Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dwyer Pengukur aliran ultrasonik kompak UFM2-14 - Measurement
DwyerMeasurement

Dwyer Pengukur aliran ultrasonik kompak UFM2-14

Dwyer UFM2-14 adalah compact ultrasonic flow meter tipe clamp-on yang dirancang untuk pengukuran aliran non-invasif pada pipa. Alat ini kompatibel dengan material pipa seperti steel, stainless steel, copper, dan…

SKU 3G-CBM-02190

Juga terdaftar sebagai: DWY 18102 · DWY-18102

Merek
Dwyer
Item
Pengukur aliran ultrasonik kompak UFM2-14
Kategori
Measurement
UNSPSC
41112412 — Pressure gauge
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dwyer
power supply
12-24 VDC / 24 VAC
power consumption
7 W / 7 VA minimum
compatible materials
steel, stainless steel, copper, plastic
pipe internal diameter range
0.8" to 6.5" (20 mm to 165 mm)

Konten Lembar Data

UFM2/UBT UFM2: Clamp-on Ultrasonic Flow Meter UBT: Clamp-on Ultrasonic Heat Meter User Manual UBT shown DWYER INSTRUMENTS, INC. 102 INDIANA HWY 212 Phone: 219-879-8000 MICHIGAN CITY Fax: 219-872-9057 INDIANA 46360 Web: www.dwyer-inst.com USA Email: info@dwyer-inst.com Issue 1.1 UFM2/UBT User Manual CONTENTS 1 INTRODUCTION ....................................................................................... 1 1.1 General Description ............................................................................................................ 1 1.2 How Does It Work? ............................................................................................................. 2 1.3 Package Contents .............................................................................................................. 3 1.4 Display................................................................................................................................ 4 1.5 Quick Start Procedure ........................................................................................................ 5 2 INSTALLATION......................................................................................... 6 2.1 Identify Suitable Location .................................................................................................... 6 2.1.1 Additional Considerations for Locating UBT ................................................................. 6 2.1.2 Clean the Pipe’s Flow Sensor Contact Area ................................................................ 7 2.2 Connect Power and Signal Cables ..................................................................................... 7 2.2.1 Power Supply .............................................................................................................. 7 2.2.2 Pulse Output Connection ............................................................................................. 8 2.2.3 Current Output (UFM2 only) ........................................................................................ 8 2.2.4 Modbus Connections (if fitted) ..................................................................................... 8 2.2.5 Temperature Sensor Probes (UBT only) .................................................................... 10 2.3 Switch On ......................................................................................................................... 11 2.3.1 UFM2 ........................................................................................................................ 11 2.3.2 UBT ........................................................................................................................... 12 2.4 Adjust Flow Sensor Separation ......................................................................................... 13 2.5 Apply Gel Pads ................................................................................................................. 13 2.6 Clamp Sensor Assembly to Pipe....................................................................................... 14 2.6.1 Pipe Adaptors ............................................................................................................ 14 2.6.2 Attaching to Pipe ....................................................................................................... 15 2.7 Remove Sensor-Holding Screws ...................................................................................... 16 2.8 Connect Electronics Module ............................................................................................. 16 2.9 Attach the Temperature Sensors (UBT Only).................................................................... 17 2.10 Normal Operation ............................................................................................................. 18 2.10.1 UFM2 ........................................................................................................................ 18 2.10.2 UBT ........................................................................................................................... 18 2.10.3 Troubleshooting the Flow Reading ............................................................................ 19 2.11 Clip Electronics Module to Sensor Assembly .................................................................... 19 3 MENUS.................................................................................................... 20 3.1 Accessing the Menus........................................................................................................ 20 3.2 Setup Menu ...................................................................................................................... 21 3.3 Modbus Menu ................................................................................................................... 22 Issue 1.1b July 20 Page i UFM2/UBT User Manual 3.4 Current Output Menu (UFM2 only).................................................................................... 23 3.5 Pulse Output Menu ........................................................................................................... 24 3.6 Calibration Menu .............................................................................................................. 25 3.7 Volume Totals Menu ......................................................................................................... 26 3.8 Diagnostics Menu ............................................................................................................. 27 4 OUTPUTS ................................................................................................ 28 4.1 Pulse Output ..................................................................................................................... 28 4.1.1 Volumetric Pulse........................................................................................................ 28 4.1.2 Frequency Mode........................................................................................................ 29 4.1.3 Energy Pulse (UBT only) ........................................................................................... 29 4.1.4 Flow Alarm - Low Flow .............................................................................................. 29 4.1.5 Flow Alarm – Signal Loss .......................................................................................... 29 4.2 4-20 mA Current Output (UFM2 only, if fitted) ................................................................... 29 4.3 Modbus (if fitted) ............................................................................................................... 30 5 RELOCATING THE UNIT......................................................................... 33 6 APPENDIX .............................................................................................. 34 6.1 Specification ..................................................................................................................... 34 6.2 Default values ................................................................................................................... 36 6.3 Limitations with Water-Glycol Mixtures ............................................................................. 36 6.4 Positioning ........................................................................................................................ 36 6.5 Error and Warning Messages ........................................................................................... 38 6.5.1 Error Messages ......................................................................................................... 38 6.5.2 Example Error Messages........................................................................................... 38 6.5.3 Modbus Error Messages (if Modbus fitted) ................................................................ 39 6.5.4 Flow Errors ................................................................................................................ 39 6.5.5 Flow Warnings ........................................................................................................... 39 6.5.6 Data Entry Errors ....................................................................................................... 40 Page ii Issue 1.1b July 20 UFM2/UBT User Manual 1 INTRODUCTION 1.1 General Description This manual describes the installation and use of the UFM2 flow meter and UBT energy meter: • UFM2 is an ultrasonic clamp-on flow meter for measuring flow rate and total flow with a volume pulse output and optional Modbus or 4-20 mA flow proportional output. It can be used as a standalone meter or as part of an integral management system. • UBT is an ultrasonic clamp-on thermal, heat/energy meter. It uses ultrasound to measure flow rate and is also equipped with PT100 temperature sensors to measure flow and return temperatures. The energy meter displays energy rate and totalised energy with pulse output and communication options, so it can be used as a standalone meter or as an integral part of Automatic Monitoring & Targeting (aM&T) or a Building Energy Management System (BEMS). The electronics and sensor housings form an integral unit which attaches to the pipe using the supplied hose clips. Power to the unit is provided by an external 12-24 VDC / 24 VAC power supply (7 W / 7 VA minimum). The unit operates on steel, stainless steel, copper and plastic pipes with internal diameter in the range 0.8” (20 mm) to 6.5” (165 mm) depending on the product purchased. The models can also be supplied with Modbus digital communication options. Typical applications: UFM2 UBT Hot water metering and flow measurement Hot water metering and flow measurement Flow measurement for heat metering Flow measurement for Energy Metering Chilled water metering and flow measurement Chilled water metering and flow measurement Potable water metering and flow measurement Process water metering and flow measurement Ultra-pure water metering and flow measurement. NOTE: The UBT default configuration is: • Instrument Type: Heating • Installation Side: Return • Fluid: Water Return refers to the location of the flow measurement relative to flow circuit. Issue 1.1b July 20 Page 1 UFM2/UBT User Manual 1.2 How Does It Work? The UFM2 and UBT meters use a cross correlation transit time algorithm to provide accurate flow measurements. An ultrasonic beam of a given frequency is generated by applying a repetitive voltage pulse to the transducer crystals.…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dwyer Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Dwyer UFM2-14 adalah compact ultrasonic flow meter tipe clamp-on yang dirancang untuk pengukuran aliran non-invasif pada pipa. Alat ini kompatibel dengan material pipa seperti steel, stainless steel, copper, dan plastic, dengan rentang diameter dalam pipa 0,8" hingga 6,5" (20 mm hingga 165 mm). Dengan catu daya 12-24 VDC / 24 VAC dan konsumsi daya minimum 7 W / 7 VA, flow meter ini ideal untuk aplikasi pengukuran aliran di berbagai peralatan industri tanpa perlu memotong pipa.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi dari Dwyer UFM2-14 compact ultrasonic flow meter?

Dwyer UFM2-14 adalah flow meter ultrasonik tipe clamp-on yang digunakan untuk mengukur laju aliran cairan di dalam pipa secara non-invasif. Alat ini dipasang di luar pipa tanpa perlu memotong atau menghentikan aliran, sehingga sangat praktis untuk aplikasi peralatan industri seperti sistem HVAC, pengolahan air, dan proses manufaktur.

Apa spesifikasi teknis dari Dwyer UFM2-14?

Spesifikasi teknis Dwyer UFM2-14 meliputi catu daya 12-24 VDC / 24 VAC dengan konsumsi daya minimum 7 W / 7 VA. Alat ini kompatibel dengan pipa berdiameter dalam 0,8" hingga 6,5" (20 mm hingga 165 mm) yang terbuat dari steel, stainless steel, copper, atau plastic.

Di mana beli Dwyer UFM2-14 di Indonesia?

Anda dapat membeli Dwyer UFM2-14 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda dapat menerima flow meter ini dengan mudah untuk kebutuhan pengukuran aliran di peralatan industri Anda.

Bagaimana cara memasang Dwyer UFM2-14?

Pemasangan Dwyer UFM2-14 cukup mudah karena bersifat clamp-on. Pertama, bersihkan area kontak sensor pada pipa. Kemudian, pasang sensor di luar pipa dengan diameter dalam 0,8" hingga 6,5" (20 mm hingga 165 mm). Hubungkan catu daya 12-24 VDC / 24 VAC dan kabel sinyal sesuai panduan. Alat siap digunakan tanpa perlu memotong pipa.

Apa keunggulan Dwyer UFM2-14 dibanding flow meter konvensional?

Keunggulan utama Dwyer UFM2-14 adalah pemasangan non-invasif tanpa perlu memotong pipa, sehingga tidak mengganggu aliran proses. Alat ini kompatibel dengan berbagai material pipa seperti steel, stainless steel, copper, dan plastic, serta memiliki rentang diameter dalam pipa 0,8" hingga 6,5" (20 mm hingga 165 mm), menjadikannya solusi fleksibel untuk berbagai aplikasi peralatan industri.

Digunakan dalam

Aplikasi umum untuk Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Produk

3G Electric memasok Dwyer measurement. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Average flow probe PAFS-1008
Average flow probe AFG-2
Dwyer
Average flow probe AFG-2
Average flow probe AFG-1
Dwyer
Average flow probe AFG-1
Dwyer
Dwyer
Average flow probe PAFS-1010
Dwyer
Dwyer
Average flow probe PAFS-1007
Dwyer
Dwyer
Average flow probe PAFS-1005

Lainnya dari Dwyer

Lihat semua Dwyer suku cadang
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203