Pompa peristaltik CBM PE 5000 dirancang khusus untuk membuang air kondensat pada sistem pendingin udara (AC) dengan kapasitas hingga 8 kW. Dengan flow rate 6 l/jam dan kemampuan discharge head maksimal 12 meter…

SKU 3G-CBM-01114

Juga terdaftar sebagai: CLI 50020 · CLI-50020

Merek
CBM
Item
Peristaltic pump PE 5000 compressor
Kategori
HVAC & Refrigeration
UNSPSC
40101701 — Air conditioners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
flow rate
6 l/h
application
up to 8 kW AC
inlet diameter
15 mm
outlet diameter
6 mm
power cable length
1.7 m
degree of protection
IP65
max height discharge
12 m

Konten Lembar Data

PE 5000 - PE 5100 - PE 5200 Cod. 0000136282 Instruction Manual Manuel D’Instruction Manuale Istruzioni Manual de Instrucciones Handbuch руководство по эксплуатации Parc d'Activités de l'Orée de Chevry - Route de Férolles - 77173 CHEVRY-COSSIGNY Tel: (+33) 01 60 62 06 06 - fax: (+33) 01 60 62 09 09 http://www.sauermann.fr - e.mail: info@sauermann.fr English The PE range of Peristaltic pumps are designed to remove condensate water. They are particularly adapted for use in Air Conditioning, Evaporator & Refrigerated cabinet applications. Characteristics:  Flow 6 l/h  Max Discharge Head.: 12 m  Max Suction Height: 2 m  Power Supply: 230 V~ - 50/60 Hz  Motor Power Level: 11 W  IP 65  Max Design Ambient Temperature: 50° C 0. SECURITY 0.1 In any case PE series peristaltic pumps have not to run continuously 0.2 Sauermann recommends to use a security system (Floating alarm ACC00601 NO/NC 10 Amp – 230 Vac (optional; see fig.8) or similar) allowing to stop the unit and prevent the overflowing whenever an excessive amount of condensate is produced. The PE 5200 pump is equipped with a NC 8 Amp – 250 V contact allowing this function. 0.3 Sauermann does not accept any responsibility in case of not respect of these recommendation 1. INSTALLATION Warning: Before carrying out any operation on the pump, make sure the installation is disconnected from the power supply. We recommend the pump be positioned with the suction & discharge spigots pointing downward.  Installation with Mounting Bracket supplied (fig. 1) - Fasten the Mounting Bracket with the screw & rawlplug supplied. - Slide the pump body onto the bracket. 2. POWER SUPPLY (fig. 2 and 4) 2.1 Connection to power supply Connect the pump to the power supply using a circuit breaker (not included) to standard IEC 345 on live & neutral. 2.2 Connection for model PE 5000 (Cooling only, compressor signal) (fig. 2) Connect the black cable to one of the supply phases of the compressor power supply (see fig.2) or of the three-way valve (chilled water applications) in order to start the pump whenever the air- handling unit is in cooling mode. The presence of a 230 V supply on the black cable starts the pump. When the compressor stops, the voltage drops to zero. The pump continues to operate for 3 minutes on overrun and stops. In any case the black cable have not to be direct connected before the power switch. Otherwise the pump will run continuously (see chapter 0). 2.3 Connection for model PE 5100 (Heat-pump, temperature differential sensors) see (fig. 3) Position Blue sensor cable to air-off side of the air handling unit & the Red sensor cable on the return-air side. The pump operates as soon as a temperature difference of 6°C +/- 2°C is sensed. It will continue to operate as long as the temperature difference sensed is greater than 6°C +/- 2°C. When the temperature difference sensed drops below 6°C +/- 2°C, the pump will continue to operate on overrun for 3 minutes before stopping. Warning: Temperature sensors must absolutely be placed into the air flow (Red: suction; Blue: delivery) and never placed either in the condensate water or the condensate tray or in the false ceiling for any reason. Otherwise the pump could run continuously (see chapter 0). 2.4 Connection for model PE 5200 (General Use, Remote Float Sensor) (see fig. 4) Connect the interconnecting cable from the remote float sensor to the pump body. The remote float sensor senses the presence of condensate & can start / stop the pump & send an alarm signal if it detects an abnormal amount in the sump. Important: The alarm provided is an 8A/250V resistive NC contact. This can be used to stop the cooling cycle if an abnormal amount of condensate is detected & reduce the possibility of overflow accidents. Please consult & follow the air conditioning manufacturers electrical diagram & alarm connection recommendations at all times. 3. CONDENSATE CONNECTIONS 3.1 For models PE 5000 & PE 5100 (see fig. 2 and 3) Condensate Removal The suction end of the pump must be connected to the condensate tray fall pipe with the rubber adapter tube, reducer adaptor & clear tube supplied. The suction tube must be securely connected to the suction side of the pump (see Δ mark on cover plate) with the tie wraps supplied. 3.2 For model PE 5200 (see fig. 4) a) Condensate Removal The remote float detection unit must be connected to the condensate tray fall pipe with the rubber adapter supplied. b) Remote Float Detection Unit The suction end of the pump (see Δ mark on cover plate) must be connected to one of the two possible 7 mm connections on the remote float detection unit with clear 6 mm int. diam. tubing. The unused 7 mm connection on the float detection unit must be capped with the cap provided. c) Breather Tube The 4 mm diam. breather tube supplied must be connected to the top of the float detection unit such that the top of the free end of the tube is situated above the edge of the condensate tray. d) Installation Important: Install the float detection unit in a level attitude to ensure correct operation of the float (see fig.5). 3.3 Condensate Removal Pipe The 6 mm diam. (1/4 inch braided or clear) condensate removal pipe must be securely connected to the discharge side of the pump (see exit mark ∇ on cover) with the tie wraps provided (see fig 2, 3 & 4). The waste end of the condensate removal pipe must terminate in an approved drain or waste water fall tube & may be connected to it with the Sauermann ACC00205 self-sealing fitting (not provided). 4. POST-INSTALLATION OPERATION TEST 4.1 For models PE 5000 & PE 5100 Start the air conditioning unit & pour a small amount of water into the condensate tray using the Sauermann ACC00401 priming squeeze bottle (not included) or other means. Check that the pump is operating correctly & removing water from the tray by pressing the Test button situated on the side of the pump (see Fig.6). The pump will operate on overrun for three minutes & stop if correctly installed. 4.2 For model PE 5200 Pour a small amount of water into the condensate tray using the Sauermann ACC00401 priming squeeze bottle (not included). Check that the pump is operating correctly & removing water from the tray. If correctly installed, the pump should stop when the water level has decreased. To check Alarm function, continue to pour water into the tray until the float rises sufficiently to trigger your chosen alarm feature (switch off compressor, visual or audible alarm…). This will depend on individual Installer preferences. 5. CLEANING & MAINTENANCE WARNING: Before any intervention, switch off pump power supply at source. 5.1 Cleaning of remote detection unit for model PE 5200 The float detection unit & filter must be cleaned regularly with due regard to the prevailing levels & types of pollution in the operating environment of the unit. Proceed as follows: - Remove the cover from the detection unit body. - Remove the metallic filter. - Clean the detection unit & the filter body with a solution of water 5% bleach. - Replace the filter & firmly replace the cover on the detection unit body. Important: We recommend that after every service, the pump operation & alarm features should be tested as in Para 4 above to ensure serviceability. 5.2 Replacing worn pump head tube Regularly inspect pump head tube & replace every 12 months or as required depending on the operating environment of the pump. Warning: Be sure to disconnect the pump from the power supply to ensure it cannot start & potentially injure the engineer while the tube is being replaced. 5.2.1 Removal of pump head tube - Disconnect the suction & waste tubes from the pump - Remove the cover plate - Rotate the roller assembly manually into a vertical position - Remove the suction side connector from its housing by pulling upwards - Keep pulling the tube upwards & remove it by rotating the roller assembly clockwise. - The waste side connector can now be removed from its housing & the tube has successfully been removed. 5.2.2 Fitting the replacement pump head tube (see fig.7) - Insert the suction side (left hand) connector into its housing & place the tube in position with one hand. Rotate the roller assembly clockwise until the tube is seated correctly and insert the waste side (right hand) connector in its housing. - Replace the protective cover plate in position. - Note: Always test the pump after any intervention to ensure serviceability. 6. WARRANTY 6.1 Sauermann warranty for these products is 2 years from date of delivery. The warranty is strictly limited to the replacement or remanufacture of those parts that are defective or show defects in production. No other warranty is offered either explicitly or implicitly in respect of any other matter whatsoever. 6.2 Entire pumps, pump heads or components returned under warranty must be complete & accompanied by a note detailing the installation date, address & the defect observed by the engineer. 6.3 This warranty is not related to the membrane tube 6.4 We decline any responsibility whatsoever for pump failures in case of incorrect installation, not respect of these recommendations, poor or incorrect cleaning & maintenance or non- connection of an alarm contacts (ACC00601, optional) to prevent overflow in case of problems in removing condensate. Français Les pompes péristaltiques série PE sont destinées à relever des condensats. Elles sont particulièrement adaptées aux climatiseurs, évaporateurs, vitrines réfrigérées… Caractéristiques:  Débit 6 l/h  Refoulement max.: 12 m  Aspiration max: 2 m  Tension 230 V~ - 50/60 Hz  Puissance du moteur: 11 W  IP 65  Température ambiante max: 50° C 0. SECURITE 0.1 Les Pompes Péristaltiques de la série PE ne doivent en aucun cas fonctionner en continu. 0.2 Sauermann préconise l'utilisation d'un système de sécurité (Flotteur Alarme ACC00601 NO/NC 10 Amp – 230 Vac (en option; fig. 8) ou autre), afin de stopper la production de froid et prévenir ainsi le débordement du bac en cas d'afflux trop important de condensats. La pompe PE 5200 est équipée d'un contact NC 8 Amp – 250 V permettant cette fonction. 0.3 Sauermann décline toute responsabilité en cas de non respect de ces spécifications. 1. INSTALLATION Avertissement: avant toute intervention, mettre impérativement l’installation hors tension Fixer la pompe avec les raccords faisant face vers le bas.…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pompa peristaltik CBM PE 5000 dirancang khusus untuk membuang air kondensat pada sistem pendingin udara (AC) dengan kapasitas hingga 8 kW. Dengan flow rate 6 l/jam dan kemampuan discharge head maksimal 12 meter, pompa ini sangat cocok untuk aplikasi AC split, evaporator, dan lemari pendingin. Dilengkapi dengan tingkat perlindungan IP65, pompa ini memastikan keandalan operasional di lingkungan industri yang menuntut. Cari suku cadang AC atau pompa kondensat untuk kebutuhan Anda? Produk ini adalah solusi yang tepat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa pompa peristaltik CBM PE 5000 digunakan?

Pompa peristaltik CBM PE 5000 digunakan untuk membuang air kondensat yang dihasilkan oleh unit AC, evaporator, dan lemari pendingin. Pompa ini dirancang untuk aplikasi dengan kapasitas hingga 8 kW AC dan memiliki flow rate 6 l/jam serta max discharge head 12 m.

Apa spesifikasi teknis pompa kondensat CBM PE 5000?

Spesifikasi teknis CBM PE 5000 meliputi flow rate 6 l/jam, max discharge head 12 m, diameter inlet 15 mm, diameter outlet 6 mm, panjang kabel daya 1,7 m, dan tingkat perlindungan IP65. Pompa ini menggunakan catu daya 230 V~ 50/60 Hz dengan konsumsi daya motor 11 W.

Bagaimana cara memasang pompa peristaltik CBM PE 5000?

Pasang bracket pemasangan yang disertakan ke dinding menggunakan sekrup dan rawlplug. Kemudian, selipkan badan pompa ke bracket. Pastikan spigot hisap dan buang mengarah ke bawah. Sebelum melakukan instalasi, pastikan instalasi listrik telah diputus dari catu daya.

Di mana beli pompa CBM PE 5000 di Indonesia?

Anda dapat membeli pompa peristaltik CBM PE 5000 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Apa fungsi kabel hitam pada pompa CBM PE 5000?

Pada model PE 5000 (hanya untuk pendinginan, sinyal kompresor), kabel hitam dihubungkan ke salah satu fase suplai kompresor. Ini memungkinkan pompa menyala hanya saat kompresor AC beroperasi, mengoptimalkan pembuangan kondensat.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM hvac & refrigeration. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pratissoli
Pratissoli
POMPA MW250 1500 D5V
Pratissoli
Pratissoli
PUMP MK265 1500 D5V
Pratissoli
Pratissoli
PUMP MF75M-75-DISC 500 D1V
Pratissoli
Pratissoli
POMPA MW245 1500 D5V
Pratissoli
Pratissoli
POMPA MX250 1500 D5V
Pratissoli
Pratissoli
POMPA MW250 1800 D5V

Lainnya dari CBM

Lihat semua CBM suku cadang
Shock absorber support 700
CBM
Shock absorber support 700
CBM
CBM
Black coupling 80mm
CBM
CBM
Tube cutter 1/8 - 3/4
CBM
CBM
Vacuum pump pressure gauge vertical
CBM
CBM
Cable gland M20 for proximity switch
CBM
CBM
Set of 4 extensions 130 mm
CBM
CBM
71L/min battery vacuum pump
CBM
CBM
Black vertical right angle 80mm