EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

Siemens SLJC464004GJXD6 Nonfusible Bus Plug - Siemens Nonfusible Bus Plugs
SiemensSiemens Nonfusible Bus Plugs

Siemens SLJC464004GJXD6 Nonfusible Bus Plug

Siemens Bus Plug 400 A Amps tipe JXD6 adalah bus plug nonfusible yang dirancang untuk digunakan pada Siemens Sentron Busway. Produk ini memiliki rating 600V AC, 3 fasa, 4 kabel dengan ground, dan mampu menangani arus…

SKU 3G-OTH-135028

Merek
Siemens
Item
SLJC464004GJXD6 Nonfusible Bus Plug
Part Number
SLJC464004GJXD6
Kategori
Siemens Nonfusible Bus Plugs
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Siemens
Manufacturer Part Number
SLJC464004GJXD6
Type
JXD6, Siemens Sentron Busway
AC
600V
Phase
3
Wire With Ground
4

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

Siemens Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Siemens Bus Plug 400 A Amps tipe JXD6 adalah bus plug nonfusible yang dirancang untuk digunakan pada Siemens Sentron Busway. Produk ini memiliki rating 600V AC, 3 fasa, 4 kabel dengan ground, dan mampu menangani arus hingga 400 A. Ideal untuk distribusi daya pada sistem busway industri, bus plug ini memastikan koneksi yang andal dan aman dalam aplikasi pembakaran industri atau ketel uap.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa spesifikasi Siemens Bus Plug 400 A Amps tipe JXD6?

Siemens Bus Plug 400 A Amps tipe JXD6 memiliki rating 600V AC, 3 fasa, 4 kabel dengan ground, dan arus 400 A. Produk ini dirancang untuk Siemens Sentron Busway dan merupakan tipe nonfusible.

Untuk apa Siemens Bus Plug 400 A Amps digunakan?

Bus plug ini digunakan untuk mendistribusikan daya listrik pada sistem Siemens Sentron Busway di lingkungan industri, seperti pabrik pengolahan kelapa sawit, semen, atau fasilitas dengan peralatan pembakaran dan ketel uap.

Bagaimana cara memilih Siemens Bus Plug yang tepat untuk sistem busway?

Pastikan bus plug sesuai dengan tipe busway yang digunakan, seperti Siemens Sentron Busway. Periksa rating tegangan (600V AC), arus (400 A), jumlah fasa (3), dan konfigurasi kabel (4 dengan ground) agar kompatibel dengan sistem Anda.

Digunakan dalam

Aplikasi umum untuk Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks
Not sure this is the right part? Photo-identify it→

Siemens Produk

3G Electric memasok Siemens siemens nonfusible bus plugs. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Fusible bus plug rated 200 A at 600V AC, designed for use with Siemens Sentron Busway. Accepts H/K/R fuse classes and features an SL configuration. Provides a fused disconnect point for tapping power from busway systems in electrical distribution networks
Siemens
Fusible bus plug rated 200 A at 600V AC, designed for use with Siemens Sentron Busway. Accepts H/K/R fuse classes and features an SL configuration. Provides a fused disconnect point for tapping power from busway systems in electrical distribution networks
Fusible bus plug for Siemens Sentron Busway, rated 600V AC and 60 A. Supports 3-phase, 3-wire configurations with SL enclosure type and H/K/R fuse class compatibility. Used to connect branch circuits to busway for overcurrent protection in industrial power distribution
Siemens
Fusible bus plug for Siemens Sentron Busway, rated 600V AC and 60 A. Supports 3-phase, 3-wire configurations with SL enclosure type and H/K/R fuse class compatibility. Used to connect branch circuits to busway for overcurrent protection in industrial power distribution
Fusible bus plug for Siemens Sentron Busway, rated 100 A at 600V AC. Accepts H/K/R fuse classes. Used to tap power and provide overcurrent protection for branch circuits in industrial electrical distribution systems
Siemens
Fusible bus plug for Siemens Sentron Busway, rated 100 A at 600V AC. Accepts H/K/R fuse classes. Used to tap power and provide overcurrent protection for branch circuits in industrial electrical distribution systems

Lainnya dari Siemens

Lihat semua Siemens suku cadang →
Nonfusible bus plug rated 100 A at 600V AC, type E, for use with Siemens Sentron Busway. 3-phase, 4-wire with ground configuration. Connects branch circuits to busway for power distribution in industrial settings
Siemens
Nonfusible bus plug rated 100 A at 600V AC, type E, for use with Siemens Sentron Busway. 3-phase, 4-wire with ground configuration. Connects branch circuits to busway for power distribution in industrial settings
Nonfusible bus plug rated 30 A at 480V AC, 3-phase, 4-wire with ground. Type E design for use with Siemens Sentron Busway. Provides a disconnect point for tapping power in industrial power distribution systems
Siemens
Nonfusible bus plug rated 30 A at 480V AC, 3-phase, 4-wire with ground. Type E design for use with Siemens Sentron Busway. Provides a disconnect point for tapping power in industrial power distribution systems
Nonfusible bus plug for use with Siemens Sentron Busway. Provides a tap-off point for power distribution in busway systems. Rated 150 A at 600V AC. Suitable for industrial and commercial facilities to power equipment, lighting, or machinery
Siemens
Nonfusible bus plug for use with Siemens Sentron Busway. Provides a tap-off point for power distribution in busway systems. Rated 150 A at 600V AC. Suitable for industrial and commercial facilities to power equipment, lighting, or machinery
This nonfusible bus plug is rated 175 A at 600 V AC and configured for 3-phase, 4-wire power distribution. Designed for use with Siemens Sentron Busway systems, the HFD6 unit provides a grounded connection point to tap power without integrated overcurrent protection. Typical applications include industrial and commercial facilities requiring branch power takeoff from a busway
Siemens
This nonfusible bus plug is rated 175 A at 600 V AC and configured for 3-phase, 4-wire power distribution. Designed for use with Siemens Sentron Busway systems, the HFD6 unit provides a grounded connection point to tap power without integrated overcurrent protection. Typical applications include industrial and commercial facilities requiring branch power takeoff from a busway