Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

BUSSMANN MDL-2-R Time-Delay Cylindrical Fuse, 2 A, 250 V AC, 1/4 in x 1 1/4 in - Time-Delay Cylindrical Fuses
BUSSMANNTime-Delay Cylindrical Fuses

BUSSMANN MDL-2-R Time-Delay Cylindrical Fuse, 2 A, 250 V AC, 1/4 in x 1 1/4 in

BUSSMANN Fuse seri MDL adalah sekering tipe time-delay (tunda waktu) berukuran silinder yang dirancang untuk aplikasi proteksi arus lebih pada peralatan industri. Sekering ini memiliki rating arus 2 A dan tegangan…

SKU 3G-OTH-26301

Juga terdaftar sebagai: MDL2R · MDL 2 R

Merek
BUSSMANN
Item
MDL-2-R Time-Delay Cylindrical Fuse, 2 A, 250 V AC, 1/4 in x 1 1/4 in
Kategori
Time-Delay Cylindrical Fuses
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

BUSSMANN
Manufacturer Part Number
MDL-2-R
Series
MDL

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

BUSSMANN Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

BUSSMANN Fuse seri MDL adalah sekering tipe time-delay (tunda waktu) berukuran silinder yang dirancang untuk aplikasi proteksi arus lebih pada peralatan industri. Sekering ini memiliki rating arus 2 A dan tegangan 250 V AC, dengan dimensi fisik 1/4 in x 1 1/4 in. Produk ini cocok digunakan sebagai pengaman pada rangkaian kontrol, panel distribusi, dan peralatan elektronik daya yang memerlukan karakteristik tunda waktu untuk menahan lonjakan arus sesaat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi sekering BUSSMANN MDL-2-R?

Sekering BUSSMANN MDL-2-R berfungsi sebagai pengaman arus lebih tipe time-delay. Dengan rating 2 A dan 250 V AC, sekering ini memberikan perlindungan pada peralatan industri terhadap hubung singkat dan beban lebih, sementara karakteristik tunda waktunya memungkinkan sekering tidak putus saat terjadi lonjakan arus sesaat yang wajar.

Apa spesifikasi teknis BUSSMANN MDL-2-R?

Spesifikasi teknis BUSSMANN MDL-2-R meliputi: seri MDL, tipe time-delay, rating arus 2 A, tegangan 250 V AC, dan ukuran fisik 1/4 in x 1 1/4 in. Sekering ini diproduksi oleh BUSSMANN dengan nomor part MDL-2-R.

Di mana beli BUSSMANN MDL-2-R di Indonesia?

Anda dapat membeli BUSSMANN MDL-2-R melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan sehingga Anda dapat menerima sekering BUSSMANN seri MDL dengan mudah untuk kebutuhan peralatan industri Anda.

Apa perbedaan sekering time-delay dengan sekering biasa?

Sekering time-delay seperti BUSSMANN MDL-2-R dirancang untuk menahan lonjakan arus sesaat (misalnya saat start motor atau kapasitor) tanpa putus, berbeda dengan sekering biasa yang langsung putus saat arus melebihi rating. Ini membuatnya ideal untuk aplikasi dengan beban induktif atau kapasitif.

Digunakan dalam

Aplikasi umum untuk BUSSMANN
Industrial motor control centers — BUSSMANN LPT series Class T time-delay fuses for branch circuit protection
Semiconductor protection in variable frequency drives — BUSSMANN FWA series fast-acting bolt-on fuses rated 150 V AC/DC
Automotive auxiliary circuit protection — BUSSMANN CB222 series Type II circuit breakers in 12 V DC systems
Control panel overcurrent protection — BUSSMANN FNA series midget time-delay indicating fuses for instrumentation
Main feeder protection in power distribution — BUSSMANN KLU series Class L time-delay bolt-on fuses up to 650 A
Fuse replacement in existing panels — BUSSMANN S-8301-1-R fuse block accepting 3AG and other glass/ceramic fuses

BUSSMANN Produk

3G Electric memasok BUSSMANN time-delay cylindrical fuses. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
The BUSSMANN MDL-1-R is a 1 A, 250 V AC time-delay cylindrical fuse from the MDL series. It features a 1/4 in x 1 1/4 in body and is designed to tolerate temporary inrush currents without nuisance opening. Typical applications include overcurrent protection in control panels, power supplies, and motor circuits
BUSSMANN
The BUSSMANN MDL-1-R is a 1 A, 250 V AC time-delay cylindrical fuse from the MDL series. It features a 1/4 in x 1 1/4 in body and is designed to tolerate temporary inrush currents without nuisance opening. Typical applications include overcurrent protection in control panels, power supplies, and motor circuits
Time-delay cylindrical fuse rated 250 mA, 250 V AC, with a 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents, suitable for use in control circuits, motor starters, and power supplies where short-duration overloads occur
BUSSMANN
Time-delay cylindrical fuse rated 250 mA, 250 V AC, with a 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents, suitable for use in control circuits, motor starters, and power supplies where short-duration overloads occur
Time-delay cylindrical fuse rated 1.5 A, 250 V AC, with 1/4 in x 1 1/4 in dimensions. Designed for overcurrent protection in circuits with moderate inrush currents, such as motors, transformers, and control panels
BUSSMANN
Time-delay cylindrical fuse rated 1.5 A, 250 V AC, with 1/4 in x 1 1/4 in dimensions. Designed for overcurrent protection in circuits with moderate inrush currents, such as motors, transformers, and control panels
Time-delay cylindrical fuse rated 500 mA, 250 V AC, with a 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents, it is used in circuits where short-duration surges occur, such as in control panels, motor circuits, and power supplies
BUSSMANN
Time-delay cylindrical fuse rated 500 mA, 250 V AC, with a 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents, it is used in circuits where short-duration surges occur, such as in control panels, motor circuits, and power supplies
Time-delay cylindrical fuse from the BUSSMANN MDL series, rated 4 A at 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse from the BUSSMANN MDL series, rated 4 A at 250 V AC. Measures 1/4 in x 1 1/4 in. Provides overcurrent protection for circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
Time-delay cylindrical fuse rated 3 A at 250 V AC, with 1/4 in x 1 1/4 in dimensions. Provides overcurrent protection for circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse rated 3 A at 250 V AC, with 1/4 in x 1 1/4 in dimensions. Provides overcurrent protection for circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents

Lainnya dari BUSSMANN

Lihat semua BUSSMANN suku cadang
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
BUSSMANN
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
BUSSMANN
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
BUSSMANN
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
BUSSMANN
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
BUSSMANN
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening