Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
CBMHVAC & Refrigeration

CBM Regulator Leak Lock 39 ml

CBM Leak Lock adalah sealant pipa dan ulir (pipe joint sealant) dalam kemasan 39 ml yang diformulasikan khusus untuk sistem pendingin udara (Air Conditioning). Produk ini berfungsi sebagai pengganti gasket dan…

SKU 3G-CBM-01051

Juga terdaftar sebagai: CLI 05202 · CLI-05202

Merek
CBM
Item
Regulator Leak Lock 39 ml
Kategori
HVAC & Refrigeration
UNSPSC
40101701 — Air conditioners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
volume ml
39
product type
sealant
classification
flammable

Konten Lembar Data

Page 1/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 30.10.2012 Revision: 30.10.2012 1 Identification of the substance/mixture and of the company/undertaking · 1.1 Product identifier · Trade name: LEAK LOCK · Article number: 10001, 10004, 10016, 10128 · 1.2 Relevant identified uses of the substance or mixture and uses advised against No further relevant information available. · Application of the substance / the preparation Pipe joint sealant, Gasket seal, Threadlocker · 1.3 Details of the supplier of the Safety Data Sheet · Manufacturer/Supplier: Highside Chemicals, Inc. 11114 Reichold Road Gulfport, MS 39503 Phone: (228) 896-9220 · Further information obtainable from: Product Safety Department · 1.4 Emergency telephone number: ChemTel Inc. (800)255-3924, +1 (813)248-0585 2 Hazards identification · 2.1 Classification of the substance or mixture · Classification according to Regulation (EC) No 1272/2008 GHS02 flame Flam. Liq. 2 H225 Highly flammable liquid and vapour. · Classification according to Directive 67/548/EEC or Directive 1999/45/EC F; Highly flammable R11: Highly flammable. · Information concerning particular hazards for human and environment: The product has to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. · Classification system: The classification is according to the latest editions of the EU-lists, and extended by company and literature data. The classification is in accordance with the latest editions of international substances lists, and is supplemented by information from technical literature and by information provided by the company. · 2.2 Label elements · Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation. (Contd. on page 2) 35.0.37 Page 2/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 30.10.2012 Revision: 30.10.2012 Trade name: LEAK LOCK (Contd. of page 1) · Hazard pictograms GHS02 · Signal word Danger · Hazard-determining components of labelling: titanium dioxide · Hazard statements H225 Highly flammable liquid and vapour. · Precautionary statements P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read label before use. P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P241 Use explosion-proof electrical/ventilating/lighting/equipment. P280 Wear protective gloves/protective clothing/eye protection/face protection. P281 Use personal protective equipment as required. P240 Ground/bond container and receiving equipment. P233 Keep container tightly closed. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. P308+P313 IF exposed or concerned: Get medical advice/attention. P370+P378 In case of fire: Use for extinction: CO2, powder or water spray. P405 Store locked up. P403+P235 Store in a well-ventilated place. Keep cool. P501 Dispose of contents/container in accordance with local/regional/national/international regulations. · Hazard description: · WHMIS-symbols: B2 - Flammable liquid D2B - Toxic material causing other toxic effects · NFPA ratings (scale 0 - 4) Health = 2 3 Fire = 3 2 0 Reactivity = 0 (Contd. on page 3) 35.0.37 Page 3/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 30.10.2012 Revision: 30.10.2012 Trade name: LEAK LOCK (Contd. of page 2) · HMIS-ratings (scale 0 - 4) HEALTH *2 Health = *2 FIRE 3 Fire = 3 REACTIVITY 0 Reactivity = 0 * - Indicates a long term health hazard from repeated or prolonged exposures. · HMIS Long Term Health Hazard Substances 64-17-5 ethanol 13463-67-7 titanium dioxide · 2.3 Other hazards · Results of PBT and vPvB assessment · PBT: Not applicable. · vPvB: Not applicable. 3 Composition/information on ingredients · 3.2 Mixtures · Description: Mixture of substances listed below with nonhazardous additions. · Dangerous components: CAS: 64-17-5 ethanol 25-50% EINECS: 200-578-6 F R11 Index number: 603-002-00-5 Flam. Liq. 2, H225 CAS: 13463-67-7 titanium dioxide < 10% EINECS: 236-675-5 Xn R20-40 Carc. Cat. 3 Carc. 2, H351 Acute Tox. 4, H332 CAS: 57-55-6 Propylene Glycol < 10% EINECS: 200-338-0 substance with a Community workplace exposure limit · Additional information: For the wording of the listed risk phrases refer to section 16. 4 First aid measures · 4.1 Description of first aid measures · General information: No special measures required. · After inhalation: Supply fresh air; consult doctor in case of complaints. · After skin contact: Clean with water and soap. If skin irritation continues, consult a doctor. · After eye contact: Rinse opened eye for several minutes under running water. Remove contact lenses if worn. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. (Contd. on page 4) 35.0.37 Page 4/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 30.10.2012 Revision: 30.10.2012 Trade name: LEAK LOCK (Contd. of page 3) · After swallowing: Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately. · 4.2 Most important symptoms and effects, both acute and delayed Dizziness Gastric or intestinal disorders · Hazards No further relevant information available. · 4.3 Indication of any immediate medical attention and special treatment needed If swallowed, gastric irrigation with added, activated carbon. Monitor circulation, possible shock treatment. Medical supervision for at least 48 hours. 5 Firefighting measures · 5.1 Extinguishing media · Suitable extinguishing agents: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. · For safety reasons unsuitable extinguishing agents: None. · 5.2 Special hazards arising from the substance or mixture In case of fire, the following can be released: Carbon monoxide (CO) Under certain fire conditions, traces of other toxic gases cannot be excluded. · 5.3 Advice for firefighters · Protective equipment: Wear self-contained respiratory protective device. Wear fully protective suit. · Additional information Cool endangered receptacles with water spray. 6 Accidental release measures · 6.1 Personal precautions, protective equipment and emergency procedures Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation Keep away from ignition sources. Protect from heat. · 6.2 Environmental precautions: Dilute with plenty of water. · 6.3 Methods and material for containment and cleaning up: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose contaminated material as waste according to item 13. · 6.4 Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information. (Contd. on page 5) 35.0.37…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

CBM Leak Lock adalah sealant pipa dan ulir (pipe joint sealant) dalam kemasan 39 ml yang diformulasikan khusus untuk sistem pendingin udara (Air Conditioning). Produk ini berfungsi sebagai pengganti gasket dan pengunci ulir (threadlocker) pada sambungan refrigeran. Perhatikan bahwa Leak Lock diklasifikasikan sebagai cairan yang sangat mudah terbakar (Highly flammable liquid and vapour - H225), sehingga penanganan dan penyimpanannya harus sesuai dengan petunjuk keselamatan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa CBM Leak Lock 39 ml digunakan?

CBM Leak Lock 39 ml digunakan sebagai sealant sambungan pipa (pipe joint sealant), pengganti gasket (gasket seal), dan pengunci ulir (threadlocker) pada sistem pendingin udara (Air Conditioning). Produk ini dirancang untuk menyegel sambungan refrigeran agar tidak bocor.

Apa spesifikasi CBM Leak Lock 39 ml?

CBM Leak Lock memiliki volume 39 ml dan diklasifikasikan sebagai cairan yang sangat mudah terbakar (Flam. Liq. 2, H225). Produk ini adalah sealant untuk sambungan pipa dan ulir pada sistem pendingin udara. Kode artikel yang terkait termasuk 10001, 10004, 10016, dan 10128.

Apakah CBM Leak Lock aman digunakan pada sistem AC?

Ya, CBM Leak Lock diformulasikan khusus untuk aplikasi sistem pendingin udara sebagai pipe joint sealant dan threadlocker. Namun, karena produk ini sangat mudah terbakar (H225), Anda harus mengikuti petunjuk keselamatan pada lembar data keselamatan (SDS) dan menghindari sumber api saat penggunaan.

Di mana beli CBM Leak Lock 39 ml di Indonesia?

Anda dapat membeli CBM Leak Lock 39 ml melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM hvac & refrigeration. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Leak Lock teflon 39 ml
C21-013 reservoir
CBM
C21-013 reservoir
Siphon
CBM
Siphon
Non-return valve
CBM
Non-return valve
CBM
CBM
Reduction 18mm
CBM
CBM
Reduction 20mm

Lainnya dari CBM

Lihat semua CBM suku cadang
Shock absorber support 700
CBM
Shock absorber support 700
CBM
CBM
Black coupling 80mm
CBM
CBM
Tube cutter 1/8 - 3/4
CBM
CBM
Vacuum pump pressure gauge vertical
CBM
CBM
Cable gland M20 for proximity switch
CBM
CBM
Set of 4 extensions 130 mm
CBM
CBM
71L/min battery vacuum pump
CBM
CBM
Black vertical right angle 80mm