Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Relai Brahma MM 192.4 TW5/TS10 - Burner Controls
BrahmaBurner Controls

Relai Brahma MM 192.4 TW5/TS10

Brahma Relay MM 192.4 TW5/TS10 adalah unit kontrol pembakar otomatis dari seri EUROBOX yang dirancang khusus untuk pembakar gas atmosferik dan kipas bantu dengan mode operasi intermiten. Produk ini dilengkapi dengan…

SKU 3G-CBM-06015

Juga terdaftar sebagai: REL 45136 · REL-45136

Merek
Brahma
Item
Relai Brahma MM 192.4 TW5/TS10
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Brahma
type
MM 192.4
series
EUROBOX
application
automatic gas burner control
operation mode
intermittent

Konten Lembar Data

EUROBOX SERIES TYPES CM... SM... MM... Application AUTOMATIC GAS BURNER CONTROL This range of electronic gas burner contrai systems has SYSTEMS FOR GAS BURNERS AND GAS been designed specifically for atmospheric and fan assisted BURNING APPLIANCES WITH OR burners for intermittent operation (systems for non­ WITHOUT FAN permanent operation ). Ali these contrais are provided with non-volatile lock-out, which means that a restart from the safety shut-down condition can only be accomplished by a manual reset of the system. The automatic burner contrai units of this series are suitable for: -combi boilers -heating boilers -warm air generators -radiant heaters -water heaters Due to the design and the variety of models they can be used also for the automation of ovens, cookers and in general in gas firing installations with atmospheric burner. Features Table 1 shows the main features of this series. Other important features are: - EC - Type certification (CE Reg. N° 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; - in accordance with EN298 (European standard for automatic gas burner contrai systems); - flame monitoring by the rectification property of the flame: ionization; - two independent safety contacts in series on the gas valve output; - electrical service lite at max. loading >250.000 operations; - inbuilt or remote reset facility; - inbuilt ignition device completely of solid state design and high efficiency; - auxiliary contact for low power ignition or main gas valve contrai for intermittent pilot systems (this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SEL V circuits - Safety Extra Low Voltage, e.g. 24V); - different connections and fixings. TABLE 7 BORNER RESET CONNECTION c O N C 7 O ao L L V N O V ~ Û w d U U ~ ~ 'Ç ~ O O — E a L a L a ~ ~ m d ~ ô ~ O v c :~ a ~ z ~ î ~ d O O ~ ~ ~ O ~ ~n O Ÿ Ÿ Ÿ Ÿ ~ ~ ~ ~ ~ ~ X ~ ~ p û U U U U ~O LI O Q N d = U O N N tin (fin CM 197 (B) (A) AMCLXN SM 191 (A) AMCLXN SM 192 (B) (A) AMCLXN CM 381 (B) (A) FMCLXN CM 391 (A) FMCLXN SM 152 (B) (A) AMCLXN SM 592 (B) (A) AMCLXN MM 797 (B) (A) AMCLXN MM 192 ~ (B) (A) AMCLXN NOTE: (A) Box type xxxxx.1 - xxxxx.2 (1):This contact is not isolated from the main supply voltage by reinforced (B) Box type xxxxx.3 - xxxxx.4 isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g. 24V. (2) : Flame failure during TS causes spark restoration. TECHNICAL DATA -Minimum ionization current: 1.2E~A Supply Voltage: 230V-50/60Hz on request: 0.5µA on request: 110/120V-50/60Hz -Recommended ionization current: 3 = 5 times the Operating temperature range: -20°C +60°C minimum ionization current Amblent humidity: 95% max at 40°C -Max. length of the Gable: 1m Protection degree: -Minimum insulation resistance of Gable and flame detector socket NG: IP 40 (alter installation) device to Barth: z 50M52 socket P/R IP 00 -Max. parasitic capacitance of Times: detection probe: s 1 nF -Prepurge or waiting time (TW): 1,5/3/5/10/20/30/40 s -Max. short circuit current: < 200E~A AC -Safety time (TS): 3/5/8/10/20/30/40/50/60 s Ignition: -Drop out time on running flame failure: <1s -Ignition voltage: 8 KV at 30pF loading The times given on the burner control label correspond to -Repetition rate: 25 Hz the values guaranteed. The actual values differ slightly from -Max.length of the Gable: 2m the values given, pre-purge and waiting times are in fact -Spark gap recommended: 2-4 mm longer and safety time shorter than their nominal values. -Consumption: 2,5 VA Power cônsumption, at starting up: -Spark energy: 15 mJ atmospheric burner 10 VA Weight: atmospheric fan-assisted burner 12 VA -with socket P or R: 220 g Power consumption, running: -with socket NG or MG: 275 g atmospheric burner 7 VA Controls for special applications: atmospheric fan-assisted burner 9 VA On request it is possible to meet special requirements Contact rating: I max concerning times, repetition rate of the sparks, minimum -Thermostat: 4 A cos cp = 0.4 ionization current and operating cycle. -EV1: 0.5A coscp =0.4 CONSTRUCTION -EV2: 0.5 A cos cp = 0.4 The enclosure made of plastic material protects the control -EVG: 0.5 A cos cp = 0.4 from mechanical damage, dust and dirt from the conditions -Fan: 1 A cos cp = 0.4 of installation.The particular construction, consisting of four -Alarm: 0.5 A cos cp = 1 printed circuit boards in order to forma "box" structure, has -Auxiliary contact: 0.5 A cos cp = 0.4 allowed a reduction in the volume of the control unit. -Externat ignition: 1.5 A cos cp = 02 A varistor protects the control from voltage transients on the Max. length of the Gables of mains supply. An internat fuse protects the relays of the externat components: 1 m control box in case of short circuits on the outputs (valves, Fuse rating internat: 4 A Fast fan and lock-out signal). This is not an accessible fuse and Fuse rating externat: 3.15 A Fast the control must be protected with a fuse of the fast blow Flame control: type suitable to the Joad connected and never exceeding The ionization flame detector device makes use of the 3.15A. rectification property of the flame. Overall Dimensions The ionization flame detector device is not a safe to touch The control units of the EUROBOX series Gan be supplied output (no provision, with protective impedances). with different executions of the enclosure depending on the functions and the fixing system required. Enclosures are available with or without reset button and screw terminal suitable for the CM381 control unit. Socket can be provided or not with fixing brackets on the sides. type P differentiates from type R on positions 8…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Brahma Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Brahma Relay MM 192.4 TW5/TS10 adalah unit kontrol pembakar otomatis dari seri EUROBOX yang dirancang khusus untuk pembakar gas atmosferik dan kipas bantu dengan mode operasi intermiten. Produk ini dilengkapi dengan penguncian non-volatile yang memerlukan reset manual setelah kondisi mati aman, serta pemantauan nyala api menggunakan prinsip ionisasi. Relay ini cocok untuk aplikasi seperti ketel uap, pemanas air, dan generator udara panas, dan tersedia sebagai suku cadang pembakar industri di Indonesia melalui 3G Electric.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Brahma Relay MM 192.4 TW5/TS10 digunakan?

Brahma Relay MM 192.4 TW5/TS10 digunakan sebagai kontrol pembakar gas otomatis untuk sistem pembakar gas atmosferik dan kipas bantu dengan operasi intermiten. Produk ini cocok untuk ketel uap, pemanas air, generator udara panas, dan pemanas radian. Dilengkapi dengan penguncian non-volatile yang memerlukan reset manual setelah kondisi mati aman.

Apa spesifikasi Brahma Relay MM 192.4 TW5/TS10?

Brahma Relay MM 192.4 TW5/TS10 memiliki tipe MM 192.4 dari seri EUROBOX, aplikasi kontrol pembakar gas otomatis, dan mode operasi intermiten. Produk ini sesuai dengan standar EN298 dan memiliki sertifikasi EC-Type (CE Reg. N° 63AQ0625). Dilengkapi dengan dua kontak pengaman independen pada output katup gas dan perangkat pengapian solid state.

Bagaimana cara memilih Brahma Relay MM 192.4 TW5/TS10 yang tepat?

Pilih Brahma Relay MM 192.4 TW5/TS10 jika Anda membutuhkan kontrol pembakar gas otomatis untuk sistem dengan operasi intermiten. Pastikan aplikasi Anda sesuai dengan spesifikasi produk, yaitu untuk pembakar gas atmosferik atau kipas bantu. Produk ini memiliki penguncian non-volatile dan memerlukan reset manual, cocok untuk ketel uap, pemanas air, dan generator udara panas.

Di mana beli Brahma Relay MM 192.4 TW5/TS10 di Indonesia?

Anda dapat membeli Brahma Relay MM 192.4 TW5/TS10 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu. Hubungi kami untuk minta penawaran dan informasi lebih lanjut.

Digunakan dalam

Aplikasi umum untuk Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Produk

3G Electric memasok Brahma burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay SM 192.2 TW1.5/TS5
Brahma
Relay SM 192.2 TW1.5/TS5
Relay SM 592.2 TW10/TS10
Brahma
Relay SM 592.2 TW10/TS10
Relay CM 31F TW10/TS5
Brahma
Relay CM 31F TW10/TS5
Relay CM 32 TW1.5/TS10
Brahma
Relay CM 32 TW1.5/TS10
Relay CM 31 TW1.5/TS10
Brahma
Relay CM 31 TW1.5/TS10
Relay CM 31 TW20/TS10
Brahma
Relay CM 31 TW20/TS10

Lainnya dari Brahma

Lihat semua Brahma suku cadang
Relay G 22 S03N TV15/TS10
Brahma
Relay G 22 S03N TV15/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
FC 7/R cell
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735
Brahma
Brahma
Relay GR1 10.10