Supplying Indonesia from Singapore. Goods are offered EXW Singapore — collection from our Singapore facility.

3G Electric
CONTROL DEVICES NVR30-0A014 Pressure & Vacuum Relief Valve - Pressure & Vacuum Relief Valves for Regenerative Blowers
CONTROL DEVICESPressure & Vacuum Relief Valves for Regenerative Blowers

CONTROL DEVICES NVR30-0A014 Pressure & Vacuum Relief Valve

CONTROL DEVICES NVR30-0A014 adalah katup pelepas vakum (vacuum relief valve) yang dirancang khusus untuk blower regeneratif. Katup ini memiliki preset limit 190 in wc dan diameter luar 6,9 inci, memastikan…

SKU 3G-OTH-142231

Juga terdaftar sebagai: NVR300A014 · NVR30 0A014

Merek
CONTROL DEVICES
Item
NVR30-0A014 Pressure & Vacuum Relief Valve
Part Number
NVR30-0A014
Kategori
Pressure & Vacuum Relief Valves for Regenerative Blowers
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CONTROL DEVICES
Manufacturer Part Number
NVR30-0A014
Type
190 in wc Preset Limit
Outside Dia
6.9 in

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

CONTROL DEVICES Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

CONTROL DEVICES NVR30-0A014 adalah katup pelepas vakum (vacuum relief valve) yang dirancang khusus untuk blower regeneratif. Katup ini memiliki preset limit 190 in wc dan diameter luar 6,9 inci, memastikan perlindungan tekanan yang akurat pada sistem blower Anda. Sebagai komponen peralatan industri yang andal, katup ini membantu menjaga kinerja optimal dan mencegah kerusakan akibat tekanan vakum berlebih.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa fungsi CONTROL DEVICES NVR30-0A014?

CONTROL DEVICES NVR30-0A014 berfungsi sebagai katup pelepas vakum untuk blower regeneratif. Katup ini melindungi sistem dari tekanan vakum berlebih dengan preset limit 190 in wc, sehingga menjaga kinerja blower tetap stabil dan aman.

Apa spesifikasi CONTROL DEVICES NVR30-0A014?

Spesifikasi CONTROL DEVICES NVR30-0A014 meliputi tipe preset limit 190 in wc, diameter luar 6,9 inci, dan nomor komponen NVR30-0A014. Katup ini dirancang khusus untuk aplikasi vakum pada blower regeneratif.

Bagaimana cara memilih katup pelepas vakum untuk blower regeneratif?

Pilih katup pelepas vakum seperti CONTROL DEVICES NVR30-0A014 dengan preset limit yang sesuai, misalnya 190 in wc. Pastikan diameter luar (6,9 inci) kompatibel dengan sistem blower Anda untuk perlindungan tekanan yang optimal.

Digunakan dalam

Aplikasi umum untuk CONTROL DEVICES
Compressed air systems — SB75-0A150 soft seat safety valve with 3/4 in MNPT and 150 psi preset for overpressure protection.
Pneumatic control circuits — VR25-100 vacuum and pressure relief valve with 1/4 in MNPT for combined overpressure and vacuum protection.
Process piping — VRGSS038-001 stainless steel vacuum relief valve with 3/8 in MNPT for corrosive environments.
Tank protection — VRGSS300-001 stainless steel vacuum relief valve with 3 in MNPT for large tanks and pipelines.
Low-pressure pneumatic systems — VR38-100 brass vacuum and pressure relief valve with 3/8 in MNPT for 0-14.7 psi and 0-27 in Hg.
General industrial maintenance — VR75-100 brass vacuum and pressure relief valve with 3/4 in MNPT for compressed air systems.
Not sure this is the right part? Photo-identify it→

CONTROL DEVICES Produk

3G Electric memasok CONTROL DEVICES pressure & vacuum relief valves for regenerative blowers. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Compatible alternatives & equivalents

Lainnya dari CONTROL DEVICES

Lihat semua CONTROL DEVICES suku cadang →
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 443 in wc and an outside diameter of 5.7 in. The valve protects equipment from overpressure or vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 443 in wc and an outside diameter of 5.7 in. The valve protects equipment from overpressure or vacuum conditions
This pressure and vacuum relief valve is designed for regenerative blowers in pneumatic conveying, aeration, and vacuum systems. It automatically vents excess pressure at its 277 in wc preset limit to protect equipment from overpressure or vacuum conditions. The valve has a 5 in outside diameter
CONTROL DEVICES
This pressure and vacuum relief valve is designed for regenerative blowers in pneumatic conveying, aeration, and vacuum systems. It automatically vents excess pressure at its 277 in wc preset limit to protect equipment from overpressure or vacuum conditions. The valve has a 5 in outside diameter
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 332 in wc and an outside diameter of 6.9 in. The valve vents excess air to protect blower systems from overpressure or vacuum conditions in industrial air-handling applications
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 332 in wc and an outside diameter of 6.9 in. The valve vents excess air to protect blower systems from overpressure or vacuum conditions in industrial air-handling applications
This pressure and vacuum relief valve is designed for use with regenerative blowers in pneumatic systems. It has a preset limit of 194 in wc and an outside diameter of 5 in. The valve automatically vents excess pressure or vacuum to protect the blower and maintain system stability
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in pneumatic systems. It has a preset limit of 194 in wc and an outside diameter of 5 in. The valve automatically vents excess pressure or vacuum to protect the blower and maintain system stability
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 5 psi preset limit and a 2 1/2 in NPT inlet size, protecting equipment from overpressure and vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 5 psi preset limit and a 2 1/2 in NPT inlet size, protecting equipment from overpressure and vacuum conditions
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 332 inches of water column and an outside diameter of 5 inches. The valve vents excess air to protect the blower from overpressure or vacuum conditions
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a preset limit of 332 inches of water column and an outside diameter of 5 inches. The valve vents excess air to protect the blower from overpressure or vacuum conditions
Vacuum relief valve with a preset limit of 108 in wc and 5 in outside diameter. Designed for regenerative blower systems to protect against over-vacuum conditions
CONTROL DEVICES
Vacuum relief valve with a preset limit of 108 in wc and 5 in outside diameter. Designed for regenerative blower systems to protect against over-vacuum conditions
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications
CONTROL DEVICES
This pressure and vacuum relief valve is designed for use with regenerative blowers. It has a preset limit of 100 psi and a 1/4 in NPT inlet size. The valve vents excess pressure to protect blower systems in pneumatic applications