Konten Lembar Data
PRODUCT DATA SHEET
LINESHOT ™
AC Drain Line Flush Device
Description
Lineshot is a A/C drain line flush use to clean condensate drain lines fast. The Lineshot Device
features a tapered fitting that is compatible with 3/8" – 3/4" drain openings along with a flexible
hose for easy maneuverability. The product is lightweight and portable, which helps the technician
save time on service calls and eliminates the need to haul heavy tanks into the attic. This product
is compatible with the All-Access AA1 Cleanout Device.
Directions
RectorSeal Lineshot AC Drain Line Flush Device can be used individually or with
RectorSeal All-Access® AA1 Cleanout Device.
When using the device directly on pipes ranging from 3/8"-3/4"
1. Ensure red safety lock is on (pushed up)
2. Unscrew the body of the device, and insert RectorSeal Lineshot CO2 Cartridge (sold separately) with Characteristics | Features
narrow end facing up
• Lightweight
3. Carefully screw the body into the head of the device, ensuring that the cartridge is properly punctured • Portable
NOTE: Completely screw-in the unit to prevent leaking gas
• Environmentally-Friendly
4. Push the red safety catch down
5. Place the end of hose with black nozzle at the desired location
6. Press the trigger to discharge the CO2 to clear the clogged area
When using the device with All-Access AA1 Cleanout Device
1. Ensure red safety lock is on (pushed up)
2. Unscrew the body of the device, and insert RectorSeal Lineshot CO2 Cartridge with narrow end facing
up
3. Carefully screw the body into the head of the device, ensuring that the cartridge is properly punctured
NOTE: Completely screw-in the unit to prevent leaking gas
4. Insert the tapered nozzle into the All Access adapter OR insert the hose fitting into the Schrader valve
5. Push the red safety catch down
6. Press the trigger to discharge the CO2 through All-Access AA1 Cleanout Device
Packaging
Code Size Qty. per Case Lbs. per Case Cubic Feet
81980 AC Drain Line Flush Device 6 6 0.18
81981 CO 2 Refill Cartridges 6 8 0.16
Page 1 of 2
LINESHOT ™
AC Drain Line Flush Device
WARNING!
CARBON DIOXIDE 100%, 124-38-9. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED. MAY DISPLACE OXYGEN AND
CAUSE RAPID SUFFOCATION. MAY INCREASE RESPIRATION AND HEART RATE. PROTECT FROM SUNLIGHT. STORE IN WELL
VENTILATED PLACE.
FOR CHEMICAL EMERGENCY, SPILL, LEAK, FIRE, EXPOSURE OR ACCIDENT, CALL CHEMTREC-DAY OR NIGHT 1-800-424-9300.
Do not open Lineshot until cartridge is empty or injury may occur. Completely discharge cartridge before opening. Do not discharge towards face or body. KEEP OUT OF REACH OF
CHILDREN. FOR CONDENSATE DRAIN LINE CLEANING ONLY.
Limited Warranty
RectorSeal, LLC makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects. THIS LIMITED EXPRESS
WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER
OBLIGATION ON THE PART OF RectorSeal, LLC. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and disclaimed, and RectorSeal,
LLC shall not be liable for incidental or consequential damages.
RectorSeal , LLC 2601 Spenwick Drive, Houston, TX 77055, USA 800-231-3345 Fax 800-441-0051 rectorseal.com
A CSW Industrials Company. RectorSeal, the logos and other trademarks are property of RectorSeal, LLC, its affiliates or its licensor’s and are protected by copyright, trademark and other intellectual property laws, and may
not be used without permission. RectorSeal reserves the right to change specifications without prior notice. ©2019 RectorSeal. All rights reserved. R50420-0719
Made In China
Page 2 of 2
3G-CBM-01033
LineShot™
maintenance / réparation
Système de rinçage de conduite de vidange AC
Rinçage de conduite de vidange AC
Dégage rapidement les conduites d'évacuation des condensats
• Léger
• Portable
• Ecologique
LineShot™ Dispositif de dégagement de conduite de condensat AC
Applications
Code Description Qté
Dégage les canalisations facilement
81980 Dispositif de conduite de vidange 6 et rapidement avec un jet de CO2
81981 Cartouches de recharge de co2 6
• Comprend un raccord d'extrémité compatible
avec les vannes Schrader et un raccord
CARACTERISTIQUES
conique pour 3/8" – Ouverture de vidange 3/4"
• Poids léger
• Portable • Le tuyau flexible est facile à manoeuvrer dans
• Ecologique les espaces étroits
• Raccord conique compatible avec
les ouvertures de vidange de 3/8'' • Peut être utilisé avec le dispositif de nettoyage
All-Access® AA1.
à 3/4''
• Tuyau flexible pour une Recommandé pour
maniabilité aisée Conduites d'évacuation des condensats
RectorSeal® 2601 Spenwick Drive - Houston, TX 77055 800-231-3345 rectorseal.com
CSW, une société industrielle. Les logos et autres marques commerciales RectorSeal sont la propriété de RectorSeal, LLC, de ses filiales ou de son concédant de
licence, sont protégés par ses droits d'auteur, les marques commerciales et autres lois sur la propriété intellectuelle et ne peuvent pas être utilisés sans autorisation.
RectorSeal se réserve le droit de modifier les spécifications sans préavis. ©2019 RectorSeal. tous droits réservés. R50420-0819
LineShot™
AC Drain Line Flush System
Clears condensate drain lines fast
• Lightweight
• Portable
• Environmentally-Friendly
LineShot™ AC condensate line clearing device
Code Description Qty Applications
81980 Drain Line Device 6 Clears drain lines quickly and easily
81981 Co2 Refill Cartridges - 12ea. 6
with a burst of CO2 • Includes an end
fitting compatible with Schrader
valves and a tapered fitting for 3/8"
FEATURES – 3/4" drain openings • Flexible hose
• Lightweight is easy to maneuver in tight spaces •
• Portable Can be used with the All-Access® AA1
• Environmentally-Friendly Cleanout Device.
• Tapered fitting that is compatible
with 3/8" – 3/4" drain openings Recommended for
• Flexible hose for easy Condensate Drain Lines
maneuverability
RectorSeal® 2601 Spenwick Drive - Houston, TX 77055 800-231-3345 rectorseal.com
A CSW Industrials Company. RectorSeal, the logos and other trademarks are property of RectorSeal, LLC, its affiliates or its licensor’s and are protected by copyright, trademark
and other intellectual property laws, and may not be used without permission. RectorSeal reserves the right to change specifications without prior notice. ©2019 RectorSeal. All