Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
CBMAccessories & Installation

CBM Loading and washing pump SUPERFLUK

Pompa loading dan washing CBM SUPERFLUK adalah peralatan pembersih dan descaling yang dirancang khusus untuk perawatan ketel uap industri. Dengan kapasitas reservoir 30 liter, laju aliran 30 L/menit, tekanan maksimal…

SKU 3G-CBM-01946

Juga terdaftar sebagai: DET 10017 · DET-10017

Merek
CBM
Item
Loading and washing pump SUPERFLUK
Kategori
Accessories & Installation
UNSPSC
47131821 — Degreasing compounds
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
dimensions
98
heating coil w
2000
flow rate l min
30
pressure max bar
5
reservoir liters
30
max temperature c
90

Konten Lembar Data

PROF 02 User’s manual - Use and Maintenance E Descaling pumps Dear Customer, thank you for choosing a EUROACQUE Pump. MANUAL This manual is a safe guide for the use of the pump. Please read it carefully in all its parts before use. This manual contains important information for the proper working and use of the equipment. EUROACQUE reserve the right to introduce any future changes without notice or replacement. PRELIMINARY INSPECTION Upon receipt of the pump, take it out from the carton and check it is in perfect condition. Also check that the data on the rating plate correspond to required ones. For any problem, immediately contact the supplier specifying the kind of fault. In case of doubts about the safety of the machine, do not use it. DESCRIPTION The pump SUPERFLUK is fitted with built-in heater and flow reverser. Particularly recommended for difficult descaling treatments, they work in complete safety and autonomy enabling the operator to carry out other works at the same time. Pumps with tank for descaling boilers by using specific acid based restoring products. The pumps are equipped with special fittings and valves to adjust the flows and purge the sludge, built up by the operation, which is then rapidly removed. Pumps are supplied ready to use, in strong carton boxes with related user’s manual. CONTENTS 1 - REGULATIONS – CE MARK page 2 2 - THE ADVANTAGES OF THE PUMPS PROF 02 page 2 3 - TECHNICAL FEATURES page 3 4 - CUSTOMER SERVICE page 3 5 - USE page 3 6 - SAFETY INSTRUCTIONS page 4 7 - EXPLODED VIEWS page 5 8 - DIRECTIONS FOR DISPOSAL page 6 9 - WARRANTY TERMS AND AFTER-SALE ASSISTANCE CONDITIONS page 6 1 1 - REGULATIONS – CE MARK Declaration of Conformity The pumps are in conformity with the following European Directives, Laws and Regulations: Machinery Directive 2006/42/EC QUALITY EUROACQUE equipments are manufactured with high-quality acid-resistant materials and submitted to severe operating tests. Follow these instructions to avoid any operating and servicing problems. 2 - THE ADVANTAGES OF THE PUMP SUPERFLUK Time and, above all, temperature increase make calcium salts, usually present in water, precipitate in the Heat exchanger form of microcrystals and settle on metallic surfaces of pipes, plant coils and heat exchangers, thus reducing flow rate and thermal efficiency. To restore the original plant performance it is necessary to carry out a descaling with specific products and equipments. The built-in heater and flow reverser device attacks scale on both sides, thus making descaling particularly effective and fast (as the normal dissolving action is combined with the detachment in flakes of scale, which is made friable by the double attack), even when pipes and exchangers are almost totally obstructed. Thermo-Clean Clockwise Counterclockwise circulation circulation 2 3 - TECHNICAL FEATURES SUPERFLUK Motor 220V, 600W - HP 0,8 Max working pressure 6 Bar Degree of protection IPX4 Max. temperature 60° C Flow rate 50* l/min. ENGLISH Head 60m* Fittings 3/4” Tank capacity 35 l Heating coil 2000 w Flow Reverser Manual Dimensions HxWxD 65 x 35 x 40 cm Weight Kg 23 * Data referred to the pump body outlet. 4 - CUSTOMER SERVICE For enquiries on spare parts, please specify serial number of pump (shown on product and carton). 5 - USE 5.1 - HOW TO PREPARE THE PUMP AND CHECK THE SEAL - Fill the tank with enough water to ensure that the pump rotor housing is submerged during operation. - Screw the outer ends of the flexible hoses securely to the exchanger to be descaled. - Connect the power cable to a single-phase 220 V power supply. - Switch on the pump and check the seal of the hose fittings on the exchanger and on the pump. In case of leaks of liquid, check hoses and fittings and replace the defective components, if necessary. - When seal is safe, switch off the pump. FLOW RETURN FLOW RETURN - If necessary, add more descaling product by referring to the dilution specified in the data sheet of the product. 3 5.2 - FUNCTIONING Connect pump to the system. Ensure that valve is in the closed position. -Fill the tank with water. -Add cleaning chemical to the tank. -Turn on the heater. SUPERFLUK have automatic temperature controller on it. Heater automaticaly heats water up to 50° C in the tank. -Switch on the pump and clean the system. -Use flow reverser for efficient cleaning. The SUPERFLUK have 2 x 250 cm flow/return hoses fitted with 3/4” brass hose connectors at the out board end and 3/4” fittings at the inboard end. In cleaning process: The inboard end of both flow/return hoses should be screwed onto the corresponding ¾” brass nipples on rear of the hose support plate. The other ends of these hoses should be connected to the system (radiator/boiler/pump). In dumping process: Disconnect one of the flow/return hose screwed on rear of the hose support plate and lead it to a toilet pan or drain pipe g ully leading to a foul sewer. 5.3 - HOW TO CLEAN THE PUMP After descaling REMOVE THE DESCALING LIQUID FROM THE TANK and wash out the pump by circulating clean water through it for at least 10 minutes. ADD 200 cc. OF XS2 PRODUCT FOR THE MAINTENANCE AND CLEANING OF THE IMPELLER 6 - SAFETY INSTRUCTIONS - Avoid using the pump in rooms where there are liquids, gases, flammable powders or with risk of explosion. - Before plugging in the pump to the outlet, make sure the switch is off. - The outlet must be suitable for the plug of the pump. Do not use non CE-marked defective outlets. - Use (CE) approved extensions, only if necessary. - Do not use plug adapter. Do not carry out any modifications to the plug nor to the electrical cable. - Pump shall always kept in perfect efficiency. - During maintenance operations, check the switch is off and the plug is not connected. - All maintenance operations must be carried out by the authorized Technical Assistance Service. - Only use EUROACQUE original spare parts. - Do not carry out any modifications to the pump if not authorized by Technical Department (ask for written authorization). - Keep children and unauthorized persons away from the pump. - Keep the pump out of reach of children and unauthorized persons. - Do not use the pump if tired or under the effect of alcohol, medicines or drugs. - When using the pump, wear overalls, do not wear jewellery, keep hair away from the pump. - When handling descaling liquids, be very careful. It is necessary to use Individual Protection Equipment (IPE). 4 7 - EXPLODED VIEWS AND SPARES DIAGRAMS P.S..: For enquiries on spare parts, please specify always if needed for the model SUPERFLUK 1 3 2 15 16 17 4 5 9 11 13 18 6 19 20 10 12 21 14 7 25 26 8 22 27 23 28 24 29 1. Filter 10. Connection hose 1/2" 19. Electric cable 28. Electric cable 2. Tank 11. 2 way connector 3/4" 20. 4 way ball valve 29. Flow-return outlet 3/4" 3. Tank cap 12. Elbow 3/4" 21. Back&bottom metal panel 30. Heater switch on/off 4. Elbow 13. Pneumatic hose 22. Pressure indicator 31. 3/4” Pressure line 5. Thermostat 14. Pump 23. Flow reverser valve 32. Cap 6. Heating element 15. Heat meter 24. Flow-return outlet 3/4" 33. Heater switch on/off 7. Elbow 1/2" 16. Pump switch 25. Pump on/off switch 7. Temperature indicator 8. Wheel 17.Heater switch 26. Heater on/ff switch 8. 3/4” Return line 9. Connection hose 1/2" 18.Pressure gauge 27. Temperature indicator 9. Wheel 5 8 - DIRECTIONS FOR DISPOSAL In accordance with the WEEE directive 2002/96/EC on waste electrical and electronic equipment, the pump, when no longer used, shall be disposed of in a RAEE – WEEE collection centre authorized for disposal of waste electrical and electronic equipment, or directly contact your dealer. 9 - WARRANTY TERMS AND AFTER-SALE ASSISTANCE CONDITIONS EUROACQUE guarantee that the equipments sold are free from designing, manufacturing and material defects, under normal operating conditions and according to the directions contained in the instruc- tions manual supplied with the equipment. In compliance with the directive 1999/44/CE valid in the EEC countries, the warranty rights apply only to the purchaser. EUROACQUE guarantee the equipments against any conformity defects appearing within 12…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pompa loading dan washing CBM SUPERFLUK adalah peralatan pembersih dan descaling yang dirancang khusus untuk perawatan ketel uap industri. Dengan kapasitas reservoir 30 liter, laju aliran 30 L/menit, tekanan maksimal 5 bar, dan suhu maksimal 90 °C, pompa ini dilengkapi pemanas internal (2000 W) serta pembalik aliran untuk hasil descaling yang optimal. Cocok untuk aplikasi pembersihan kerak pada pembakar industri dan sistem ketel uap di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa pompa CBM SUPERFLUK digunakan?

Pompa CBM SUPERFLUK digunakan untuk membersihkan dan menghilangkan kerak (descaling) pada ketel uap dan peralatan pembakaran industri. Pompa ini bekerja dengan sirkulasi larutan asam khusus melalui sistem, memanfaatkan pemanas internal 2000 W dan pembalik aliran untuk membersihkan endapan secara efektif.

Apa spesifikasi teknis pompa CBM SUPERFLUK?

Spesifikasi pompa CBM SUPERFLUK meliputi: reservoir 30 liter, laju aliran 30 L/menit, tekanan maksimal 5 bar, suhu maksimal 90 °C, dan pemanas koil 2000 W. Dimensi unit adalah 98 mm (periksa manual untuk detail lengkap). Pompa ini dilengkapi fitting dan katup khusus untuk mengatur aliran dan membuang lumpur.

Di mana beli pompa CBM SUPERFLUK di Indonesia?

Anda dapat membeli pompa CBM SUPERFLUK melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih pompa descaling yang tepat untuk ketel uap?

Pilih pompa descaling seperti CBM SUPERFLUK berdasarkan kapasitas reservoir (30 liter), laju aliran (30 L/menit), tekanan maksimal (5 bar), dan suhu operasi (maks 90 °C). Pastikan pompa memiliki pemanas internal dan pembalik aliran untuk hasil optimal. Konsultasikan dengan teknisi untuk mencocokkan dengan kebutuhan ketel uap Anda.

Apakah pompa CBM SUPERFLUK aman digunakan untuk descaling?

Ya, pompa CBM SUPERFLUK dirancang dengan bahan tahan asam dan telah memenuhi standar CE (Machinery Directive 2006/42/EC). Pompa ini bekerja secara otonom dan aman, memungkinkan operator melakukan pekerjaan lain. Ikuti petunjuk keselamatan dalam manual untuk penggunaan yang benar.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM accessories & installation. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
40 L cart pump EUROMAX FLUSHTROLLEY
CBM
40 L cart pump EUROMAX FLUSHTROLLEY
CBM
CBM
System cleaning pump 30 L EURPRSPN
Rinsing pump EUROMAX120 EUROM120
CBM
Rinsing pump EUROMAX120 EUROM120
CBM
CBM
Kit and cartridges KIT/RIVER/ADD/L KITRADDL
Heating system water softener TROLLEY/AUTO ADTROLAU
CBM
Heating system water softener TROLLEY/AUTO ADTROLAU
Adapter kit type 1
CBM
Adapter kit type 1

Lainnya dari CBM

Lihat semua CBM suku cadang
CBM
CBM
PH calibration solution 25 sachets of 20ml
CBM
CBM
Test kit ALGOL 110 L TC000820
CBM
CBM
Descaler 40 EUROPR40
CBM
CBM
Iron test kit TC000800
CBM
CBM
Solution hardness test kit litered TC000TIT
CBM
CBM
Test kit Kit XS (1-2-3) TC000EXS
CBM
CBM
EUROOXY analysis test kit with strips (25 tests) KITOXYST
CBM
CBM
Joint removal tool