Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K - Thermocouples with Pipe Connection
ASHCROFTThermocouples with Pipe Connection

ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K

ASHCROFT Thermocouple Probe dengan tipe K adalah termokopel industri yang dirancang untuk pengukuran suhu ekstrem dari -328°F hingga 1,832°F (-200°C hingga 1,000°C). Probe ini memiliki panjang 16,73 inci dengan…

SKU 3G-OTH-201341

Merek
ASHCROFT
Item
Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K
Kategori
Thermocouples with Pipe Connection
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

ASHCROFT
Manufacturer Part Number
S50JTKN113N2-XU-J7R3-N120LN425
Type
±2.2°C, Type K
Probe Lg
16.73 in
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

ASHCROFT Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

ASHCROFT Thermocouple Probe dengan tipe K adalah termokopel industri yang dirancang untuk pengukuran suhu ekstrem dari -328°F hingga 1,832°F (-200°C hingga 1,000°C). Probe ini memiliki panjang 16,73 inci dengan akurasi ±2,2°C, ideal untuk aplikasi pembakar industri dan ketel uap yang memerlukan pemantauan suhu presisi. Sebagai termokopel dengan sambungan pipa, produk ini cocok untuk pemasangan tetap di berbagai peralatan pembakaran.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi ASHCROFT Thermocouple Probe tipe K?

ASHCROFT Thermocouple Probe ini adalah termokopel tipe K dengan rentang suhu -328°F hingga 1,832°F (-200°C hingga 1,000°C). Akurasi yang diberikan adalah ±2,2°C, dengan panjang probe 16,73 inci. Nomor komponennya adalah S50JTKN113N2-XU-J7R3-N120LN425.

Untuk apa ASHCROFT Thermocouple Probe digunakan?

Termokopel ini digunakan untuk mengukur suhu pada pembakar industri, ketel uap, dan sistem pembakaran lainnya yang memerlukan pemantauan suhu tinggi hingga 1,000°C. Dengan tipe K dan akurasi ±2,2°C, probe ini cocok untuk aplikasi kontrol proses di pabrik kelapa sawit, semen, dan industri makanan-minuman.

Di mana beli ASHCROFT Thermocouple Probe di Indonesia?

Anda dapat membeli ASHCROFT Thermocouple Probe melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi industri Anda.

Bagaimana cara memilih termokopel yang tepat untuk pembakar industri?

Pilih termokopel dengan rentang suhu yang sesuai dengan aplikasi Anda. ASHCROFT Thermocouple Probe tipe K ini mencakup -200°C hingga 1,000°C dengan akurasi ±2,2°C, cocok untuk suhu tinggi. Pastikan panjang probe (16,73 inci) dan jenis sambungan pipa sesuai dengan kebutuhan pemasangan Anda.

Digunakan dalam

Aplikasi umum untuk ASHCROFT
Process control in chemical plants — ASHCROFT G2 series pressure transmitters with 4-20 mA output
Sanitary monitoring in food processing — ASHCROFT sanitary pressure transmitters with stainless steel fittings
Temperature measurement in oil and gas — ASHCROFT flanged thermowells rated to 1,000°F
Hydraulic system pressure monitoring — ASHCROFT G2 series transmitters with 1-5 V DC output
Hazardous location pressure sensing — ASHCROFT A2X explosion-proof transmitters with conduit connection
Steam system temperature protection — ASHCROFT threaded thermowells rated to 7,000 psi

ASHCROFT Produk

3G Electric memasok ASHCROFT thermocouples with pipe connection. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.

Lainnya dari ASHCROFT

Lihat semua ASHCROFT suku cadang
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 28.74 in Probe Lg (MPN S50JTJN111N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 28.74 in Probe Lg (MPN S50JTJN111N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 28.74 in Probe Lg (MPN S50DTTN111F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 28.74 in Probe Lg (MPN S50DTTN111F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50STJN111N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50STJN111N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50DTJN111F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50DTJN111F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.