Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
ParkerOil Nozzles

Parker Pressure regulator 24-VK1-2.5 5 Bars (replacement 24-VK1-300)

Regulator tekanan Parker 24-VK1-2.5 5 Bars adalah komponen presisi yang dirancang untuk digunakan pada pembakar industri yang dilengkapi dengan atomizer aliran balik, atomizer udara tekan, atau atomizer uap…

SKU 3G-CBM-03987

Juga terdaftar sebagai: FLU 34002 · FLU-34002

Merek
Parker
Item
Pressure regulator 24-VK1-2.5 5 Bars
Kategori
Oil Nozzles
UNSPSC
23153143 — Spray nozzle
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Parker
application
oil burners with return flow/compressed air/steam atomisers
max pressure
40 bar
regulator type
24-VK1
pressure rating
5 bar
max fuel temperature
140°C

Konten Lembar Data

REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Documentation The following information sheets illustrate the description below: 24-T201-4G-E Sectional view of the regulator 24-VK1 with main dimensions 24-T201-D0-E Graph of relative output at constant pressure drop 24-T201-DB-E Graph of output at 90° opened 24-T301-4G-E Sectional view of the regulator 24-VK2 with main dimensions General The regulator 24-VK is designed for use in or on oil burners equipped either with return flow atomisers or with compressed air atomisers or steam atomisers. Turning the regulator shaft changes the aperture inside the regulator, consequently changing the fuel flow rate. Both flanges at the regulator shaft are marked with a "+", a scale in 15° steps and a "-". The pointer mounted on one side of the regulator shaft shows the actual position of this shaft. The regulator is suitable for pressures up to 40 bar and fuel temperatures up to 140°C. Mounting The connection block has two 6,5 mm holes and four threaded M5 bores for mounting purposes. These provisions also allow mounting a control motor or an optional heating plate. To prevent malfunction, be careful when removing the plastic plugs from the connection ports and make sure no material stays behind. In case of air atomisation or steam atomisation, the regulator is to be connected in the supply line between the pump and the atomiser. With a return flow atomiser, the regulator is to be connected in the return line from the atomiser. Connections The connections on the block of the regulator are marked as follows: I Fuel inlet to the regulator. O Fuel outlet from the regulator. When choosing fittings, make sure that the channels inside the connection block remain fully open. Even a partial blockage at one of the channels inside will inevitably lead to malfunctioning of the regulator. Never use any additional sealant on the thread. The remains getting inside the regulator could lead to failures. There are no objections against the use of flat gasket rings to seal the fittings. © Fluidics Instruments BV Page 1/2 REGULATOR 24-VK 24-T201-UG-E MANUAL 11-06-09 Function Turning the regulator shaft changes the flow through the regulator. The marking of "+" and "-" always refers to the throughput of the regulator and not to the output of the actual atomiser. The throughput of the regulator is at minimum with the pointer at "-". Turning the regulator shaft towards "+" increases the throughput of the regulator. Therefore, in case of air or steam atomisation, the output of an atomiser is at maximum if the pointer is at "+". On the other hand, for a return flow atomiser, the output of the atomiser will be at minimum if the pointer is at "+". The flanges have a scale with 15° division. This scale allows reproducible adjustment of the regulator during operation. The throughput of the regulator always is related to a certain pressure difference between the inlet and the outlet of the regulator. The pressure drop across the regulator and the maximum throughput depend on the actual atomiser and system particulars. In order to benefit from the maximum angle of travel, the choice of the size for the regulator should be made in such a way that its maximum throughput fits the actual atomiser and method of atomisation. Here also system particulars should be taken into account. If firing heavy fuel, we advise mounting a heating device to preheat the regulator for those applications where the fuel flow often stops during longer intervals. It is sufficient to apply an electrical heating plate to preheat the regulator connection block. Two 6,5 mm bores in the connection block allow mounting such a heating plate. This heater could work permanently, but it should at least be switched on in time before fuel is supposed to start flowing to achieve correct operation. Maintenance The regulator normally does not require any maintenance. Wear or damage highly depends on fuel quality. The only moving part is the regulator shaft. After a long period of operation, wear on the sleeve or on the regulator shaft can occur, resulting in an increase of leak flow at minimum throughput. After a while some wear may occur on the o-rings. Complete seal sets are available for replacement. In case of wear of the sleeve or of the regulator shaft, it is advised to return the regulator to the factory for repair. It is not recommended to perform this kind of repairs without proper tools and test equipment. The regulator shaft and the sleeve are being manufactured within close tolerances to avoid operation difficulties after such repairs. To exchange the o-rings in the flange, remove the pointer, held by 1 screw. Remove any damages and polish any sharp edges at both ends of the regulating shaft. Remove both flanges, each held by 2 screws, but leave the regulating shaft in its place. Carefully remove both o-rings from their grooves using a sharp needle without damaging the flanges in any way. Before re-assembly, make sure all parts involved are undamaged and perfectly clean. In case the regulator shaft has come out by accident, put it back in the correct position. Otherwise, the regulator will not function at all afterwards. Put the new o-rings in place. Near the o-rings, the regulator shaft should be absolutely free of damages. Re-assemble the regulator in reverse order. The position of the pointer on the regulator shaft has been pre-set at the factory. Both ends of the regulator shaft have a pit for fixing the pointer in the correct position. If the regulator shaft is mounted properly and the pointer is fixed again using this pit, the characteristic of the regulator will not change after replacement of o-rings. © Fluidics Instruments BV Page 2/2 Regulator 24—VK1 24-T201-4G-E 28-09-10 M5x12/17_ (8x) Pointer O-ring 7,66x1,78 06.5 (2x) O-ring 17,17x1,78 Connection block Sleeve Flange Regulatorshaft © Fluidics Instruments BV Page 1/1
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Parker Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Regulator tekanan Parker 24-VK1-2.5 5 Bars adalah komponen presisi yang dirancang untuk digunakan pada pembakar industri yang dilengkapi dengan atomizer aliran balik, atomizer udara tekan, atau atomizer uap. Regulator tipe 24-VK1 ini memiliki rating tekanan 5 bar dan mampu menangani tekanan maksimum hingga 40 bar serta suhu bahan bakar maksimum 140°C. Produk ini merupakan pengganti langsung untuk model 24-VK1-300 dan sangat cocok untuk aplikasi ketel uap dan peralatan pembakaran di sektor industri kelapa sawit, semen, dan F&B di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa regulator Parker 24-VK1-2.5 digunakan?

Regulator Parker 24-VK1-2.5 digunakan pada pembakar industri untuk mengatur laju aliran bahan bakar. Regulator ini bekerja dengan atomizer aliran balik, atomizer udara tekan, atau atomizer uap. Dengan memutar poros regulator, bukaan internal berubah sehingga aliran bahan bakar dapat disesuaikan.

Apa spesifikasi teknis regulator Parker 24-VK1-2.5?

Regulator Parker 24-VK1-2.5 memiliki rating tekanan 5 bar, tekanan maksimum 40 bar, dan suhu bahan bakar maksimum 140°C. Tipe regulator ini adalah 24-VK1 dan merupakan pengganti untuk model 24-VK1-300. Regulator ini dirancang untuk tekanan hingga 40 bar dan suhu bahan bakar hingga 140°C.

Bagaimana cara memasang regulator Parker 24-VK1-2.5?

Regulator dipasang pada blok koneksi yang memiliki dua lubang 6,5 mm dan empat ulir M5. Untuk atomisasi udara atau uap, regulator dihubungkan pada jalur suplai antara pompa dan atomizer. Untuk atomizer aliran balik, regulator dihubungkan pada jalur balik dari atomizer. Jangan gunakan sealant tambahan pada ulir.

Di mana beli regulator Parker 24-VK1-2.5 di Indonesia?

Anda dapat membeli regulator Parker 24-VK1-2.5 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Digunakan dalam

Aplikasi umum untuk Parker
Injection molding machine proportional directional control — Parker solenoid coils and proportional valve cartridges for mold-closing and hydraulic actuation circuits
Construction equipment hydraulic steering and boom control — Parker directional control valves with solenoid actuation for excavator and loader hydraulic systems
Industrial press forming systems — Parker pressure-relief and proportional directional valves for tonnage control and cycle sequencing
Material-handling conveyor systems — Parker proportional control valves with solenoid pilot stages for smooth load acceleration and deceleration
Tire-building machinery — Parker solenoid-actuated directional cartridges for synchronized multi-axis hydraulic positioning
Forestry and mobile equipment — Parker valve spools and solenoid assemblies rated for harsh-environment hydraulic circuits and mobile-duty pressure cycling

Parker Produk

3G Electric memasok Parker oil nozzles. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Pressure regulator 24-VK1-4.2 5 Bars (replacement 24-VK1-650)
CBM
CBM
Pressure regulator 24-VK1-5.2 5 Bars (replaces 24-VK1-850)
CBM
CBM
Pressure regulator 24-VK1-3.3 5 Bars (replaces 24-VK1-450)
CBM
CBM
Pressure regulator 24-VK1-2.7
This Parker pressure regulator is constructed with a stainless steel body and features 1/4 in FNPT x FNPT connections. It provides an adjustable outlet pressure range of 14.7 psi to 24.7 psi. Suitable for use in pneumatic systems requiring corrosion resistance and stable pressure control
Parker
This Parker pressure regulator is constructed with a stainless steel body and features 1/4 in FNPT x FNPT connections. It provides an adjustable outlet pressure range of 14.7 psi to 24.7 psi. Suitable for use in pneumatic systems requiring corrosion resistance and stable pressure control
This Parker stainless steel pressure regulator features 1/4 in FNPT x FNPT connections and a pressure range of 14.7 psi to 24.7 psi. It is used to reduce and stabilize inlet pressure in pneumatic systems, suitable for industrial applications requiring corrosion resistance
Parker
This Parker stainless steel pressure regulator features 1/4 in FNPT x FNPT connections and a pressure range of 14.7 psi to 24.7 psi. It is used to reduce and stabilize inlet pressure in pneumatic systems, suitable for industrial applications requiring corrosion resistance

Lainnya dari Parker

Lihat semua Parker suku cadang
Fluidics 0.85 45° SF
Parker
Fluidics 0.85 45° SF
Fluidics 0.45 80° HF
Parker
Fluidics 0.45 80° HF
Fluidics 1,10 60° SF
Parker
Fluidics 1,10 60° SF