Satronic RE3 relai ionisasi

Satronic RE3 adalah relay ionisasi yang berfungsi sebagai pendeteksi nyala api untuk pembakar gas, sesuai standar EN 60730. Relay ini dapat menggunakan tabung UV atau elektroda untuk memanfaatkan efek penyearah nyala…

SKU 3G-CBM-06012

Juga terdaftar sebagai: REL 45132 · REL-45132

Merek
Satronic
Item
RE3 relai ionisasi
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Satronic
type
flame detector for gas burners
model
RE3
standard
EN 60730
cable length
600 mm
external fuse
50 mA T
reaction time
<1 s
contact rating
5A 250V AC (cosφ=1.0), 3A 250V AC (cosφ=0.4), 5A 30V DC
power consumption
3 VA
minimum ionization current
0.5 µA
recommended ionization current uv
>15 µA
recommended ionization current electrode
>5 µA

Konten Lembar Data

FLAME DETECTOR FOR GAS TYPE RE3 DESCRIPTION The RE3 control is suitable to verify the presence of flame on gas burners. In fact it can use either a UV phototube or an electrode to exploit the flame rectification effect (ionization). FEATURES − in accordance with EN 60730; − electrical service life at max. declared loading > 250.000 operations; − compact and easy installation; − connecting socket with screws or fast-on terminals (types A, B, N and T); − signalization with LEDs of different colour: green (POWER) and red (FLAME). MAIN APPLICATIONS The RE3 flame detector is mainly used for industrial applications and for the installation of semiautomatic ignition and control systems, when it is necessary to control simultaneously and sequentially several burners. The presence of LEDs to signalise the operation also permits the use of RE3 control simply as flame detector. OPERATION Supply is signalled by the turning on of the green coloured LED (POWER) fitted on the front of the plastic enclosure. A second LED, red coloured, placed next to the first one, turns on when the flame detection has occurred. This event corresponds to the switching on of the independent contacts available in output. 4071_r06 1/4 OVERALL DIMENSIONS Fig.2 Fig.3 Socket A B (code 18210130) Socket T As regards the phototube life, we suggest to replace it after 10.000 hours to avoid the danger of a “flame on” signal also after the flame has been extinguished, which is likely to happen when the tube gets too old. DETECTION ELECTRODE The detection electrode we produce can be supplied in different shapes and dimensions (see Fig.4). Socket N (18210095) Fig.1 This control can use the connecting sockets with screw terminals mod. A B, N or socket mod. T. for fast - on Fig.4 terminals, which couples with lateral bolted enclosure. TECHNICAL DATA ACCESSORIES - Supply: 220-230V-50/60Hz The users’ different requirements regarding flame detection on request: 240V-50/60Hz for gas systems, can be met by using the following probes 110-120V-50/60Hz of our production: - Operating temperature: 0 ÷ 60°C - Humidity: 95% max. at 40°C - UV1 standard phototube (Fig.2); - Case Protection Degree: IP40 - UV1/H high sensitivity phototube: - Power consumption in running: 3 VA Case: nylon - Contact rating: 5A 250 V AC ( cosϕ = 1.0) Case diameter: mm 22 3A 250 V AC ( cosϕ = 0.4) Case length: mm 85 5A 30 V DC Cable length: mm 600 (standard) - External Fuse (F): 50 mA T - UV2/N (Fig.3): - Minimum ionization current: 0,5µA Case: nylon - Recommended ionization current: Case diameter: mm 17 with UV tube: > 15µA Case length: mm 76 with electrode: > 5µA Cable length: mm 600 (standard) - Reaction time: < 1s Weight: with AB socket 280 g with B socket 300 g with T socket 250 g with N socket 290 g 2/4 4071_r06 CONSTRUCTION The plastic material made enclosure protects the control from possible damages depending on crashes, openings, dust deposit, contact with outside ambient. Two LEDs of different colour, GREEN for power on and RED for flame on, fitted on the upper side of the enclosure, permit an immediate identification of the state of burner and control; a version without signalling LEDs is also available. DIRECTIONS FOR INSTALLATION DETECTION − Connect and disconnect the control only with supply off. PROBE − The control can be assembled in every position. − Avoid exposure to dripping water. − Ventilation with the lowest temperature ensures the longest life of the control. − Make sure that you are using the correct type and code before installing or replacing the control. ELECTRICAL INSTALLATION Fig.6 − Every contact must be protected with a fuse of the fast Fig.7 shows the diagram suitable to the installation of a blow type suitable to the loads connected; semiautomatic system for gas burners. For the flame − Before starting the control, check cables and detection, both an ionization electrode or a phototube can connections carefully (see Fig.5). Wrong be used. connections can damage the control and Acting on the manual start button PM (with two contacts compromise the safety of the application; normally open) supply is given to the TR ignition − Avoid placing the detection cable close to power or transformer and the EV 1 gas valve; the manual pressure ignition cables; on the button must be kept until the flame is built and − Use a detection cable as short as possible (max. stable. recommended length <5m); − A suitable degree of protection must be guaranteed; APPLICATION EXAMPLES − The relevant electrical safety standards must be respected. NOTE1 NC COM NA NA COM NC BLUE 5A 5A UV BRAHMA TYPE RE3 MADE IN ITALY NOTE1: WIRE MARKED WITH NUMBER 8 Fig.7 DET. PROBE NC COM NA NA COM NC By releasing the button PM, the ignition transformer is turned off and the operation continues until one of the following situations occurs: - action on the manual stop button PA; - intervention of the thermostat T; - flame failure. In any situation, the operation can be reset only by manual 5A 5A intervention on start button PM. In the same picture is also represented a duty example of the second available contact, to detect the flame in BRAHMA TYPE RE3 MADE IN ITALY distance. Fig.8 represents two connection diagrams for using the Fig.5 RE3 flame detector with the control box for automatic gas CHECKING AT START burners, model CM391 belonging to the EUROBOX series Always check the control before the first start and also after (see the relevant leaflet). a long period of system off. Before any ignition attempt make sure that the combustion chamber is free from gas. Then check that the level of the flame signal is sufficient (see Fig.6a and 6b for the measuring). 4071_r06 3/4 BURNER 1 BURNER 2 LIVE NEUTRAL (a) LIVE NEUTRAL (b) Fig.8 The diagram in Fig.8a differs from the one in Fig.8b for the presence of fan control and air pressure switch. This connection permits the ignition of two burners in sequence, with cross checking of the “flame on” state. A contact of the internal relay of RE3 is used to check the efficiency of the detector to prevent the beginning of the ignition cycle if the NOTES ABOUT PRODUCT DISPOSAL The device detector doesn’t operate correctly. contains electronic components and cannot therefore be The ignition of burner 2 occurs only after the ignition of disposed of as normal household waste. For the disposal burner 1 and, as the flame detection is cross - checked procedure, please…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Satronic Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Satronic RE3 adalah relay ionisasi yang berfungsi sebagai pendeteksi nyala api untuk pembakar gas, sesuai standar EN 60730. Relay ini dapat menggunakan tabung UV atau elektroda untuk memanfaatkan efek penyearah nyala api (ionisasi). Dengan waktu reaksi <1 detik, konsumsi daya 3 VA, dan rating kontak 5A 250V AC (cosφ=1.0), 3A 250V AC (cosφ=0.4), 5A 30V DC, RE3 ideal untuk aplikasi industri dan sistem kontrol penyalaan semi-otomatis. Dilengkapi LED hijau (POWER) dan merah (FLAME) untuk indikasi operasional.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Satronic RE3 digunakan?

Satronic RE3 adalah relay ionisasi yang digunakan sebagai pendeteksi nyala api pada pembakar gas. Alat ini memverifikasi keberadaan api menggunakan tabung UV atau elektroda ionisasi, cocok untuk aplikasi industri dan sistem kontrol penyalaan semi-otomatis.

Apa spesifikasi teknis Satronic RE3?

Spesifikasi Satronic RE3 meliputi: suplai 220-230V 50/60Hz (240V 50/60Hz opsional), konsumsi daya 3 VA, waktu reaksi <1 detik, arus ionisasi minimum 0,5 µA, rating kontak 5A 250V AC (cosφ=1.0), 3A 250V AC (cosφ=0.4), 5A 30V DC, dan panjang kabel 600 mm. Sesuai standar EN 60730.

Bagaimana cara memasang Satronic RE3?

Pemasangan Satronic RE3 mudah dengan soket koneksi yang tersedia: tipe A, B, N (sekrup) atau tipe T (fast-on terminal). Pastikan sekring eksternal 50 mA T terpasang. Hubungkan elektroda deteksi atau tabung UV sesuai panduan, dan perhatikan indikasi LED untuk power dan flame.

Di mana beli Satronic RE3 di Indonesia?

Anda dapat membeli Satronic RE3 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Apa perbedaan antara RE3 dan model lain dari Satronic?

Satronic RE3 dirancang khusus untuk pembakar gas dengan deteksi ionisasi atau UV, sesuai EN 60730. Model lain mungkin memiliki spesifikasi berbeda seperti tegangan suplai atau waktu reaksi. RE3 menawarkan waktu reaksi <1 detik dan konsumsi daya 3 VA, ideal untuk aplikasi industri.

Digunakan dalam

Aplikasi umum untuk Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Produk

3G Electric memasok Satronic burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
SM 11F relay
Satronic
Satronic
Relay SR3/TR2V SF
Satronic
Satronic
Relay SM 152.2
Satronic
Satronic
Relay SM 191.2
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
Relay CM 12U

Lainnya dari Satronic

Lihat semua Satronic suku cadang
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)