Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
CBMOil, Fuel & Nozzles

CBM Pipa Bahan Bakar 24-HA-D-800-3/8

CBM Fuel pipe 24-HA-D-800-3/8 adalah nosel minyak (oil nozzle) tipe burner lance dengan spill-back disc atomiser dan shut-off needle pegas. Produk ini dirancang untuk pembakar industri berbahan bakar minyak, dengan…

SKU 3G-CBM-03996

Juga terdaftar sebagai: FLU 36006 · FLU-36006

Merek
CBM
Item
Pipa Bahan Bakar 24-HA-D-800-3/8
Kategori
Oil, Fuel & Nozzles
UNSPSC
23153143 — Spray nozzle
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

CBM
fuel
oil
type
burner lance with spill-back disc atomiser
shut off
shut-off needle with spring closure
connection
3/8 inch
o ring size
6.02x2.62

Konten Lembar Data

BURNERLANCE 24-HA-D 24-Y101-UG-E MANUAL 22-11-05 Documentation The following information sheets illustrate the description below: 24-Y101-4G-E Sectional view of the lance with main dimensions 24-W101-6G-E Sectional view of the head of the lance with atomiser discs 00-Y101-8G-E Diagram of pneumatic/hydraulic system inside the lance (1 solenoid) 00-Y101-8H-E Diagram of pneumatic/hydraulic system inside the lance (2 solenoids) General The burnerlance 24-HA-D is especially suitable for use in or on an oil burner and is designed to operate spill back disc atomisers with shut-off needle. The strong spring on the actuating rod pushes the needle in closed position. This ensures a reliable shut-off under all circumstances. Compressed air actuates the piston for opening, either controlled by two external solenoid valves (see 00-Y101-8H-E) or by one 3/2 solenoid valve (see 00-Y101-8G-E). The piston has a fixed travel, pulling the needle in the correct position when it opens. During the pre-purge period of the burner, the needle is keeping the orifice closed and the fuel circulates through the lance at pre-set supply and return pressure. On energising both solenoid valves or the 3/2 solenoid valve, even after long idle intervals, there is immediate atomisation guaranteeing perfect ignition. The burnerlance is suitable for supply pressures from 20 up to 40 bar and fuel temperatures up to 140°C. Mounting the atomiser discs Often a lance is delivered with the discs mounted. This is just to avoid loss of parts during transportation. The capnut then is screwed on by hand, not tightened. In this case, you should also mount the atomiser discs as described below. The orifice and the swirler are to be build in according to information sheet 24-W101-6G-E. To ensure adequate sealing, the sealing surfaces at the adaptor, at both sides of the swirler and at the orifice should not be damaged. Never use any additional sealant on these surfaces. Remove the capnut from the lance. Make sure all parts involved are clean and free from any dust or other particles. Slide the swirler over the needle. It should glide smoothly. Place the orifice and the swirler, in the right order and position, straight inside the capnut as shown in sheet 24-W101-6G-E. It is advised to apply a little "Molykote HSC" or equivalent compound, on the thread of the adaptor only, to prevent problems when dismounting the capnut after a longer period. The sealing surface of the adaptor, the inside of the lance, the needle and the atomiser discs are to be kept absolutely clean. Now carefully slide the capnut containing the discs over the needle and screw on the nut by hand as tight as possible. Tighten the capnut firmly with a spanner. The adaptor has flat sides to hold the lance while screwing or unscrewing the capnut. These flats exclusively serve this one purpose! © Fluidics Instruments BV Page 1/3 BURNERLANCE 24-HA-D 24-Y101-UG-E MANUAL 22-11-05 Connections The connections (see 00-Y101-8G-E and 00-Y101-8H-E) on the block of the lance are marked as follows: S Fuel supply to the atomiser. The pressure only depends on the desired behaviour for the atomiser. R Fuel return from the atomiser. Fuel output control is achieved by connecting either a pressure or a volume regulator. C Compressed air supply and return for needle actuation. A filter having meshes smaller than 50 µm should be present. The needle opens correctly at a pressure between 5 and 15 bar. The returning air should be allowed to flow freely without counterpressure. Only then reliable closing of the needle is possible. To prevent malfunction, be careful when removing the plastic plugs from the connection ports and make sure no material stays behind. When choosing fittings, make sure that the channels inside the connection block remain fully open. Even a partial blockage at one of the channels inside will inevitably lead to malfunctioning of the burnerlance. Never use any additional sealant on the thread. The remains getting inside the lance could lead to failures. There are no objections against the use of flat gasket rings to seal the fittings. Function During the pre-purge period, both the external solenoid valve in the supply line and the external volume or pressure regulator are open. The solenoid valves operating the needle are currentless. Thus, the spring loaded actuating rod pushes the needle against the seat of the orifice up front, keeping it closed, preventing fuel from reaching the furnace prematurely. The pressure at port "C" is 0 bar. The fuel circulates from port "S" via the swirler in the atomiser through the lance toward port "R", bringing the whole up to operating temperature. Before opening the needle, make sure the IGNITION IS TURNED ON. In addition, the external regulator and the combustion airflow are to be adjusted beforehand in such a way that the burner will START ON LOW FLAME. As soon as one switches on the solenoid valves operating the needle, the pressure at port "C" increases to 5 bar or more; the rod retracts the needle and the ignition causes a flame immediately. An external volume or pressure regulator in the return line controls the output flow of the atomiser. Interruption of the power supply to the solenoid valve at port "C" leads to immediate closing of the needle, handled by the spring. The fuel flow from the atomiser stops abruptly. The pressure at port "C" drops to 0 bar. The fuel circulation from port "S" via the swirler toward port "R" continues as before, maintaining the temperature of the lance. If firing heavy fuel, we advise mounting a heating device to preheat the lance for those applications where the fuel supply to port "S" often stops during longer intervals. Normally it is sufficient to apply an electrical heating plate just to preheat the connection block at the lance. Four threaded bores in the connection block allow mounting such a heating plate. This heater could work permanently, but it should at least be switched on in time before fuel is supplied to port "S" to achieve correct operation of the control system inside the lance. © Fluidics Instruments BV Page 2/3 BURNERLANCE 24-HA-D 24-Y101-UG-E MANUAL 22-11-05 Maintenance The burnerlance normally does not require any maintenance. Wear or damage of the orifice, the swirler and the needle highly depend on fuel quality. These parts are easy to exchange. The only moving part is the actuating rod with the piston. After a while some wear may occur on the o-rings. Complete seal sets are available for replacement. Before taking one of the following steps, remove the orifice and the swirler from the lance and put the capnut back on as protection for the needle and the adaptor. Always pay attention not to damage the sealing surfaces at the adaptor and the atomiser discs. Before re-assembly, make sure all parts involved are undamaged and perfectly clean. To exchange the o-ring 25,12x1,78 on the piston, remove the cover, held by 4 screws. Pull out the bearing together with the o-ring 33,00x2,62. Exchange the o-ring 25,12x1,78 and put the bearing with o-ring back in place. Now we can mount the cover. To exchange the inner o-rings 6,02x2,62, remove the cover, held by 4 screws. Pull out the bearing together with the o-ring 33,00x2,62. Use a piece of wood or plastic to push back the needle head. WARNING FOR INJURY: The actuating rod comes out suddenly. After that, you can pull it out easily. Do not damage the head of the needle. The actuating rod has to be taken apart to exchange the o-rings 6,02x2,62. Remove the pin that connects the holder to the rod and take the holder off. The rod in lances longer than 800 mm is – for extra guidance – provided with triangles. Each triangle is secured with a pin. Remove these pins and triangles. Clamp the free end of the rod in a bench vice with soft yaws placing the stop against the yaws. Remove the pin holding the stop and release the spring pressure by slowly opening the vice. Take off the stop, the spring, the spring disc, the disc and the between disc. Polish any sharp edges on the rod and exchange the o-rings 6,02x2,62. Near the o-rings, the rod should be absolutely free of damages. Re-assemble the actuating rod in reverse order. To exchange the needle, just remove the pin that holds it. Secure the new needle with the same pin. To test, put the actuating rod into the burnerlance without the o-ring 25,12x1,78 and without the o-rings 18,72x2,62 on the discs. The rod should move freely. Pull it back a little, mount both o-rings 18,72x2,62 on the discs and push the rod in place. Slide the bearing over the piston in the connection block and turn it to check the fit. If fitting correctly, mount the o-ring 25,12x1,78 on the piston and push the bearing with the o-ring 33,00x2,62 back in place. Now we can mount the cover. Finally, mount the orifice and the swirler as described under "Mounting the atomiser discs". © Fluidics Instruments BV Page 3/3 Burnerlance 24-HA-D-"L"-"d" welded 24-Y101-4G-E 23-03-22 "d" (1:4) Capnut w.st.nr.: 1.0715 Needle w.st.nr.: 1.2210 Adaptor w.st.nr.: 1.4122 SW. 32 Holder w.st.nr.: 1.2210 7.5 45 M5x12/15 Triangle w.st.nr.: 1.0715 only for lances 45 from 800mm "L" Rod 7.5 w.st.nr.: 1.2210 Stop w.st.nr.: 1.2210 Spring w.st.nr.: 1.4568 60 Ø40 60 30 16 16 G3/8" "R" G3/8" "S" G1/4" "MR" Connection block w.st.nr.: 1.0122 19 Spring disc w.st.nr.: 1.0715 Disc w.st.nr.: 2.0401 60 O-Ring 6.02x2.62 viton Between disc w.st.nr.: 2.0401 G1/4" "MO" O-Ring 18.72x2.62 viton…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CBM Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

CBM Fuel pipe 24-HA-D-800-3/8 adalah nosel minyak (oil nozzle) tipe burner lance dengan spill-back disc atomiser dan shut-off needle pegas. Produk ini dirancang untuk pembakar industri berbahan bakar minyak, dengan koneksi 3/8 inch dan o-ring ukuran 6,02x2,62. Burner lance ini cocok untuk tekanan suplai 20 hingga 40 bar dan suhu bahan bakar hingga 140°C, memastikan atomisasi sempurna bahkan setelah jeda operasi yang lama.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi dari CBM Fuel pipe 24-HA-D-800-3/8?

CBM Fuel pipe 24-HA-D-800-3/8 berfungsi sebagai burner lance dengan spill-back disc atomiser dan shut-off needle pegas untuk pembakar industri berbahan bakar minyak. Nosel ini memastikan penutupan yang andal dan atomisasi segera saat katup solenoida diaktifkan, cocok untuk tekanan suplai 20 hingga 40 bar dan suhu bahan bakar hingga 140°C.

Apa spesifikasi teknis dari CBM Fuel pipe 24-HA-D-800-3/8?

Spesifikasi teknis CBM Fuel pipe 24-HA-D-800-3/8 meliputi: tipe burner lance dengan spill-back disc atomiser, shut-off needle dengan penutup pegas, koneksi 3/8 inch, dan o-ring ukuran 6,02x2,62. Produk ini dirancang untuk tekanan suplai 20 hingga 40 bar dan suhu bahan bakar hingga 140°C.

Di mana beli CBM Fuel pipe 24-HA-D-800-3/8 di Indonesia?

Anda dapat membeli CBM Fuel pipe 24-HA-D-800-3/8 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Bagaimana cara memasang atomiser disc pada CBM Fuel pipe 24-HA-D-800-3/8?

Pemasangan atomiser disc pada CBM Fuel pipe 24-HA-D-800-3/8 harus mengikuti lembar informasi 24-W101-6G-E. Pastikan permukaan sealing pada adaptor, kedua sisi swirler, dan orifice tidak rusak. Jangan gunakan sealant tambahan. Kencangkan capnut dengan tangan, jangan terlalu kencang.

Digunakan dalam

Aplikasi umum untuk CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Produk

3G Electric memasok CBM oil, fuel & nozzles. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Fuel rod 24-HA-D-700-2/8
CBM
CBM
Oil line 24-HA-D-650-3/8
CBM
CBM
Oil rod 24-HA-D-600-2/8
CBM
CBM
Oil tube 24-HA-D-650-2/8
CBM
CBM
Oil rod 24-HA-D-550-2/8
CBM
CBM
Oil rod 12-HA-D-555

Lainnya dari CBM

Lihat semua CBM suku cadang
CBM
CBM
Fuel oil pipe 24-HA-D-700-3/8
CBM
CBM
Disc type 24-E-1.80
CBM
CBM
Oil pipe 24-HA-D-800-2/8
CBM
CBM
Pressure regulator 24-VK1-2.7
CBM
CBM
Pellet type 24-D-2,00
CBM
CBM
Atomizer type 24-P-13
CBM
CBM
Pellet type 24-D-1.80
CBM
CBM
Disc type 24-D-2.50