Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Appion Digital vacuum gauge BluVac - Air Conditioning
AppionAir Conditioning

Appion Digital vacuum gauge BluVac

Appion BluVac LTE adalah pengukur vakum digital presisi tinggi yang dirancang untuk teknisi HVAC/R profesional. Dengan rentang pengukuran 0 hingga 25.000 Mikron dan resolusi hingga 0,1 Mikron, alat ini mampu…

SKU 3G-CBM-01085

Juga terdaftar sebagai: CLI 20214 · CLI-20214

Merek
Appion
Item
Digital vacuum gauge BluVac
Kategori
Air Conditioning
UNSPSC
40101701 — Air conditioners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Appion
type
Digital vacuum gauge
model
BluVac LTE
range
0 to 25,000 Microns
display
Large back-lit LCD
resolution
1 Micron
wireless range
100m line-of-sight
measurement units
Microns, Pascals, Millibar, Millitorr, mmHg
vacuum port fitting
¼" Male Flare
maximum overpressure
1,000 PSI
operating temperature
-12°C to 50°C

Konten Lembar Data

BluVac Digital Vacuum Gauge User’s Guide AccuTools® is a registered trademark of Core Enterprises, Inc. P/N 10525-01 Rev. C BluVac User’s Guide Introduction Thank you for your purchase of the AccuTools® BluVac Digital Vacuum Gauge. The BluVac is the most accurate and precise vacuum gauge available today with patent-pending technology that cannot be found anywhere else. With the BluVac, you can accurately measure vacuum pressure in Microns, Pascals, Millibar, Millitorr, and mmHg with resolution down to 0.1 micron. Ideal for the HVAC/R professional, the BluVac is small, lightweight, rugged and easy to use. It is programmable, and allows for unattended evacuation of HVAC/R systems of all sizes. Features • Large, high-visibility back-lit LCD display • Measures Vacuum in Microns, Pascals, Millibar, Millitorr and mmHg • 0 to 25,000 Micron Range with 0.1 Micron Resolution less than 10,000 Microns • “Analog” Vacuum Level Bar Graph • Vacuum Leak Rate and Ambient Temperature Indicator • Automatic Oil Sensor • Measures Temperature in Fahrenheit and Celsius to 0.1° • Built-in memory retains all previous settings • Rugged, Compact Design – About the Size of a Manifold Gauge • Long Battery Life • Programmable • Calibration Self Test -- Can be field calibrated with no special equipment • Ideal for HVAC/R Service and Industrial Use Specifications Range: 0 – 25,000 Microns (3333.1 Pa, 33.331 mBar, 25,000 mTorr, 25.000 mmHg) Vacuum Accuracy: 5% of Reading +/- 5 Microns Vacuum Resolution: 0.1 Micron (@ 0.0 to 9999.9 Microns) Temperature Accuracy: 0.2°F (0.1°C) Temperature Resolution: 0.1° Warm-up Time: Instant Response Time: Instant Power: 9V Alkaline Battery (9V Lithium recommended for low temperature operation) Battery Life: Up to 300 Hours Operating Temperature: 10°F – 122°F (-12°C – 50°C) Vacuum Port Fitting: ¼” Male Flare – Nickel Plated for Durability with Dust Cap Weight: 6 oz. (170g) including Battery and Swivel Hook Dimensions: 3.5” x 3” x 1.25” (9cm x 7.5cm x 3cm) WARNING: To avoid personal injury and to prevent damage to the BluVac Digital Vacuum Gauge, never exceed 500 PSI. 1 BluVac User’s Guide Parts Diagram 2 BluVac User’s Guide LCD Display Item Function A Main Numeric Display B Alternate Numeric Display C “Analog” Vacuum Level Bar Graph Backlight Indicator. Flashing: Temporary, Solid: Always On Sound Indicator Battery Level Indicator Set Mode Indicator Run Mode Indicator Run Mode Complete Indicator Oil Sensor Indicator Calibration Mode Indicator Indicates that Time is Displayed on the Alternate Numeric Display Indicates that Temperature is Displayed on the Alternate Numeric Display Indicates that the Vacuum Leak Rate is Displayed on the Alternate Numeric Display Indicates either Celsius or Fahrenheit Degrees are Displayed Indicates that the Vacuum Leak Rate is Displayed in UNITS/second. Pascal Units Indicator Millibar Units Indicator Millitorr Units Indicator Millimeters of Mercury Units Indicator Micron Units Indicator 3 BluVac User’s Guide Keypad Item Function Press to Turn Power On, Press and Hold to Turn Power Off Press and Release to Change Display Units Press and Hold to Change Temperature Display Units (°F or °C) Press and Release to Enter RUN Mode Press and Hold to Cancel RUN Mode Press to Switch Between Temperature Display and Leak Rate Display Press and Release to Activate Backlight Press or Press and Hold to Change Programmed Pressure or Time in SET mode Press and Hold to Enter SET Mode Press and Release to Switch to Next Setting Press and Hold to Exit SET Mode Press and Hold to Mute/Un-mute Sound Quick Start To operate the BluVac as a basic vacuum gauge: 1. Install the battery as described in the “Battery Installation” section below. 2. Turn the power on by pressing . The display will show to indicate pressure greater than 25,000 Microns. 3. Select the desired units by repeatedly pressing . 4. Attach the BluVac to the system to be evacuated with a high quality vacuum hose. Start the vacuum pump. Read the vacuum level from the Main Display. 5. Turn the power off by pressing and holding . WARNING: To avoid damaging the BluVac, only hand-tighten sensor connection. If greater torque is required, support the sensor housing with a ¾” wrench. NOTE: To assist in the use of this gauge and the interpretation of vacuum information, please refer to the Frequently Asked Questions Section at the end of this guide. 4 BluVac User’s Guide Battery Installation & Replacement 1. Remove the battery cover from the rear of the BluVac by compressing tab at the base of the battery cover. 2. If necessary, remove and detach old battery from battery clip. 3. Attach battery clip to new battery and insert into battery compartment. Replace battery cover by aligning tab and snapping back into place. IMPORTANT: TO PREVENT DAMAGE FROM LEAKING BATTERIES, DO NOT LEAVE A DEAD BATTERY INSIDE THE BluVac. REMOVE BATTERY IF THE BluVac IS NOT TO BE USED FOR AN EXTENDED PERIOD OF TIME. Battery Level Indicator The battery level indicator shows the relative strength of the battery. Full power is indicated by four bars. As the battery is depleted, the number of bars displayed decreases, until no bars are left. At this point, it is necessary to replace the batteries (refer to the Battery Installation section above). If the battery power drops to the point where the BluVac can no longer function accurately, the alarm will beep 10 times and the power will turn off automatically. When the battery is replaced, and the BluVac is turned back on, the BluVac will resume operation with all previous setting intact. Hi-Pressure Indication If the sensed vacuum pressure exceeds 25,000 Microns (3333.1 Pa, 33.331 mBar, 25,000 mTorr, or 25.000 mmHg), the display will show . Sleep Mode Unlike other Digital Vacuum Gauges, the BluVac helps to conserve battery life through advanced power management. After 5 minutes of displaying , the BluVac will enter “Sleep Mode” in which the sensor and backlight are turned off, thus reducing the load on the battery and extending the battery life up to 300 hours or more. While in this mode, the display will show . Approximately every 35 seconds, the gauge will automatically check the pressure and exit Sleep Mode if the pressure is less than 25,000 Microns. The gauge can be manually brought out of Sleep Mode by pressing any key on the keypad. While in Sleep, the gauge will beep twice every 5 minutes to remind you that it is on. The BluVac will not sleep in the Set Mode or the Calibration Mode (see the corresponding sections below). Auto Power-Off After 1 hour in “Sleep Mode” the BluVac will automatically turn itself off to further conserve battery power. Oil Sensor It is necessary to prevent oil from being drawn into the Vacuum Sensor. For HVAC/R service, always recover refrigerant prior to attaching gauge. If possible, always close the blank-off valve on the vacuum pump prior to turning the vacuum pump off. Over time, oil vapor and other materials may contaminate the sensor. The BluVac has a built in Oil Sensor that will detect this condition. If the OIL indicator on the display illuminates, this is an indication that the vacuum sensor has been contaminated and is no longer functioning accurately. If the sensor becomes completely saturated with oil to the extent that it cannot function properly at all, the message will show on the 5 BluVac User’s Guide display. Prior to further use of the BluVac, clean the sensor as describe in the “Cleaning the Vacuum Sensor” section below. Units Change the displayed units by pressing and releasing the key on the keypad. The appropriate units indicator on the LCD display will show Pa, mBar, mTorr, mmHg, or Microns depending on the units set. The units cannot be changed in the Set Mode or the Run Mode (see corresponding sections below). Range and Resolution The BluVac has a broad vacuum pressure measurement range, and the highest resolution of any gauge. The display range and resolution depends upon the units displayed and the vacuum pressure reading, according to the table below: Vacuum Vacuum Pressure Range Reading Resolution 1,000.0 — 3,333.1 0.1 Pa Pascals (Pa) 0 — 3,333.1 0 — 999.99 0.01 Pa 10.000 — 33.331 0.001 mBar Millibar (mBar) 0 — 33.331 0 — 9.9999 0.0001 mBar 10,000 — 25,000 1 mTorr Millitorr (mTorr) 0 — 25,000 0 — 9,999.9 0.1 mTorr 10.000 — 25.000 0.001 mmHg mmHg (mmHg) 0 — 25.000 0 — 9.9999 0.0001 mmHg 10,000 — 25,000 1 Micron Microns (Microns) 0 — 25,000 0 — 9,999.9 0.1 Micron “Analog” Vacuum Level Bar Graph The BluVac also displays a Vacuum Level Bar Graph allowing for a quick visual determination of the vacuum level achieved. Each bar corresponds to a vacuum pressure range depending on units according to the following table: Units Bar Value Microns Pa Millibar Millitorr mmHg 10K 10,000 — ATM 1,000 — ATM 10 — ATM 10,000 — ATM 10 — ATM 5K 5,000 — 10,000 500 — 1,000 5 — 10 5,000 — 10,000 5 — 10 2K 2,000 — 5,000 200 — 500 2—5 2,000 — 5,000 2—5 1K 1,000 — 2,000 100 — 200 1—2 1,000 — 2,000 1—2 500 500 — 1,000 50 — 100 0.5 — 1 500 — 1,000 0.5 — 1 200 200 — 500 20 — 50 0.2 — 0.5 200 — 500 0.2 — 0.5 100 100 — 200 10 — 20 0.1 — 0.2 100 — 200 0.1 — 0.2 50 50 — 100 5 — 10 0.05 — 0.1 50 — 100 0.05 — 0.1 20 20 — 50 2—5 0.02 — 0.05 20…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Appion Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Appion BluVac LTE adalah pengukur vakum digital presisi tinggi yang dirancang untuk teknisi HVAC/R profesional. Dengan rentang pengukuran 0 hingga 25.000 Mikron dan resolusi hingga 0,1 Mikron, alat ini mampu menampilkan satuan Mikron, Pascal, Millibar, Millitorr, dan mmHg pada layar LCD besar dengan lampu latar. Dilengkapi koneksi port vakum ¼" Male Flare dan ketahanan tekanan berlebih maksimum 1.000 PSI, BluVac LTE sangat ideal untuk proses evakuasi sistem AC dan refrigerasi yang membutuhkan akurasi tinggi.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Appion BluVac LTE?

Appion BluVac LTE adalah pengukur vakum digital yang digunakan untuk mengukur tekanan vakum pada sistem HVAC/R. Alat ini menampilkan nilai vakum dalam satuan Mikron, Pascal, Millibar, Millitorr, dan mmHg dengan resolusi hingga 0,1 Mikron, sehingga sangat membantu dalam proses evakuasi sistem pendingin dan ketel uap.

Apa spesifikasi teknis Appion BluVac LTE?

Spesifikasi Appion BluVac LTE meliputi rentang pengukuran 0 hingga 25.000 Mikron, resolusi 0,1 Mikron, akurasi vakum 5% of Reading +/- 5 Mikron, port vakum ¼" Male Flare, tekanan berlebih maksimum 1.000 PSI, dan suhu operasi -12°C hingga 50°C. Alat ini menggunakan baterai 9V dengan daya tahan hingga 300 jam.

Di mana beli Appion BluVac LTE di Indonesia?

Anda dapat membeli Appion BluVac LTE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga produk sampai ke lokasi Anda dengan aman. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih pengukur vakum digital yang tepat?

Pilih pengukur vakum digital seperti Appion BluVac LTE yang memiliki rentang pengukuran sesuai kebutuhan, misalnya 0 hingga 25.000 Mikron. Perhatikan resolusi (0,1 Mikron), akurasi, dan koneksi port (¼" Male Flare). Pastikan juga alat tahan terhadap tekanan berlebih maksimum 1.000 PSI dan memiliki layar yang mudah dibaca.

Apakah Appion BluVac LTE bisa digunakan untuk sistem refrigerasi industri?

Ya, Appion BluVac LTE dirancang untuk HVAC/R profesional dan cocok untuk evakuasi sistem refrigerasi industri. Dengan rentang 0 hingga 25.000 Mikron dan resolusi tinggi, alat ini memastikan proses vakum berjalan akurat. Fitur seperti indikator laju kebocoran vakum dan sensor oli otomatis sangat membantu dalam aplikasi industri.

Digunakan dalam

Aplikasi umum untuk Appion
Commercial air-conditioning commissioning — Appion WS260 scale and AV760 vacuum gauge for system charge verification and evacuation testing
Refrigerant recovery and containment — Appion recovery hoses (MH380004AAY, MH380006AAY) and service tees (CTEE14) for EPA-compliant recovery workflows
Industrial refrigeration maintenance — Appion manifold components (VFL90L swivel fittings, service tees) for diagnostic branching without system isolation
Vacuum pump servicing — Appion KTMV25 seal kits for in-place rebuild of recovery equipment compressors
Portable HVAC diagnostics — Appion digital vacuum gauge (AV760) and Bluetooth scale (WS260) for field-portable measurement and data logging
Compressor replacement and rebuild — Appion KTG520-R joint kits for quick-connect coupling on oil-injected compressor units

Appion Produk

3G Electric memasok Appion air conditioning. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Digital vacuum gauge
Appion
Appion
Digital vacuum gauge AV760 high precision
Digital vacuum gauge VG64
Supco
Digital vacuum gauge VG64
CBM
CBM
Vacuum pump pressure gauge vertical
Vacuum pump gauge axial 1/8"
CBM
Vacuum pump gauge axial 1/8"
Vacuum gauge VG 640
Supco
Vacuum gauge VG 640

Lainnya dari Appion

Lihat semua Appion suku cadang
Appion
Appion
BluVac LTE digital vacuum gauge
BluVac + Pro Bluetooth digital vacuum gauge
Appion
BluVac + Pro Bluetooth digital vacuum gauge
Vacuum gauge BluVac + Micro
Appion
Vacuum gauge BluVac + Micro