EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

MYERS SB24SRM-01 Simplex Sewage Ejector Pump System - Simplex Sewage Ejector Pump Systems
MYERSSimplex Sewage Ejector Pump Systems

MYERS SB24SRM-01 Simplex Sewage Ejector Pump System

Sistem pompa ejektor limbah MYERS tipe Simplex dengan kapasitas tangki 38,5 galon ini dirancang untuk aplikasi pembuangan air limbah domestik dan komersial ringan. Dilengkapi motor 2/5 hp, 115V AC, dan mampu…

SKU 3G-OTH-84805

Juga terdaftar sebagai: SB24SRM01 · SB24SRM 01

Merek
MYERS
Item
SB24SRM-01 Simplex Sewage Ejector Pump System
Part Number
SB24SRM-01
Kategori
Simplex Sewage Ejector Pump Systems
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

MYERS
Manufacturer Part Number
SB24SRM-01
Type
2/5 hp, 60 gpm Flow Rate @ 10' of Head, 4 in
AC
115V
Switch
Piggyback Tether Float
Rated Voltage
115V AC

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

MYERS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Sistem pompa ejektor limbah MYERS tipe Simplex dengan kapasitas tangki 38,5 galon ini dirancang untuk aplikasi pembuangan air limbah domestik dan komersial ringan. Dilengkapi motor 2/5 hp, 115V AC, dan mampu menghasilkan laju aliran 60 gpm pada head 10 kaki. Sistem ini menggunakan sakelar pelampung tether piggyback dan memiliki saluran buang di bagian atas (4 inci).

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Untuk apa sistem pompa ejektor limbah MYERS digunakan?

Sistem pompa ejektor limbah MYERS SB24SRM-01 digunakan untuk memompa air limbah dari saluran pembuangan di bawah permukaan tanah, seperti di ruang bawah tanah atau area yang lebih rendah dari saluran utama. Sistem ini ideal untuk rumah tinggal atau bangunan komersial kecil yang memerlukan pembuangan air limbah secara otomatis.

Apa spesifikasi teknis sistem pompa ejektor limbah MYERS SB24SRM-01?

Spesifikasi teknis MYERS SB24SRM-01 meliputi: motor 2/5 hp, tegangan 115V AC, laju aliran 60 gpm pada head 10 kaki, sakelar pelampung tether piggyback, saluran buang di bagian atas berukuran 4 inci, dan kapasitas tangki 38,5 galon. Sistem ini adalah tipe Simplex untuk aplikasi sewage ejector.

Bagaimana cara memilih sistem pompa ejektor limbah yang tepat?

Pemilihan sistem pompa ejektor limbah bergantung pada kebutuhan head total dan laju aliran. Untuk aplikasi dengan head hingga 10 kaki, MYERS SB24SRM-01 dengan laju aliran 60 gpm dan motor 2/5 hp 115V AC dapat menjadi pilihan. Pastikan juga kapasitas tangki (38,5 galon) sesuai dengan volume air limbah yang akan ditangani.

Digunakan dalam

Aplikasi umum untuk MYERS
Residential basement dewatering — MYERS MSCI33V10 submersible sump pump with piggyback vertical float switch for automatic operation.
Crawl space water removal — MYERS MS33V10 1/3 hp sump pump delivering 40 gpm at 10 feet of head.
Low-lying area drainage — MYERS MS33PV10 submersible sump pump with 1-1/2 inch FNPT discharge for permanent or temporary installation.
Automotive tire balancing — MYERS Rim Gauge (MPN 61232) for determining wheel weight application on cars.
Tire repair — MYERS Heavy-Duty T AWL (MPN 47024) for cleaning and enlarging punctures before plug insertion.
Tire patch vulcanization — MYERS Ball Bearing Stitcher (MPN 802793) for pressing and sealing repair patches.
Not sure this is the right part? Photo-identify it→

MYERS Produk

3G Electric memasok MYERS simplex sewage ejector pump systems. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Aksesori Pompa →Katup & Regulasi →Motor & Penggerak →Semua Produk →

Compatible alternatives & equivalents

Cross-referenced by specification & description
This MYERS sewage ejector pump is designed for moving wastewater from below-grade fixtures such as basement bathrooms or laundry rooms to a higher-level sewer line. It features a 1/2 hp single-phase motor, 115V AC, and delivers 133 gpm at 10' of head. The pump includes a piggyback tether float switch, thermoplastic impeller, and vertical discharge orientation. Not rated for hazardous locations
MYERS
This MYERS sewage ejector pump is designed for moving wastewater from below-grade fixtures such as basement bathrooms or laundry rooms to a higher-level sewer line. It features a 1/2 hp single-phase motor, 115V AC, and delivers 133 gpm at 10' of head. The pump includes a piggyback tether float switch, thermoplastic impeller, and vertical discharge orientation. Not rated for hazardous locations
MYERS
MYERS
This MYERS sewage ejector pump is designed for moving wastewater from below-grade fixtures such as basement bathrooms or laundry rooms to a higher-level sewer line. It features a 1/2 hp single-phase motor, 230V AC rated voltage, and delivers 130 gpm at 10' of head. The pump includes a piggyback tether float switch, ductile iron impeller, and vertical discharge orientation. Not rated for hazardous locations
MYERS
MYERS
Single-phase, 1 1/2 hp sewage ejector pump rated for 230V AC with 12.8 A draw. Features ductile iron impeller and vertical discharge orientation. Handles solids up to 2 in. diameter. Suitable for wastewater removal in residential and light commercial applications requiring vertical discharge. Switch not included
MYERS
MYERS
Single-phase, 1 hp sewage ejector pump rated for 230V AC. Features a ductile iron impeller, vertical discharge with 2 in FNPT connection, and handles solids up to 2 in diameter. Suitable for wastewater removal in residential and light commercial applications where gravity drainage is not available. Switch not included
MYERS
MYERS
Single-phase, 2 hp sewage ejector pump rated for 230V AC. Features a ductile iron impeller, cast iron construction, and vertical discharge with 2 in FNPT connection. Handles solids up to 2 in diameter. Switch not included; not rated for hazardous locations. Suitable for moving wastewater and solids from below-grade fixtures to higher sewer lines in residential and light commercial applications
This MYERS effluent pump is designed for general purpose wastewater handling in residential and light commercial applications. It features a cast iron impeller and a piggyback tether float switch for automatic operation. The pump delivers 87 gpm at 10 feet of head with a maximum head of 44 feet, suitable for moderate lift requirements
MYERS
This MYERS effluent pump is designed for general purpose wastewater handling in residential and light commercial applications. It features a cast iron impeller and a piggyback tether float switch for automatic operation. The pump delivers 87 gpm at 10 feet of head with a maximum head of 44 feet, suitable for moderate lift requirements

Lainnya dari MYERS

Lihat semua MYERS suku cadang →
This simplex sewage ejector pump system includes a 30-gallon basin and a 2/5 hp, 115V AC pump with a top discharge. It delivers 60 gpm at 10 feet of head and is controlled by a piggyback tether float switch. Used for moving wastewater from below-grade plumbing fixtures to the main sewer line where gravity drainage is not possible
MYERS
This simplex sewage ejector pump system includes a 30-gallon basin and a 2/5 hp, 115V AC pump with a top discharge. It delivers 60 gpm at 10 feet of head and is controlled by a piggyback tether float switch. Used for moving wastewater from below-grade plumbing fixtures to the main sewer line where gravity drainage is not possible