Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
COFIIgnition Transformers

COFI Transformer type TC1 100%

Transformator pengapian COFI tipe TC1 100% adalah komponen peralatan pembakaran yang dirancang untuk menghasilkan tegangan frekuensi tinggi hingga 15 KV puncak guna menyalakan api pada pembakar industri gas atau…

SKU 3G-CBM-06969

Juga terdaftar sebagai: TRF 10003 · TRF-10003

Merek
COFI
Item
Transformer type TC1 100%
Kategori
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

COFI
electrode distance
3-5 mm
max ignition cable length
1.5 m
operating temperature range
-10°C to +60°C
standard supply cable length
560 mm

Konten Lembar Data

ELECTRONIC IGNITION TRANSFORMERS Types TC....A. TC….S. TD….A. TD….S. DESCRIPTION This range of electronic ignition transformers is characterized by extremely limited overall dimensions and is particularly suitable to equip forced draught burners for gas and light or heavy oil, for civil and industrial applications. The TC..S. and TD..S. models are particularly suitable to equip water cleaners. The TD… models have reduced overall dimensions and therefore they are useful to equip applications with little room available. The working principle is due to the generation of high frequency voltage by means of an electronic oscillator; the resulting voltage is then increased by using a winding with ferrite nucleus. In this way it is possible to reach output voltage values up to 15 KV. All types can be supplied with filter to minimize the emission of electromagnetic interference. In this way this series of electronic transformers is in compliance with the directive 89/336/EEC without the use of external filters. The transformers of this series are suitable for intermittent operation, i.e. 50% duty cycle (TC..A. and TD..A.), or for permanent operation (TC..S. and TD..S.). FEATURES Followings are the main features of this range of transformers: − available with inbuilt anti-emission filter; − limited weight and overall dimensions; − high efficiency and ignition power; − low consumption; − single pole or dual pole high voltage output; − different fixing and connecting systems. TECHNICAL DATA TC1...A - TD1…A TC1..AF – TD1..AF TC2...A – TD2…A TC2..AF – TD2..AF Number of poles 1 1 2 2 Output peak voltage KV (1) 15 15 2x10 2x10 Output effective voltage KV (1) 9 9 2x5 2x5 Output peak current mA (2) 45 45 55 55 Output effective current mA (2) 25 25 30 30 Output voltage frequency kHz (1) 6 6 6 6 Output voltage frequency kHz (2) 10 10 10 10 Inbuilt filter • • Consumption VA (3) 45 45 55 55 TC1...S - TD1…S TC1..SF – TD1..SF TC2...S – TD2…S TC2..SF – TD2..SF Number of poles 1 1 2 2 Output peak voltage KV (1) 15 15 2x10 2x10 Output effective voltage KV (1) 9 9 2x5 2x5 Output peak current mA (2) 45 45 55 55 Output effective current mA (2) 15 15 18 18 Output voltage frequency kHz (1) 6 6 8,5 8,5 Output voltage frequency kHz (2) 10 10 12 12 Inbuilt filter • • Consumption VA (3) 25 25 30 30 (1) Open-circuit secondary with 30pF charge. (2) Short-circuit secondary. (3) 10mm discharge distance. - Supply voltage: 220/240V-50/60Hz Versions with inbuilt anti-emission filter: on request: 110/120V-50/60Hz - Operating cycle: (TC..A. – TD..A.) 50% in 2 minutes TX X X X X X F (TC..S. – TD..S.) 100%       - Operating temperature range: -10°C +60°C      → A: 50% duty cycle - Recommended distance between      S: 100% duty cycle the electrodes: 3÷5 mm      - Max. ignition cable length: 1.5 m     → C: output with cable (Fig.1-2-4) - Standard supply cable length: 560 mm     P: output with outlet (Fig.3-5) - Weight: about 370 g        → V: screw fixing system (Fig.7) CONSTRUCTION    T: fixing system with terminal ∅ 4 (Fig.7) The working principle based on the use of a high frequency    electronic oscillator has allowed to realize a device with limited dimensions and weight, but with high ignition power.   → L: lateral isolators The electronic circuit and the transformer with ferrite nucleus   S: bottom isolators are bathed in a special kind of resin with good thermal  ↓ conductivity and a specific coefficient of expansion, which  1: single pole grants high resistance to temperature variations and to the  2: dual pole overload due to protracted working. ↓ An inbuilt varistor protects the appliance from possible voltage C, D: box type (Fig.1÷5) transients in the electric network. The transformers of this series are available in different For instance, the denomination TC2LVPAF indicates that this executions as regards the number of poles, the position of the type of transformer is provided with two lateral isolators, isolators, the type of connection and output and the presence screw fixing system, output with outlet and anti-emission filter. of anti-emission filter; on this subject, see the following schemes: OVERALL DIMENSIONS Fig.1-2-3-4-5 show the main overall dimensions of these standard versions: transformers. To fix the TC.. models transformers (Fig.1-2) screws type T X X X X X X → A: 50% duty cycle M4x40 or M5x40 must be used; the oval fixing holes permit a      S: 100% duty cycle variation of the wheel base between 57 mm and 64 mm. To      fix the TD.. models transformers (Fig.3-4-5) screws type     → C: output with cable (Fig.1-2-4) M3x40 or M4x40 must be used.     P: output with outlet (Fig.3-5)        → V: screw fixing system (Fig.7)    T: fixing system with terminal ∅ 4 (Fig.7)      → L: lateral isolators   S: bottom isolators  ↓  1: single pole  2: dual pole ↓ C, D: box type (Fig.1÷5) TD2L Fig. 3 Fig. 1 TD1L Fig.4 TD2S Fig. 5 CONNECTION This range of ignition transformers has been designed in order to be used with control boxes of our own production, which can be mounted on the ignition devices by means of fixing screws type M4x45, as shown in Fig.6. Fig.2 ANTI-EMISSION FILTER With particular reference to the use of ignition transformers on oil or gas burners, you will find here below some remarks about the application of these devices, resulting from the research carried out by the Brahma Testing Laboratory. This Laboratory, in compliance with EN55014 and with CISPR 16- 1, is adequately equipped for the measuring of electromagnetic interference on boilers, burners, warm air generators and heating systems in general. According to the directive 89/336/EEC, the above mentioned products are subjected to the measuring of conducted electromagnetic interference in the power network, irradiated by the supply cable; the measuring is carried out on the basis of a frequency range from 150KHz to 30MHz in case of conducted interference, and from 30 to 300MHz in case of irradiated interference. Fig. 6 Electromagnetic interference is mainly due to power variations in the electric circuits (i.e. current peaks); the greater and The connection of high voltage cables can be of two types, faster these variations, the higher the interference. In this according to the terminals used inside the isolators: case, the main source of interference is the…
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

COFI Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Transformator pengapian COFI tipe TC1 100% adalah komponen peralatan pembakaran yang dirancang untuk menghasilkan tegangan frekuensi tinggi hingga 15 KV puncak guna menyalakan api pada pembakar industri gas atau minyak. Dengan jarak elektroda 3-5 mm dan panjang kabel pengapian maksimal 1,5 m, unit ini beroperasi pada rentang suhu -10°C hingga +60°C dan dilengkapi kabel suplai standar sepanjang 560 mm. Cocok untuk aplikasi ketel uap dan pembakar komersial, transformator ini menawarkan efisiensi tinggi dengan konsumsi daya rendah.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa transformator pengapian COFI TC1 100% digunakan?

Transformator pengapian COFI TC1 100% digunakan untuk menghasilkan percikan tegangan tinggi (hingga 15 KV puncak) pada pembakar industri gas atau minyak, baik untuk aplikasi sipil maupun industri. Produk ini ideal untuk pembakar dengan hembusan paksa dan tersedia dalam model operasi intermiten (50% siklus kerja) atau permanen.

Apa spesifikasi teknis transformator COFI TC1 100%?

Spesifikasi teknis COFI TC1 100% meliputi: tegangan output puncak 15 KV, tegangan efektif 9 KV, arus puncak 45 mA, frekuensi output 6-10 kHz, jarak elektroda 3-5 mm, panjang kabel pengapian maksimal 1,5 m, suhu operasi -10°C hingga +60°C, dan panjang kabel suplai standar 560 mm.

Bagaimana cara memilih transformator pengapian yang tepat untuk pembakar industri?

Pilih transformator pengapian berdasarkan jumlah kutub (single atau dual), tegangan output yang dibutuhkan (COFI TC1 100% menawarkan 15 KV puncak), dan jenis operasi (intermiten atau permanen). Pastikan jarak elektroda 3-5 mm dan panjang kabel pengapian tidak melebihi 1,5 m sesuai spesifikasi COFI.

Di mana beli transformator COFI TC1 100% di Indonesia?

Anda dapat membeli transformator pengapian COFI TC1 100% melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan suku cadang pembakar sampai ke lokasi industri Anda dengan aman.

Digunakan dalam

Aplikasi umum untuk COFI
Gas burner combustion — TRS 515 PC/S, TRS 610 PC/S, TRS 830 P/S ignition transformers for spark generation in small to large capacity gas-fired heaters and boilers.
Oil-fired heating systems — TRE 820/S1 oil-immersed transformer for reliable ignition in heavy fuel oil and light fuel oil burners in industrial plants.
Dual-fuel burner control — TRS 610 PC/S for burners switchable between gas and oil, requiring consistent high-voltage spark across both fuel modes.
Burner retrofit and maintenance — Replacement ignition transformers and mounting kits for aging or damaged combustion control systems in existing boiler houses.
High-voltage spark generation — TRG 1035/S dual-output transformer for complex ignition circuits requiring multiple spark electrodes or redundant ignition paths.
Panel-mounted combustion control — Column 12X38 and Spina cable assemblies for compact transformer installation in enclosed burner management control panels.

COFI Produk

3G Electric memasok COFI ignition transformers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
COFI
COFI
Transformer type TC1 33%
COFI
COFI
Transformer type TC1 LVCA
COFI
COFI
Transformer type T13M
COFI
COFI
Transformer type TC2 LVCSF
Gas transformer TRK1-20 PC/VD 100%
COFI
Gas transformer TRK1-20 PC/VD 100%
COFI
COFI
Transformer type T13M 110V

Lainnya dari COFI

Lihat semua COFI suku cadang
COFI
COFI
Transformer type AR1
COFI
COFI
Transformer TD2 LT CSF Oil 2x12kw
Fuel transformer TRS 820/2/J
COFI
Fuel transformer TRS 820/2/J
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
Transformer TD2 LVA Oil 2x12kw - 50%
COFI
COFI
Transformer type TC1 LTCA
COFI
COFI
Transformer TD2 ST PAF oil 2x12KV
COFI
COFI
Transformer type T11 110 volts
Oil transformer TRS 1030/S
COFI
Oil transformer TRS 1030/S