Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Satronic Relay CMG 8862 D2 (replaces RMG8862C2) - Burner Controls
SatronicBurner Controls

Satronic Relay CMG 8862 D2 (replaces RMG8862C2)

Relay CMG 8862 D2 dari Satronic adalah pengontrol pembakar (burner control) berbasis mikrokontroler yang dirancang untuk mengawasi pembakar gas atau minyak paksa (forced draft) satu atau beberapa tahap dalam operasi…

SKU 3G-CBM-06083

Juga terdaftar sebagai: REL 60120 · REL-60120

Merek
Satronic
Item
Relay CMG 8862 D2
Kategori
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Satronic
safety class
I
oil throughput
>30 kg/h
max cable length
2 m
max capacity gas
>120 kW
mounting position
optional
power consumption
20 VA
degree of protection
IP 20

Konten Lembar Data

7 136 ISO 9001 Burner Controls RMO88.53... RMG88.62... RMG/M88.62... Microcontroller-based burner controls for the supervision of single- or multi- stage forced draft gas / oil burners in intermittent operation. Oil throughput above 30 kg / h and a maximum capacity above 120 kW when fir- ing on gas. The RMO88.53... / RMG88.62... / RMG/M88.62... and this Data Sheet are intended for OEMs which integrate the burner controls in their products. Use, features Use The burner controls are designed for the startup and supervision of single- or multi- stage forced draft burners in intermittent operation. The RMO88.53... is for use with forced draft oil burners, the RMG88.62... / RMG/M88.62... for forced draft gas burners. When firing on oil, yellow-burning flames are supervised with photoresistive detectors QRB1B..., and blue-burning flames with blue-flame detectors QRC... When firing on gas, the flame is supervised with an ionization probe or flame detector QRA... (with ancillary unit AGQ2...A27). Firing on oil - Forced draft oil burners to EN 267 - Burner controls for use with atomization oil burners of monoblock design to EN 230 Firing on gas - Forced draft gas burners to EN 676 - Burner controls to EN 298 CC1N7136en Riello Siemens Building Technologies 11.12.2002 HVAC Products Application-specific When firing on oil features - Contact for preheating the oil - Monitoring of time for preheating the oil - Limitation of the number of repetitions When firing on gas - Monitoring of air pressure with functional check of the air pressure switch during startup and operation General - Undervoltage detection - Electrical remote reset - Accurate and reproducible program sequence owing to digital signal handling - Controlled intermittent operation after 24 hours of continuous operation - Multicolor display of status and error messages Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not open, interfere with or modify the unit! · Before performing any wiring changes in the connection area, completely isolate the burner control from the mains supply (all-polar disconnection) · Ensure protection against electric shock hazard by providing adequate protection for the burner control’s terminals · Check to ensure that wiring is in an orderly state and that the wires are firmly con- nected · Press the lockout reset button of the burner control or the reset button extension AGK20.43 only manually (applying a force of no more than 10 N), without using any tools or pointed objects · Fall or shock can adversely affect the safety functions. Such units may not be put into operation, even if they do not exhibit any damage Engineering notes · When used in connection with actuators, there is no position feedback signal from the actuator to the burner control · The running times of the actuators must match the burner control’s program. An additional safety check of the burner control together with the actuators is required Mounting notes · Ensure that the relevant national safety regulation are complied with 2/21 Siemens Building Technologies CC1N7136en HVAC Products Riello 11.12.2002 Installation notes · Installation work must be carried out by qualified staff · Observe the permissible lengths of the detector cables (refer to «Technical data») · Always run the high-voltage ignition cables separately while observing the greatest possible distances to the unit and to other cables · Install switches, fuses, earthing, etc., in compliance with local regulations · Ensure that the maximum permissible current ratings will not be exceeded (refer to «Technical data») · Do not feed external mains voltage to the control outputs of the unit. When testing the devices controlled by the burner control (fuel valves, etc.), the burner control must never be connected · Phase and neutral conductors may not be interchanged Electrical connection of ionization probe and flame detector It is important to achieve practically disturbance- and loss-free signal transmission: · The cable length must not exceed 1 m · Never run the detector cable together with other cables – Line capacitance reduces the magnitude of the flame signal – Use a separate cable · Insulation resistance – Must be a minimum of 50 MW between ionization probe and ground – Soiled detector holders reduce the insulation resistance, thus supporting creep age currents · Earth the burner in compliance with the relevant regulations; earthing the boiler alone does not suffice Only when firing on gas · Observe the polarity With supervision of the ionization current, the burner controls can detect wrong polarity of live and neutral conductors, in which case they initiate lockout at the end of «TSA» · The ionization probe must be protected against electric shock hazard · Locate the ionization probe such that – the ignition spark cannot arc over to the ionization probe (risk of electrical overloads) – the ignition spark cannot adversely affect supervision of the ionization current · In networks with nonearthed neutral conductor and ionization current supervision, terminal 6 must be connected to burner ground 3/21 Siemens Building Technologies CC1N7136en HVAC Products Riello 11.12.2002 Commissioning notes · Commissioning work must be carried out by qualified staff · When commissioning the plant or when doing maintenance work, make the follow- ing safety checks: Safety check Anticipated response a) Burner startup with flame detector darkened or Lockout at the end of «TSA» with open-circuit to the ionization probe b) Burner startup with flame detector exposed to Lockout after no more than extraneous light (only when firing on oil) 25 seconds or immediate lockout during the prepurge time c) Burner operation with simulated flame failure; for Firing on oil: Repetition followed that purpose, darken the flame detector during by lockout at the end of «TSA» operation and maintain that status or interrupt Firing on gas: immediate lockout the gas supply after the flame has extinguished d) Burner startup with response from air pressure Lockout at the end of the waiting switch (only when firing on gas) time «tw» e) Burner operation with simulated loss of air pres- Immediate lockout sure (only when firing on gas) Standards Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) 89 / 336 EEC - Directive for gas-fired appliances 90 / 396 EEC - Low-voltage directive 73 / 23 EEC Service notes · Maintenance work must be carried out by qualified staff · Each time a unit has been replaced, check to ensure that wiring is in an orderly state and that the wires are firmly connected. Make the safety checks as listed in «Commissioning notes» Disposal notes The unit contains electrical and electronic components and may not be disposed of together with household waste. Local and currently valid legislation must be observed. Mechanical design The housing of the burner controls is made of impact-proof, heat-resistant and flame- retarding plastic. The housing accommodates the - microcontroller which controls the program sequence, and the relays for load con- trol - electronic…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Satronic Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Relay CMG 8862 D2 dari Satronic adalah pengontrol pembakar (burner control) berbasis mikrokontroler yang dirancang untuk mengawasi pembakar gas atau minyak paksa (forced draft) satu atau beberapa tahap dalam operasi intermiten. Dengan konsumsi daya 20 VA, perlindungan IP 20, dan throughput minyak di atas 30 kg/jam serta kapasitas gas di atas 120 kW, relay ini cocok untuk aplikasi pembakar industri di Indonesia. Produk ini menggantikan model RMG8862C2 dan merupakan suku cadang pembakar yang andal untuk sistem ketel uap dan peralatan pembakaran lainnya.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi Relay CMG 8862 D2 Satronic?

Relay CMG 8862 D2 dari Satronic berfungsi sebagai pengontrol pembakar untuk memulai dan mengawasi pembakar gas atau minyak paksa satu atau beberapa tahap dalam operasi intermiten. Produk ini menggantikan RMG8862C2 dan memiliki konsumsi daya 20 VA serta perlindungan IP 20.

Apa spesifikasi teknis Relay CMG 8862 D2?

Spesifikasi teknis Relay CMG 8862 D2 meliputi kelas keamanan I, throughput minyak di atas 30 kg/jam, kapasitas gas di atas 120 kW, panjang kabel maksimal 2 m, konsumsi daya 20 VA, dan tingkat perlindungan IP 20. Posisi pemasangan bersifat opsional.

Di mana beli Relay CMG 8862 D2 di Indonesia?

Anda dapat membeli Relay CMG 8862 D2 Satronic melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih Relay CMG 8862 D2 yang tepat?

Pastikan Relay CMG 8862 D2 sesuai dengan aplikasi pembakar Anda, baik untuk gas atau minyak. Periksa spesifikasi seperti throughput minyak di atas 30 kg/jam dan kapasitas gas di atas 120 kW. Produk ini cocok untuk pembakar paksa satu atau beberapa tahap dalam operasi intermiten.

Apakah Relay CMG 8862 D2 kompatibel dengan pembakar gas?

Ya, Relay CMG 8862 D2 dirancang untuk pembakar gas paksa sesuai EN 676 dan EN 298. Produk ini mengawasi nyala api menggunakan probe ionisasi atau detektor QRA dengan unit tambahan AGQ2...A27. Kapasitas gas maksimal di atas 120 kW.

Digunakan dalam

Aplikasi umum untuk Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Produk

3G Electric memasok Satronic burner controls. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay RMG508
Satronic
Satronic
Relay CM391.2 10.5
Relay 552 SE
Satronic
Relay 552 SE
Relay 553 SE
Satronic
Relay 553 SE
Satronic
Satronic
Relay DMG 972-N MOD.01
Relay 550 SE
Satronic
Relay 550 SE

Lainnya dari Satronic

Lihat semua Satronic suku cadang
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)