EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

JOHNSON CONTROLS T-5800-1 Single-Input Receiver-Controller - Single-Input Receiver-Controllers
JOHNSON CONTROLSSingle-Input Receiver-Controllers

JOHNSON CONTROLS T-5800-1 Single-Input Receiver-Controller

JOHNSON CONTROLS Pneumatic Receiver Controller: Single Input (T-5800-1) adalah pengontrol penerima pneumatik dengan input tunggal yang dirancang untuk aplikasi kontrol proporsional. Perangkat ini menerima sinyal…

SKU 3G-OTH-69929

Juga terdaftar sebagai: T58001 · T 5800 1

Merek
JOHNSON CONTROLS
Item
T-5800-1 Single-Input Receiver-Controller
Part Number
T-5800-1
Kategori
Single-Input Receiver-Controllers
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

JOHNSON CONTROLS
Manufacturer Part Number
T-5800-1
Type
Proportional
Signal
3 psi to 9 psi
Supply
20 psi
Control Action
Direct Acting/Reverse Acting
Control Signal
Proportional

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

JOHNSON CONTROLS Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

JOHNSON CONTROLS Pneumatic Receiver Controller: Single Input (T-5800-1) adalah pengontrol penerima pneumatik dengan input tunggal yang dirancang untuk aplikasi kontrol proporsional. Perangkat ini menerima sinyal input 3 psi hingga 9 psi dan memerlukan suplai udara 20 psi. Tersedia dalam aksi kontrol Direct Acting atau Reverse Acting, produk ini ideal untuk sistem HVAC dan kontrol proses industri yang memerlukan respons proporsional yang presisi.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa fungsi dari JOHNSON CONTROLS Pneumatic Receiver Controller T-5800-1?

JOHNSON CONTROLS Pneumatic Receiver Controller T-5800-1 berfungsi sebagai pengontrol penerima pneumatik dengan input tunggal yang memberikan kontrol proporsional. Perangkat ini menerima sinyal input 3 psi hingga 9 psi dan memerlukan suplai udara 20 psi. Tersedia dalam aksi Direct Acting atau Reverse Acting, cocok untuk aplikasi HVAC dan kontrol proses.

Apa spesifikasi teknis dari JOHNSON CONTROLS T-5800-1?

Spesifikasi teknis JOHNSON CONTROLS T-5800-1 meliputi tipe proporsional, sinyal input 3 psi hingga 9 psi, suplai 20 psi, dan aksi kontrol Direct Acting atau Reverse Acting. Nomor bagian pabrikan adalah T-5800-1. Produk ini dirancang untuk kontrol proporsional yang akurat dalam sistem pneumatik.

Bagaimana cara memilih antara Direct Acting dan Reverse Acting pada JOHNSON CONTROLS T-5800-1?

Pemilihan antara Direct Acting atau Reverse Acting pada JOHNSON CONTROLS T-5800-1 tergantung pada kebutuhan sistem kontrol Anda. Direct Acting meningkatkan sinyal output seiring kenaikan sinyal input, sedangkan Reverse Acting sebaliknya. Pastikan Anda menyesuaikan dengan konfigurasi aktuator atau katup yang digunakan dalam sistem pneumatik Anda.

Digunakan dalam

Aplikasi umum untuk JOHNSON CONTROLS
Building automation systems — Johnson Controls TE-6361M-1 duct temperature sensor for monitoring duct temperatures in HVAC systems.
Refrigeration systems — Johnson Controls SEC99AA-24C armored capillary tubing for connecting pressure controls.
HVAC differential pressure control — Johnson Controls P74EA-8C for controlling equipment based on pressure changes.
Liquid flow detection — Johnson Controls F261MAH-V01C paddle flow switch for piping systems.
Hydronic heating and cooling — Johnson Controls VG2431YN globe valve for flow control in water systems.
Refrigeration condensing units — Johnson Controls P66AAB-1C fan speed control for maintaining pressure.
Not sure this is the right part? Photo-identify it→

JOHNSON CONTROLS Produk

3G Electric memasok JOHNSON CONTROLS single-input receiver-controllers. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single-pressure control with SPST contact form, rated 120V AC. Auto reset, open on fall switch action. Pressure range 20 in Hg to 100 psi, differential 7 psi to 50 psi. Used in HVAC and refrigeration systems to protect equipment from low-pressure conditions
JOHNSON CONTROLS
Single-pressure control with SPST contact form, rated 120V AC. Auto reset, open on fall switch action. Pressure range 20 in Hg to 100 psi, differential 7 psi to 50 psi. Used in HVAC and refrigeration systems to protect equipment from low-pressure conditions
This single-pressure control features an SPST contact form with close-on-rise switch action and automatic reset. It is rated for 277V AC and has a pressure range of 20 in Hg to 100 psi with a differential of 7 psi to 50 psi. Typical applications include monitoring and switching circuits in refrigeration, HVAC, and process systems where pressure rise triggers circuit closure
JOHNSON CONTROLS
This single-pressure control features an SPST contact form with close-on-rise switch action and automatic reset. It is rated for 277V AC and has a pressure range of 20 in Hg to 100 psi with a differential of 7 psi to 50 psi. Typical applications include monitoring and switching circuits in refrigeration, HVAC, and process systems where pressure rise triggers circuit closure
Proportional receiver-controller with dual inputs, accepting a 3 psi to 15 psi control signal and requiring a 30 psi supply. Selectable direct or reverse acting control action. Used in HVAC systems to modulate dampers or valves based on pneumatic signals
KMC CONTROLS
Proportional receiver-controller with dual inputs, accepting a 3 psi to 15 psi control signal and requiring a 30 psi supply. Selectable direct or reverse acting control action. Used in HVAC systems to modulate dampers or valves based on pneumatic signals
Wall-mounted direct-acting pneumatic temperature transmitter with a rigid element. Converts temperature changes from 19°F to 129°F into a proportional 13 psi to 25 psi output signal. Features a 5/32 in barb air connection. Used in HVAC systems to control actuators, valves, or dampers
JOHNSON CONTROLS
Wall-mounted direct-acting pneumatic temperature transmitter with a rigid element. Converts temperature changes from 19°F to 129°F into a proportional 13 psi to 25 psi output signal. Features a 5/32 in barb air connection. Used in HVAC systems to control actuators, valves, or dampers
Single-pressure control with SPST contact form rated for 120V AC. Features auto reset and open-on-rise switch action. Pressure range from 20 in Hg to 100 psi with differential of 7 psi to 50 psi. Used in HVAC and refrigeration systems for overpressure protection
JOHNSON CONTROLS
Single-pressure control with SPST contact form rated for 120V AC. Features auto reset and open-on-rise switch action. Pressure range from 20 in Hg to 100 psi with differential of 7 psi to 50 psi. Used in HVAC and refrigeration systems for overpressure protection

Lainnya dari JOHNSON CONTROLS

Lihat semua JOHNSON CONTROLS suku cadang →
Proportional pneumatic receiver-controller for HVAC and industrial control systems. Accepts a 3 psi to 15 psi signal with a 25 psi supply. Control action is selectable between direct acting and reverse acting for modulating dampers or valves
JOHNSON CONTROLS
Proportional pneumatic receiver-controller for HVAC and industrial control systems. Accepts a 3 psi to 15 psi signal with a 25 psi supply. Control action is selectable between direct acting and reverse acting for modulating dampers or valves