Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Delta Universal Biofuel pump - Oil Pumps
DeltaOil Pumps

Delta Universal Biofuel pump

Pompa bahan bakar universal Delta VU/BVU adalah unit bahan bakar universal yang dirancang untuk pembakar industri minyak. Pompa ini memiliki tegangan 230 VAC 50/60Hz, tekanan setting 10 ±0,3 bar, dan kecepatan…

SKU 3G-CBM-01884

Juga terdaftar sebagai: DEL 02006 · DEL-02006

Merek
Delta
Item
Universal Biofuel pump
Kategori
Oil Pumps
UNSPSC
40151524 — Oil pumps
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Delta
voltage
230 VAC 50/60Hz
strainer
Nylon mesh 150µ
nozzle port
G1/8
hub diameter
Ø32
rotation speed
3500 rpm max
shaft diameter
Ø8
solenoid power
9 W
pressure setting
10 ±0.3 bar
inlet return connection
G1/4

Konten Lembar Data

deltapumps.com VU BVU Universal fuel unit for oil burners DE115-0613 Universal fuel unit for oil burners Type VU, BVU 1- Applications The DELTA Universal fuel unit is an efficient and modern oil burner pump. Since its mounting flange, hub and shaft sizes are manufactured to international standards (EN 225-1), it can be fitted to every type of high pressure oil burner or transfer pump applications. Its features allow an easy pump replacement with every other type of oil pump. The same unit is provided with bilateral nozzle ports and is suitable for both clockwise and counter clockwise rotation. WARNING For the use with low viscosity fuel (lower than 2.5cSt, i.e. Kerosene) standard pump can be used without exceeding 12 bar. To pump biodiesel or fuel containing it in any percentage, it is necessary the “B” version with special seals. On request the pump can be provided free of nonferrous metals. This unit must not be used to pump water or acid. 2- Operation The VU fuel unit consists of a pump, solenoid valve, filter and pressure regulator valve (1) housed within one casting. The pumping action is obtained from two spur gears, one of which is connected to the drive shaft (3). The pump casting provides the various oil ways, for the suction (6), return (5) and nozzle ports (9). Pressure (8) and vacuum (7) gauge ports are also provided. Under the vacuum gauge is located the rotation From the suction side, the gears pass the oil to the selector (2). See the Installation and Service Section. pressure chamber, where it comes up against the head of the piston. Due to the build up of pressure, the piston The VU unit is supplied in two pipe version (self priming). is forced back against the pressure regulating spring. On start up, the rotating gears purge the air from the The flow of pressurized oil is interrupted by an suction chamber, through a vent groove in the piston to incorporated solenoid valve, and can, therefore, be the return line in two pipe version, and through the opened following the start of the motor (pre-purge), or nozzle line (after the solenoid valve opening) in one pipe interrupted before stopping the motor itself (instant shut- version. off of the flame preventing the nozzle dripping). The On initial commissioning, it is possible to bleed the air excessive oil discharges to the return side (or by-passes more quickly, through the pressure gauge port. in the one pipe version). It will be realized of course that the spring tension, which is varied by the regulator Because a vacuum now exists oil, due to atmospheric screw, regulates the pressure of oil required. pressure, enters the suction chamber through the filter. The pump can be converted from the two pipe version to the single pipe version, removing the by-pass plug (4) from the return port. When the unit is converted to the single pipe version, on initial commissioning the air must be bled through the pressure gauge port (in this case lift installation are not recommended). 2-6 3- Pump identification VU 1 L R 2 FA Pump type VU = standard version BVU = biodiesel version (explicit request for nonferrous metals absence) Nozzle capacity (see graph) Rotation - factory setting (seen from shaft end) R = clockwise L = counter clockwise Nozzle line open - factory setting (seen from cover) R = right L = left Pipes system - factory setting 1 = one pipe 2 = two pipes Coil type FA = NF84 230VAC 50/60Hz FC = NF84 24VAC 50/60Hz (coil with connector plug and cable set) 4- Technical specifications Oil viscosity …………………………………. 1,2 ÷ 12 cSt Oil temperature ……………………………... 60°C max. Power consumption ………………………... See graphs Nozzle capacity ……………………………... See graphs Pressure range …………………………….... 6 ÷ 18 bar Suction line vacuum ……………………….. 0,5 bar max. Suction line pressure ……………….……... 2 bar max. Return line pressure ……………………….. 2 bar max. Starting torque ……………………………… 0,1 Nm max. Rotation speed ……………..………….……. 3500 rpm max. Standard strainer……….….………………... Nylon mesh 150µ, 20cm² Dimensions (EN 225-1) …………………….. Hub Ø32, shaft Ø8 Connections (ISO 228-1) …………………... Inlet – Return : G1/4 Nozzle port : G1/8 Pressure – vacuum gauge : G1/8 Weight ……………………………………….. 1050 g Standard factory settings ………………… Pressure setting: 10 ±0,3 bar Standard coil: 230 VAC 50/60Hz Standard cable set: 3 cores, 700 mm 5- Solenoid valve specifications Power absorbed .……………………………. 9 W Voltage tolerance …………………………… -15% / +10% Ambient temperature .……………………... 0°C / 60°C Operating pressure ……………………….... 25 bar max. Flow factor (VDI/VDE 2173) ……………….. 0,059 m3/h Cut-off pressure …………………………….. 6 bar Approval (EN ISO 23553-1) ……………….. DIN CERTCO Reg.-Nr. 5S102/09 3-6 6- Diagrams Nozzle capacity Power consumption 7- Overall dimensions 1 Pressure regulation 7 Vacuum gauge 2 Rotation selector 8 Pressure gauge 3 Shaft sealing 9 Nozzle ports 4 By pass 10 Solenoid valve 5 Return 6 Suction 4-6 8- Bypass installation To convert the DELTA fuel unit from the two pipe version to the single pipe version, do the following: a) Using a 4 mm Allen key, unscrew the bypass plug from the return port (Fig. 1). b) Fit a 1/4" plug into the return port (Fig. 2). WARNING In the two pipe version the air is bled through the return port. After conversion, the air must be bled manually, through the pressure gauge port. Make sure that the by-pass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and Fig. 3 burner motor could result. 9- Selection of rotation The VU unit is provided with a screw for the selection of rotation, located under the vacuum gauge plug (V). To change the direction of rotation do the following: a) Using a screw driver, remove the 1/8" plug from vacuum gauge port. Under the plug, inside the pump, is the selector screw. NOZZLE NOZZLE P VU1 L V b) Turn it 90° up to the stop, to change the rotati on UNIVERSAL FUE INLET Made Paten (Fig. 3). TV20 UN After conversion, check the O-ring is located on the bottom of the vacuum port and replace the 1/8" plug. Fig. 1 Fig. 4 Clockwise Counter Clockwise (seen from shaft end) (seen from shaft end) NOZZLE NOZZLE L R P VU1 V UNIVERSAL FUEL UNIT Made in Italy INLET RETURN Patent pending TV2000U000022 UN L IV ERSA WARNING Fig. 2 The selection screw must be oriented with the groove vertical (L) or horizontal (R), otherwise the fuel unit will not function properly and damage could 19 result (Fig.4). 5-6 10- Installation and Maintenance 12- Nozzle Cut-Off Test 1. Make sure that the by-pass plug is not used in a single pipe Fuel oil is not compressible but air is. Air trapped in the nozzle installation, because the fuel unit will not function properly and line, anywhere between the fuel units nozzle port and the damage to the pump and burner motor could result. nozzle itself, will compress during burner operation. Following 2. The rotation selector must be oriented with the groove burner shutdown, any trapped compressed air will expand vertical (L) or horizontal (R). displacing the oil in the nozzle line, forcing continued oil flow 3. Do not use fuel with additives to avoid the possible formation through the nozzle that will, in effect, falsely appear to be poor over time of compounds which may deposit between the gear fuel unit Cut-Off. This occurrence is particularly common with teeth, thus obstructing them. low flow rate nozzles used in conjunction with long air tubes. 4. After filling the tank, wait before starting the burner. This will To verify positive nozzle Cut-Off after burner shutdown, do the give any suspended impurities time to deposit on the bottom of following: the tank, thus avoiding the possibility that they might be sucked into the pump.…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Delta Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pompa bahan bakar universal Delta VU/BVU adalah unit bahan bakar universal yang dirancang untuk pembakar industri minyak. Pompa ini memiliki tegangan 230 VAC 50/60Hz, tekanan setting 10 ±0,3 bar, dan kecepatan putaran maksimal 3500 rpm. Dilengkapi dengan saringan nilon mesh 150µ, katup solenoida 9 W, serta koneksi inlet/return G1/4 dan port nozzle G1/8. Pompa ini cocok untuk berbagai aplikasi pembakar bertekanan tinggi dan tersedia dalam versi 'B' dengan seal khusus untuk biodiesel.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa pompa Delta VU/BVU digunakan?

Pompa Delta VU/BVU digunakan sebagai unit bahan bakar universal untuk pembakar industri minyak, khususnya pada sistem pembakar bertekanan tinggi. Pompa ini dapat menggantikan berbagai merek pompa minyak lainnya berkat dimensi flange, hub, dan shaft yang sesuai standar internasional EN 225-1.

Apa spesifikasi teknis pompa Delta VU/BVU?

Spesifikasi pompa Delta VU/BVU meliputi tegangan 230 VAC 50/60Hz, tekanan setting 10 ±0,3 bar, kecepatan putaran maksimal 3500 rpm, daya solenoida 9 W, diameter shaft Ø8, diameter hub Ø32, koneksi inlet/return G1/4, port nozzle G1/8, dan saringan nilon mesh 150µ.

Apakah pompa Delta VU/BVU bisa digunakan untuk biodiesel?

Ya, pompa Delta VU/BVU tersedia dalam versi 'B' yang dilengkapi seal khusus untuk memompa biodiesel atau bahan bakar yang mengandung biodiesel dalam persentase berapa pun. Versi standar hanya cocok untuk bahan bakar dengan viskositas di atas 2,5 cSt.

Di mana beli pompa Delta VU/BVU di Indonesia?

Anda dapat membeli pompa Delta VU/BVU melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih pompa Delta VU/BVU yang tepat?

Pilih pompa Delta VU/BVU berdasarkan jenis bahan bakar yang digunakan. Untuk minyak tanah atau solar, gunakan versi standar. Untuk biodiesel, pilih versi 'B' dengan seal khusus. Pastikan juga tegangan 230 VAC 50/60Hz dan tekanan setting 10 ±0,3 bar sesuai kebutuhan sistem Anda.

Digunakan dalam

Aplikasi umum untuk Delta
Oil burner heating systems — Delta VM1 and VM2 fuel unit pumps delivering 35–55 l/h at 20 bar pressure setting
Industrial lubrication circuits — Delta A-series and A2-series pumps with 130 µm stainless steel strainers at 10 bar pressure
Hydraulic equipment integration — Delta AD-series pumps rated 3500 rpm with 32 mm hub diameter for modular system assembly
Burner nozzle supply — Delta fuel units with G1/8" nozzle port and solenoid valve integration for atomization control
Replacement pump specification — Delta cable assemblies (700 mm, 3-core) for retrofit and maintenance of existing burner equipment
Multi-stage heating plant operation — Delta VM2 models with 150 µm nylon filtration for continuous-duty burner fuel supply

Delta Produk

3G Electric memasok Delta oil pumps. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Aksesori Pompa Katup & Regulasi Motor & Penggerak Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Universal pump VU1
Delta
Universal pump VU1
Pump AD1 L2
Delta
Pump AD1 L2
Pump V1 LR 2.4
Delta
Pump V1 LR 2.4
Pump V1LR 2P
Delta
Pump V1LR 2P
Pump V1RL 2P
Delta
Pump V1RL 2P
Pump V5 RR 2.4
Delta
Pump V5 RR 2.4

Lainnya dari Delta

Lihat semua Delta suku cadang
Delta
Delta
VM3 LL 2.4 pump
Delta
Delta
Cover joint V
Delta
Delta
Pump VM1 LL 2.4 2P
Delta
Delta
Sieve S
Delta
Delta
Universal pump VU2
Delta
Delta
Pump VM3 RL 2.4
Delta
Delta
24 V coil for VU1
Delta
Delta
Cap + seal for pump filter (type A)