SITBurner Controls

Sit 0579308 control box (replaces 0577308)

SIT 0579308 adalah kontrol pembakar (burner control) elektronik dengan mikroprosesor yang dirancang untuk pemasangan terintegrasi pada katup multifungsi SIT SIGMA 840, 845, dan 848. Perangkat ini menggantikan model…

SKU 3G-CBM-06068

Juga terdaftar sebagai: REL 55014 · REL-55014

Merek
SIT
Item
0579308 control box
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

SIT
voltage
230 Vac
spark gap
2-4 mm
alarm current
1 A
connection type
Molex 2599
repetition rate
25 Hz
max cable length
1 m
protection degree
IP 40

Konten Lembar Data

NE SIT Group W 577 DBC ELECTRONIC BURNER CONTROL DEVICE WITH MICROPROCESSOR FOR INTEGRAL MOUNTING ON SIT SIGMA MULTIFUNCTIONAL CONTROLS Field of application Main features Home gas appliances such Gas burner ignition and Subject to change without notice as boilers (with natural or control functions integrated forced draught including and managed by digital dynamic control of the air technology (microprocessor). pressure switch), water heaters,hot air generators Reference standards and gas radiators. EN 298 with reference to 9.955.841 117 the “Gas Appliance Directive“ (GAD 90/396/EEC). w w w . s i t g r o u p . i t 577 DBC DESCRIPTION AND APPLICATION The 577 Digital Burner Control is a family of electronic devices with integrated functions for the safety and the control of combustion in home gas appliances and has the same functions of 537 ABC family, with which it is interchangeable. The 577 DBC is dedicated in particular to boilers, water heaters and hot air generators with both natural draught and fan assisted burners. All the functions are managed by a microprocessor and the product has obtained the certification of conformity with the most severe safety requirements. The microprocessor structure combines the traditional features of reliability with high flexibility for the needs of the appliance and a wide range of possibilities for further customisation with adds-on such as timers, multiple attempts and so on. The 577 DBC family of products has been specifically designed for fixing on SIT 840, 845 and 848 SIGMA multifunctional controls by means of an exclusive plastic box which integrates itself with the valve body and simplifies the connection of the solenoid valves. Further customisation is easy to achieve thanks to the digital technology. All the hardware and software architecture has been designed by SIT and innovative concepts and technologically advanced solutions have been implemented so as to enhance the device’s reliability and performances. BASIC FEATURES - Compact design - Direct assembly on the gas control - Incorporated igniter with EMC filter - Direct burner ignition (DBI) or by intermittent pilot (IP) - Manual reset function and remote signalling of the non-volatile lockout state - Multiple plug-in connectors - Utilises well established electronic technology for high reliability of operations - Precise and repeatable timings - Multiple ignition attempts - Flame detection by ionization - CE approval according to EN 298 standard - Repetition of the cycle after loss off flame during operation - Permanent lock-out visualization, a without thermostat input being present - Suitable for applications at wide ambient temperature range Options available - Fan and air pressure switch control - Volatile lockout version for specific applications - 230 VAC or optocoupled flame presence signal - Possibility to connect an automatic safety thermostat in series with the solenoid valve with manual lockout following its opening - Different flame current sensitivity options may be specified - Protection degree IP44 - Several pre-purge and safety timings can be tailored to the application. - Different frequency of ignition - Possibility of connection on phase-phase main supply power lines 2 577 DBC OPERATION Normal operation (natural draught or fan assisted) BOILERS WITH During the waiting or purge time, Tw or Tp, the unit verifies that there is NATURAL DRAUGHT DBI version no parasitic flame signal present, and that the internal circuitry is operating correctly. If the unit is used on a fan-assisted application, the air pressure switch is verified to be in the N.C. (normally closed) or MV “no flow” position. VN Upon powering the fan, the unit will not begin the operating sequence until the N.O. (normally open) or “flow” position is activated on the air pressure switch. After the scheduled waiting time Tw, or purge time Tp, the built-in igniter and the gas valve are energized. This commences the TW TW TS safety time, Ts. The ignition spark will ignite the gas and the flame will be sensed by the electrode. BOILERS WITH If there is no flame the system repeats the ignition cycle, after a defined NATURAL DRAUGHT interpurge time, for a definite number of times and it goes definitively on IP version lockout position in case there is no flame. Upon sensing the flame, the HV spark will be suppressed and the gas valve will remain energized. When the thermostat is open, the valve and EV1 fan are de-energized and the control returns to the stand-by mode. The EV2 safety time of the 577 DBC has a constant duration in all operating VN conditions and, in particular, does not depend on the moment the pressure switch is switched over. Resetting the unit TW TW TS To reset the unit the reset switch is depressed for one second at least and then released. FAN ASSISTED BOILERS DBI version EV WIRING DIAGRAM VN P TP TP TS 3 577 DBC TECHNICAL DATA AMBIENT WORKING TEMPERATURE -20 °C to +60 °C HUMIDITY 90 % max at 40 °C (not condensing) SUPPLY VOLTAGE 230 Vac - 15 %, + 10 %, 50-60 Hz POWER CONSUMPTION 20 VA ELECTRICAL RATINGS Gas valves: 230 Vac, 0.5 A, cosϕ≥0.4 Fan: 230 Vac, 1 A, cosϕ≥0.6 Alarm: 230 Vac, 1 A, cosϕ=1 ELECTRICAL CONNECTIONS High voltage probe: male fast-on connector 2.8 x 0.5 mm Flame detection probe: male fast-on connector 4.8 x 0.8 mm Other connections: male Molex series 2599 suitable for female Molex series 3001 and 3002 or compatible. PROTECTION DEGREE Standard IP 40 IP 44 with gaskets TIMING Minimum waiting time Tw or purge time Tp: 1 ... 60 sec. Maximum safety time Ts: 3 ... 120 sec. Ignition attemps 1 ... 10 Relative interpurge time 0 ... 240 sec. FLAME SENSING Minimum flame current: 0.5 µA Recommended flame current: > 3 times the minimum current FUSING Internal: 4 A fast. External: maximum 3.15 A fast or less depending on the electrical loads. This fuse protects the device in the event of overloading or short circuits and prevents the intervention of the internal fuse. IGNITION Ignition voltage: 15 KV at 30 pF load Repetition rate: 25 Hz standard (1 : 50 Hz) Max. length of the cable: 1 m Spark gap recommended: 2-4 mm MOUNTING Integrated on SIT SIGMA multifunctional gas controls. DIMENSIONS- 577 DBC with 845 SIGMA VERSION G3/4 ISO 228 SIT GROUP www.sitgroup.it - e-mail: marketing@sitgroup.it 4
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

SIT Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

SIT 0579308 adalah kontrol pembakar (burner control) elektronik dengan mikroprosesor yang dirancang untuk pemasangan terintegrasi pada katup multifungsi SIT SIGMA 840, 845, dan 848. Perangkat ini menggantikan model 0577308 dan berfungsi untuk pengapian serta kontrol pembakaran pada ketel uap (boiler) domestik, pemanas air, dan generator udara panas. Unit ini beroperasi pada tegangan 230 Vac dengan arus alarm 1 A, jarak percikan 2–4 mm, dan tingkat pengulangan 25 Hz, serta memiliki tingkat perlindungan IP 40. Produk ini merupakan suku cadang pembakar yang penting untuk sistem pemanas berbahan bakar gas di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi dari SIT 0579308 control box?

SIT 0579308 adalah kontrol pembakar elektronik dengan mikroprosesor yang mengelola pengapian dan kontrol pembakaran pada peralatan gas rumah tangga seperti ketel uap (boiler), pemanas air, dan generator udara panas. Perangkat ini dirancang untuk dipasang pada katup multifungsi SIT SIGMA 840, 845, dan 848.

Apa spesifikasi teknis SIT 0579308?

Spesifikasi teknis SIT 0579308 meliputi tegangan 230 Vac, jarak percikan 2–4 mm, arus alarm 1 A, tipe koneksi Molex 2599, tingkat pengulangan 25 Hz, panjang kabel maksimal 1 m, dan tingkat perlindungan IP 40. Produk ini memenuhi standar EN 298 dan GAD 90/396/EEC.

Apakah SIT 0579308 kompatibel dengan SIT 0577308?

Ya, SIT 0579308 adalah pengganti langsung untuk model 0577308. Keduanya memiliki fungsi yang sama dan dapat dipertukarkan. Kontrol pembakar ini dirancang untuk dipasang pada katup multifungsi SIT SIGMA 840, 845, dan 848.

Di mana beli SIT 0579308 di Indonesia?

Anda dapat membeli SIT 0579308 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda. Hubungi kami untuk minta penawaran.

Bagaimana cara memasang SIT 0579308 control box?

Pemasangan SIT 0579308 dilakukan dengan mengintegrasikannya ke katup multifungsi SIT SIGMA 840, 845, atau 848 menggunakan kotak plastik eksklusif yang disediakan. Koneksi menggunakan tipe Molex 2599 dengan panjang kabel maksimal 1 m. Pastikan tegangan suplai 230 Vac dan jarak percikan 2–4 mm.

Digunakan dalam

Aplikasi umum untuk SIT
Commercial boiler gas-control replacement — Sigma 845 / 848 on hot-water and steam boilers
Catering and commercial kitchen equipment — Eurosit 630 thermostatic valves on fryers, ovens, and steamers
Residential heating appliance service — NOVA 820 / 822 / 824 as OEM-replacement gas-control valves
Standing-pilot gas appliance refurbishment — Eurosit 630 and Minisit thermostatic controls
Industrial gas-fired process equipment — Sigma 848 modulating gas valves for burner integration

SIT Produk

3G Electric memasok SIT burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
SIT
SIT
Sit control box 0536007
SIT
SIT
Control box Sit 0537002
Satronic
Satronic
Cell 3008461 for 550 (replaces 3007492)
Satronic
Satronic
Relay CM391.2 10.5

Lainnya dari SIT

Lihat semua SIT suku cadang
Sit 0577211 control box
SIT
Sit 0577211 control box
SIT
SIT
Sit 0503501 control box
SIT
SIT
Sit control box 0537201
Sit 0577710 NO FAN DBI control box
SIT
Sit 0577710 NO FAN DBI control box
SIT
SIT
Sit control box 0503902
Sit control box 0537501
SIT
Sit control box 0537501
SIT
SIT
Sit control box 0537403
Control box Sit 0579311 replaces 0577311
SIT
Control box Sit 0579311 replaces 0577311