Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

BUSSMANN GMC-600-R Time-Delay Cylindrical Fuse, 600 mA, 250 V AC, 5 mm x 20 mm - Time-Delay Cylindrical Fuses
BUSSMANNTime-Delay Cylindrical Fuses

BUSSMANN GMC-600-R Time-Delay Cylindrical Fuse, 600 mA, 250 V AC, 5 mm x 20 mm

BUSSMANN GMC Series adalah sekering tipe time-delay (tunda waktu) berukuran 5 mm x 20 mm dengan rating 600 mA dan 250 V AC. Sekering ini dirancang untuk memberikan perlindungan tunda waktu pada rangkaian listrik…

SKU 3G-OTH-27662

Juga terdaftar sebagai: GMC600R · GMC 600 R

Merek
BUSSMANN
Item
GMC-600-R Time-Delay Cylindrical Fuse, 600 mA, 250 V AC, 5 mm x 20 mm
Kategori
Time-Delay Cylindrical Fuses
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

BUSSMANN
Manufacturer Part Number
GMC-600-R
Series
GMC

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

BUSSMANN Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

BUSSMANN GMC Series adalah sekering tipe time-delay (tunda waktu) berukuran 5 mm x 20 mm dengan rating 600 mA dan 250 V AC. Sekering ini dirancang untuk memberikan perlindungan tunda waktu pada rangkaian listrik industri, cocok untuk aplikasi yang memerlukan penanganan lonjakan arus sesaat tanpa trip prematur. Sebagai distributor resmi, 3G Electric menyediakan sekering BUSSMANN GMC-600-R untuk kebutuhan peralatan industri Anda di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi sekering BUSSMANN GMC-600-R?

Sekering BUSSMANN GMC-600-R memiliki spesifikasi: seri GMC, tipe time-delay, rating arus 600 mA, tegangan 250 V AC, dan ukuran fisik 5 mm x 20 mm. Sekering ini cocok untuk aplikasi proteksi tunda waktu pada rangkaian listrik.

Untuk apa sekering BUSSMANN GMC Series digunakan?

Sekering BUSSMANN GMC Series digunakan sebagai pengaman tunda waktu pada peralatan elektronik dan industri yang memerlukan perlindungan terhadap lonjakan arus sesaat, seperti pada catu daya, motor kecil, atau panel kontrol. Rating 600 mA dan 250 V AC membuatnya ideal untuk beban rendah.

Di mana beli sekering BUSSMANN GMC-600-R di Indonesia?

Anda dapat membeli sekering BUSSMANN GMC-600-R melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi Anda.

Bagaimana cara memilih sekering BUSSMANN yang tepat?

Pilih sekering BUSSMANN berdasarkan rating arus (600 mA), tegangan (250 V AC), dan tipe time-delay jika aplikasi Anda memiliki lonjakan arus sesaat. Pastikan ukuran fisik (5 mm x 20 mm) sesuai dengan holder sekering. Untuk GMC-600-R, pastikan kebutuhan Anda sesuai dengan spesifikasi tersebut.

Digunakan dalam

Aplikasi umum untuk BUSSMANN
Industrial motor control centers — BUSSMANN LPT series Class T time-delay fuses for branch circuit protection
Semiconductor protection in variable frequency drives — BUSSMANN FWA series fast-acting bolt-on fuses rated 150 V AC/DC
Automotive auxiliary circuit protection — BUSSMANN CB222 series Type II circuit breakers in 12 V DC systems
Control panel overcurrent protection — BUSSMANN FNA series midget time-delay indicating fuses for instrumentation
Main feeder protection in power distribution — BUSSMANN KLU series Class L time-delay bolt-on fuses up to 650 A
Fuse replacement in existing panels — BUSSMANN S-8301-1-R fuse block accepting 3AG and other glass/ceramic fuses

BUSSMANN Produk

3G Electric memasok BUSSMANN time-delay cylindrical fuses. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
The BUSSMANN GMC-80-R is a 5 mm x 20 mm time-delay cylindrical fuse rated at 80 mA and 250 V AC. It is used for overcurrent protection in industrial equipment, including control circuits, instrumentation, and power supplies where inrush currents are present
BUSSMANN
The BUSSMANN GMC-80-R is a 5 mm x 20 mm time-delay cylindrical fuse rated at 80 mA and 250 V AC. It is used for overcurrent protection in industrial equipment, including control circuits, instrumentation, and power supplies where inrush currents are present
Time-delay cylindrical fuse rated 63 mA at 250 V AC, with a 5 mm x 20 mm body. Designed for overcurrent protection in circuits where temporary inrush currents occur, such as control circuits, power supplies, and instrumentation
BUSSMANN
Time-delay cylindrical fuse rated 63 mA at 250 V AC, with a 5 mm x 20 mm body. Designed for overcurrent protection in circuits where temporary inrush currents occur, such as control circuits, power supplies, and instrumentation
BUSSMANN GMC Series time-delay cylindrical fuse rated 1.25 A at 250 V AC. The 5 mm x 20 mm form factor provides overcurrent protection in control panels, power supplies, and machinery where inrush currents require a delayed blow characteristic
BUSSMANN
BUSSMANN GMC Series time-delay cylindrical fuse rated 1.25 A at 250 V AC. The 5 mm x 20 mm form factor provides overcurrent protection in control panels, power supplies, and machinery where inrush currents require a delayed blow characteristic
The BUSSMANN GMC-6.3-R is a 6.3 A, 125 V AC time-delay cylindrical fuse in a 5 mm x 20 mm cartridge form factor. It is part of the GMC series and provides overcurrent protection for circuits with inrush currents, such as those found in motors and transformers
BUSSMANN
The BUSSMANN GMC-6.3-R is a 6.3 A, 125 V AC time-delay cylindrical fuse in a 5 mm x 20 mm cartridge form factor. It is part of the GMC series and provides overcurrent protection for circuits with inrush currents, such as those found in motors and transformers
The BUSSMANN GMD-600-R is a 5 mm x 20 mm time-delay cylindrical fuse rated at 600 mA and 250 V AC. It provides overcurrent protection in circuits subject to temporary inrush currents, such as those found in motor starters, power supplies, and lighting ballasts
BUSSMANN
The BUSSMANN GMD-600-R is a 5 mm x 20 mm time-delay cylindrical fuse rated at 600 mA and 250 V AC. It provides overcurrent protection in circuits subject to temporary inrush currents, such as those found in motor starters, power supplies, and lighting ballasts
Time-delay cylindrical fuse from the BUSSMANN GMD Series, rated 1.25 A and 250 V AC. Features a 5 mm x 20 mm form factor. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse from the BUSSMANN GMD Series, rated 1.25 A and 250 V AC. Features a 5 mm x 20 mm form factor. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents

Lainnya dari BUSSMANN

Lihat semua BUSSMANN suku cadang
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
BUSSMANN
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
BUSSMANN
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
BUSSMANN
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
BUSSMANN
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
BUSSMANN
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening