EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

MERSEN TRS15/100R Class RK5 Time-Delay Cylindrical Fuse - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN TRS15/100R Class RK5 Time-Delay Cylindrical Fuse

MERSEN Fuse Class RK5 tipe TRS-R Series adalah sekering silinder waktu-tunda (time-delay) dengan rating 150 mA yang dirancang untuk aplikasi proteksi sirkuit industri. Sekering ini memiliki tegangan AC 600 V dan DC…

SKU 3G-OTH-28526

Juga terdaftar sebagai: TRS15100R · TRS15 100R · TRS15-100R

Merek
MERSEN
Item
TRS15/100R Class RK5 Time-Delay Cylindrical Fuse
Part Number
TRS15/100R
Kategori
Time-Delay Cylindrical Fuses
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

MERSEN
Manufacturer Part Number
TRS15/100R
Series
TRS-R
Type
TRS-R Series, Time-Delay, 150 mA, Non-Indicating
AC
600 V
DC
600 V

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

MERSEN Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

MERSEN Fuse Class RK5 tipe TRS-R Series adalah sekering silinder waktu-tunda (time-delay) dengan rating 150 mA yang dirancang untuk aplikasi proteksi sirkuit industri. Sekering ini memiliki tegangan AC 600 V dan DC 600 V, serta tipe non-indicating yang andal untuk sistem kelistrikan di pabrik dan peralatan pembakaran.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa spesifikasi MERSEN Fuse TRS15/100R?

MERSEN Fuse TRS15/100R adalah sekering Class RK5 tipe TRS-R Series dengan rating 150 mA, tegangan AC 600 V dan DC 600 V, serta desain time-delay non-indicating. Spesifikasi ini cocok untuk proteksi sirkuit pada peralatan industri seperti pembakar dan ketel uap.

Untuk apa MERSEN Fuse TRS-R Series digunakan?

MERSEN Fuse TRS-R Series digunakan sebagai pengaman sirkuit listrik pada peralatan industri, termasuk pembakar industri dan sistem kontrol. Dengan karakteristik time-delay, sekering ini melindungi dari lonjakan arus sementara tanpa trip prematur, ideal untuk aplikasi beban induktif.

Bagaimana cara memilih MERSEN Fuse Class RK5 yang tepat?

Pilih MERSEN Fuse Class RK5 berdasarkan tegangan sistem (AC/DC 600 V), rating arus (seperti 150 mA pada TRS15/100R), dan karakteristik time-delay. Pastikan sekering sesuai dengan kebutuhan proteksi sirkuit peralatan industri Anda, seperti pembakar atau ketel uap.

Digunakan dalam

Aplikasi umum untuk MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Produk

3G Electric memasok MERSEN time-delay cylindrical fuses. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Compatible alternatives & equivalents

Lainnya dari MERSEN

Lihat semua MERSEN suku cadang →
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
MERSEN
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
MERSEN
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
Time-delay cylindrical fuse rated 1 A, 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inrush currents, such as motors and control circuits
MERSEN
Time-delay cylindrical fuse rated 1 A, 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inrush currents, such as motors and control circuits
MERSEN TRM Series midget time-delay fuse, rated 3.2 A and 250 V AC, with a 13/32 in x 1 1/2 in body size. Non-indicating type. Suitable for protecting control circuits, motors, and transformers where temporary inrush currents occur
MERSEN
MERSEN TRM Series midget time-delay fuse, rated 3.2 A and 250 V AC, with a 13/32 in x 1 1/2 in body size. Non-indicating type. Suitable for protecting control circuits, motors, and transformers where temporary inrush currents occur
Time-delay cylindrical fuse rated 7 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits subject to inrush currents, such as those with motors, transformers, or control panels
MERSEN
Time-delay cylindrical fuse rated 7 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits subject to inrush currents, such as those with motors, transformers, or control panels
Time-delay cylindrical fuse rated 10 A, 250 V AC, with dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits requiring tolerance to temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN
Time-delay cylindrical fuse rated 10 A, 250 V AC, with dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits requiring tolerance to temporary inrush currents, such as control panels, motor circuits, and power supplies
Class RK5 time-delay cylindrical fuse rated 1 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristics for motor and transformer protection. Suitable for overcurrent protection in industrial power distribution circuits
MERSEN
Class RK5 time-delay cylindrical fuse rated 1 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristics for motor and transformer protection. Suitable for overcurrent protection in industrial power distribution circuits
Midget, time-delay cylindrical fuse rated 5 A, 500 V AC. Body size 13/32 in x 1 1/2 in, non-indicating. Used in control panels, motor starters, and lighting systems to protect against overloads and short circuits where inrush currents occur
MERSEN
Midget, time-delay cylindrical fuse rated 5 A, 500 V AC. Body size 13/32 in x 1 1/2 in, non-indicating. Used in control panels, motor starters, and lighting systems to protect against overloads and short circuits where inrush currents occur