EXW Singapura — diambil di kantor kami. Melayani pelanggan di Indonesia.

Sekering MERSEN: Kelas RK5, Seri TRS-R, Tunda Waktu, 600 mA, 600 V AC, 600 V DC - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

Sekering MERSEN: Kelas RK5, Seri TRS-R, Tunda Waktu, 600 mA, 600 V AC, 600 V DC

MERSEN Fuse Class RK5 tipe TRS-R Series adalah sekering silinder waktu-tunda (time-delay) dengan rating 600 mA, non-indicating, dirancang untuk aplikasi proteksi sirkuit pada tegangan AC dan DC hingga 600 V. Produk…

SKU 3G-OTH-27406

Juga terdaftar sebagai: TRS610R · TRS6 10R · TRS6-10R

Merek
MERSEN
Item
Sekering MERSEN: Kelas RK5, Seri TRS-R, Tunda Waktu, 600 mA, 600 V AC, 600 V DC
Part Number
TRS6/10R
Kategori
Time-Delay Cylindrical Fuses
Tersedia untuk Dipesan
Supplied EXW Singapore
  • Quoted per order — collection from our Singapore facility once ready.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted. Invoices in IDR are paid online through the payment link on the invoice.
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
EXW Singapore
Collect or forward from our office
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

MERSEN
Manufacturer Part Number
TRS6/10R
Series
TRS-R
Type
TRS-R Series, Time-Delay, 600 mA, Non-Indicating
AC
600 V
DC
600 V

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi →
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.
Ask a question

Ajukan pertanyaan

MERSEN Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

MERSEN Fuse Class RK5 tipe TRS-R Series adalah sekering silinder waktu-tunda (time-delay) dengan rating 600 mA, non-indicating, dirancang untuk aplikasi proteksi sirkuit pada tegangan AC dan DC hingga 600 V. Produk ini cocok digunakan sebagai pengaman pada peralatan industri, panel distribusi, dan sistem kontrol yang memerlukan perlindungan arus lebih yang andal.

Supplied to Indonesia — compatible with 50 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Jakarta, Surabaya, Bandung, customs and duties are the buyer's responsibility.

Pertanyaan yang Sering Diajukan

Apa spesifikasi MERSEN Fuse TRS6/10R?

MERSEN Fuse TRS6/10R adalah sekering Class RK5 tipe TRS-R Series dengan spesifikasi: tegangan AC 600 V, tegangan DC 600 V, arus 600 mA, time-delay, dan non-indicating. Produk ini memiliki part number TRS6/10R dan dirancang untuk aplikasi proteksi sirkuit industri.

Untuk apa MERSEN Fuse Class RK5 digunakan?

MERSEN Fuse Class RK5 tipe TRS-R Series digunakan sebagai pengaman arus lebih pada sirkuit listrik industri, seperti panel kontrol, motor, dan peralatan pembakaran. Sifat time-delay-nya memungkinkan sekering menahan lonjakan arus sesaat tanpa putus, cocok untuk beban induktif.

Apa perbedaan MERSEN TRS-R Series dengan sekering biasa?

MERSEN TRS-R Series adalah sekering Class RK5 dengan karakteristik time-delay, artinya dapat menahan arus lebih sementara (misalnya saat start motor) tanpa putus, berbeda dengan sekering fast-acting yang langsung putus. Produk ini juga memiliki rating tegangan AC dan DC hingga 600 V serta arus 600 mA.

Digunakan dalam

Aplikasi umum untuk MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Produk

3G Electric memasok MERSEN time-delay cylindrical fuses. We supply genuine products and their technical documentation.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran →Pompa & Kompresor →Suku Cadang →Semua Produk →

Lainnya dari MERSEN

Lihat semua MERSEN suku cadang →
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
MERSEN
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
MERSEN
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
Time-delay cylindrical fuse rated 1 A, 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inrush currents, such as motors and control circuits
MERSEN
Time-delay cylindrical fuse rated 1 A, 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inrush currents, such as motors and control circuits
MERSEN TRM Series midget time-delay fuse, rated 3.2 A and 250 V AC, with a 13/32 in x 1 1/2 in body size. Non-indicating type. Suitable for protecting control circuits, motors, and transformers where temporary inrush currents occur
MERSEN
MERSEN TRM Series midget time-delay fuse, rated 3.2 A and 250 V AC, with a 13/32 in x 1 1/2 in body size. Non-indicating type. Suitable for protecting control circuits, motors, and transformers where temporary inrush currents occur
Time-delay cylindrical fuse rated 7 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits subject to inrush currents, such as those with motors, transformers, or control panels
MERSEN
Time-delay cylindrical fuse rated 7 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits subject to inrush currents, such as those with motors, transformers, or control panels
Time-delay cylindrical fuse rated 10 A, 250 V AC, with dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits requiring tolerance to temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN
Time-delay cylindrical fuse rated 10 A, 250 V AC, with dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits requiring tolerance to temporary inrush currents, such as control panels, motor circuits, and power supplies
Class RK5 time-delay cylindrical fuse rated 1 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristics for motor and transformer protection. Suitable for overcurrent protection in industrial power distribution circuits
MERSEN
Class RK5 time-delay cylindrical fuse rated 1 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristics for motor and transformer protection. Suitable for overcurrent protection in industrial power distribution circuits
Midget, time-delay cylindrical fuse rated 5 A, 500 V AC. Body size 13/32 in x 1 1/2 in, non-indicating. Used in control panels, motor starters, and lighting systems to protect against overloads and short circuits where inrush currents occur
MERSEN
Midget, time-delay cylindrical fuse rated 5 A, 500 V AC. Body size 13/32 in x 1 1/2 in, non-indicating. Used in control panels, motor starters, and lighting systems to protect against overloads and short circuits where inrush currents occur