and vacuum systems. It automatically vents excess pressure at its 277 in wc preset limit to protect equipment from overpressure or vacuum conditions. The valve has a 5 in outside diameter
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 332 in wc and an outside diameter of 6.9 in. The valve vents excess air to protect blower systems from overpressure or vacuum conditions in industrial air-handling applications
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 332 in wc and an outside diameter of 6.9 in. The valve vents excess air to protect blower systems from overpressure or vacuum conditions in industrial air-handling applications
This pressure and vacuum relief valve is designed for use with regenerative blowers in pneumatic systems. It has a preset limit of 194 in wc and an outside diameter of 5 in. The valve automatically vents excess pressure or vacuum to protect the blower and maintain system stability
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in pneumatic systems. It has a preset limit of 194 in wc and an outside diameter of 5 in. The valve automatically vents excess pressure or vacuum to protect the blower and maintain system stability
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 5 psi preset limit and a 2 1/2 in NPT inlet size, protecting equipment from overpressure and vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 5 psi preset limit and a 2 1/2 in NPT inlet size, protecting equipment from overpressure and vacuum conditions
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 332 inches of water column and an outside diameter of 5 inches. The valve vents excess air to protect the blower from overpressure or vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 332 inches of water column and an outside diameter of 5 inches. The valve vents excess air to protect the blower from overpressure or vacuum conditions
Vacuum relief valve with a preset limit of 108 in wc and 5 in outside diameter. Designed for regenerative blower systems to protect against over-vacuum conditions
CONTROL DEVICES
Vacuum relief valve with a preset limit of 108 in wc and 5 in outside diameter. Designed for regenerative blower systems to protect against over-vacuum conditions
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications