Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
SatronicBurner Controls

Satronic CM391.2 10.10 relay

Satronic CM391.2 10.10 adalah relay kontrol pembakar (burner control relay) dari seri Eurobox yang dirancang khusus untuk sistem kontrol pembakar gas otomatis. Produk ini memiliki fitur pengaman non-volatile…

SKU 3G-CBM-05992

Juga terdaftar sebagai: REL 45108 · REL-45108

Merek
Satronic
Item
CM391.2 10.10 relay
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Satronic
type
CM391.2
isolation
reinforced
application
automatic gas burner control
safety function
non-volatile lock-out

Konten Lembar Data

EUROBOX SERIES TYPES CM... SM... MM... Application AUTOMATIC GAS BURNER CONTROL This range of electronic gas burner contrai systems has SYSTEMS FOR GAS BURNERS AND GAS been designed specifically for atmospheric and fan assisted BURNING APPLIANCES WITH OR burners for intermittent operation (systems for non­ WITHOUT FAN permanent operation ). Ali these contrais are provided with non-volatile lock-out, which means that a restart from the safety shut-down condition can only be accomplished by a manual reset of the system. The automatic burner contrai units of this series are suitable for: -combi boilers -heating boilers -warm air generators -radiant heaters -water heaters Due to the design and the variety of models they can be used also for the automation of ovens, cookers and in general in gas firing installations with atmospheric burner. Features Table 1 shows the main features of this series. Other important features are: - EC - Type certification (CE Reg. N° 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; - in accordance with EN298 (European standard for automatic gas burner contrai systems); - flame monitoring by the rectification property of the flame: ionization; - two independent safety contacts in series on the gas valve output; - electrical service lite at max. loading >250.000 operations; - inbuilt or remote reset facility; - inbuilt ignition device completely of solid state design and high efficiency; - auxiliary contact for low power ignition or main gas valve contrai for intermittent pilot systems (this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SEL V circuits - Safety Extra Low Voltage, e.g. 24V); - different connections and fixings. TABLE 7 BORNER RESET CONNECTION c O N C 7 O ao L L V N O V ~ Û w d U U ~ ~ 'Ç ~ O O — E a L a L a ~ ~ m d ~ ô ~ O v c :~ a ~ z ~ î ~ d O O ~ ~ ~ O ~ ~n O Ÿ Ÿ Ÿ Ÿ ~ ~ ~ ~ ~ ~ X ~ ~ p û U U U U ~O LI O Q N d = U O N N tin (fin CM 197 (B) (A) AMCLXN SM 191 (A) AMCLXN SM 192 (B) (A) AMCLXN CM 381 (B) (A) FMCLXN CM 391 (A) FMCLXN SM 152 (B) (A) AMCLXN SM 592 (B) (A) AMCLXN MM 797 (B) (A) AMCLXN MM 192 ~ (B) (A) AMCLXN NOTE: (A) Box type xxxxx.1 - xxxxx.2 (1):This contact is not isolated from the main supply voltage by reinforced (B) Box type xxxxx.3 - xxxxx.4 isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g. 24V. (2) : Flame failure during TS causes spark restoration. TECHNICAL DATA -Minimum ionization current: 1.2E~A Supply Voltage: 230V-50/60Hz on request: 0.5µA on request: 110/120V-50/60Hz -Recommended ionization current: 3 = 5 times the Operating temperature range: -20°C +60°C minimum ionization current Amblent humidity: 95% max at 40°C -Max. length of the Gable: 1m Protection degree: -Minimum insulation resistance of Gable and flame detector socket NG: IP 40 (alter installation) device to Barth: z 50M52 socket P/R IP 00 -Max. parasitic capacitance of Times: detection probe: s 1 nF -Prepurge or waiting time (TW): 1,5/3/5/10/20/30/40 s -Max. short circuit current: < 200E~A AC -Safety time (TS): 3/5/8/10/20/30/40/50/60 s Ignition: -Drop out time on running flame failure: <1s -Ignition voltage: 8 KV at 30pF loading The times given on the burner control label correspond to -Repetition rate: 25 Hz the values guaranteed. The actual values differ slightly from -Max.length of the Gable: 2m the values given, pre-purge and waiting times are in fact -Spark gap recommended: 2-4 mm longer and safety time shorter than their nominal values. -Consumption: 2,5 VA Power cônsumption, at starting up: -Spark energy: 15 mJ atmospheric burner 10 VA Weight: atmospheric fan-assisted burner 12 VA -with socket P or R: 220 g Power consumption, running: -with socket NG or MG: 275 g atmospheric burner 7 VA Controls for special applications: atmospheric fan-assisted burner 9 VA On request it is possible to meet special requirements Contact rating: I max concerning times, repetition rate of the sparks, minimum -Thermostat: 4 A cos cp = 0.4 ionization current and operating cycle. -EV1: 0.5A coscp =0.4 CONSTRUCTION -EV2: 0.5 A cos cp = 0.4 The enclosure made of plastic material protects the control -EVG: 0.5 A cos cp = 0.4 from mechanical damage, dust and dirt from the conditions -Fan: 1 A cos cp = 0.4 of installation.The particular construction, consisting of four -Alarm: 0.5 A cos cp = 1 printed circuit boards in order to forma "box" structure, has -Auxiliary contact: 0.5 A cos cp = 0.4 allowed a reduction in the volume of the control unit. -Externat ignition: 1.5 A cos cp = 02 A varistor protects the control from voltage transients on the Max. length of the Gables of mains supply. An internat fuse protects the relays of the externat components: 1 m control box in case of short circuits on the outputs (valves, Fuse rating internat: 4 A Fast fan and lock-out signal). This is not an accessible fuse and Fuse rating externat: 3.15 A Fast the control must be protected with a fuse of the fast blow Flame control: type suitable to the Joad connected and never exceeding The ionization flame detector device makes use of the 3.15A. rectification property of the flame. Overall Dimensions The ionization flame detector device is not a safe to touch The control units of the EUROBOX series Gan be supplied output (no provision, with protective impedances). with different executions of the enclosure depending on the functions and the fixing system required. Enclosures are available with or without reset button and screw terminal suitable for the CM381 control unit. Socket can be provided or not with fixing brackets on the sides. type P differentiates from type R on positions 8…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Satronic Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Satronic CM391.2 10.10 adalah relay kontrol pembakar (burner control relay) dari seri Eurobox yang dirancang khusus untuk sistem kontrol pembakar gas otomatis. Produk ini memiliki fitur pengaman non-volatile lock-out, yang berarti setelah terjadi penghentian darurat (safety shut-down), sistem hanya dapat direset secara manual. Relay ini dilengkapi dengan isolasi diperkuat (reinforced isolation) dan dua kontak pengaman independen yang terpasang seri pada output katup gas, memastikan keandalan tinggi pada aplikasi ketel uap, pemanas udara, dan pemanas air.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi utama Satronic CM391.2 10.10 relay?

Satronic CM391.2 10.10 adalah relay kontrol pembakar gas otomatis yang memonitor nyala api menggunakan prinsip ionisasi (rectification property of the flame). Fungsinya adalah mengontrol urutan penyalaan dan pengamanan pada pembakar gas atmosferik atau dengan kipas, serta memberikan penguncian non-volatile lock-out jika terjadi kegagalan.

Apa spesifikasi teknis Satronic CM391.2 10.10?

Spesifikasi utama Satronic CM391.2 10.10 meliputi: tipe CM391.2, isolasi diperkuat (reinforced isolation), aplikasi untuk kontrol pembakar gas otomatis, fungsi pengaman non-volatile lock-out, dua kontak pengaman independen pada output katup gas, dan masa pakai listrik >250.000 operasi pada beban maksimal.

Di mana beli Satronic CM391.2 10.10 relay di Indonesia?

Anda dapat membeli Satronic CM391.2 10.10 relay melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda tidak perlu repot mengurus impor sendiri. Hubungi kami untuk minta penawaran.

Apakah Satronic CM391.2 10.10 cocok untuk aplikasi ketel uap?

Ya, Satronic CM391.2 10.10 dirancang untuk berbagai aplikasi pembakaran gas, termasuk ketel uap (heating boilers), pemanas udara (warm air generators), pemanas air (water heaters), dan oven. Produk ini memiliki sertifikasi EC Type (CE Reg. No. 63AQ0625) sesuai dengan Gas Appliance Directives 90/396 dan 93/68.

Bagaimana cara mereset Satronic CM391.2 10.10 setelah lock-out?

Karena fitur non-volatile lock-out, Satronic CM391.2 10.10 hanya dapat direset secara manual setelah terjadi penghentian darurat. Tombol reset dapat diakses langsung pada unit atau melalui koneksi remote reset yang tersedia. Pastikan penyebab lock-out diperbaiki sebelum melakukan reset.

Digunakan dalam

Aplikasi umum untuk Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Produk

3G Electric memasok Satronic burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
CM391 TW1.5/TS10 relay
Satronic
Satronic
SM 11F relay
Satronic
Satronic
Relay CM 12U
Satronic
Satronic
Relay CM 32 TW20/TS10
Satronic
Satronic
Relay SM 592.2 TW5/TS10

Lainnya dari Satronic

Lihat semua Satronic suku cadang
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)