Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Brahma T11/M type transformer - Ignition Transformers
BrahmaIgnition Transformers

Brahma T11/M type transformer

Transformator pengapian Brahma T11/M adalah komponen penting untuk sistem pembakaran bahan bakar cair atau gas pada pembakar industri. Dengan konsumsi daya 1x9 VA dan output puncak 240 VA, transformator ini dirancang…

SKU 3G-CBM-06973

Juga terdaftar sebagai: TRF 10010 · TRF-10010

Merek
Brahma
Item
T11/M type transformer
Kategori
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Brahma
type
T11/M
duty cycle
standard
consumption va
1x9
output peak va
240
number of poles
1
electrode distance mm
3-5
supply cable length mm
550

Konten Lembar Data

IGNITION DESCRIPTION TRANSFORMERS Ignition transformers series T11 and T16 are suitable for fluid or gaseous fuel burners. Ignition transformers series T13 and T17, with 100% duty- cycle, are particularly suitable for the application on industrial machines (e.g. water cleaners). Type T11 and T13 FEATURES Followings are the main features of this series: - various connection and fixing systems; - high discharge power (they are particularly suitable in all those applications in which long ignition wires are required); - high efficiency and ignition power. TECHNICAL DATA - Supply voltage: 220V - 50Hz (different voltage and frequency values are available on request) - Operating temperature range: -10°C +60°C - Isolation: polyester resin - Recommended distance between Type T16 and T17 the electrodes: 3 ÷ 5 mm - Supply cable standard length: 550 mm T11/... T13/… T16/... T17/... Number of poles 1 1 2 2 Output peak 1x9 1x8 2x5 2x4 voltage (KV) Output effective 20 16 20 16 current (mA) (1) Input effective 1,1 0,65 1,1 0,7 current (A) 33% in 3 33% in 3 Duty cycle 100% 100% minutes minutes Power 240 145 240 155 consumption (VA) Weight (Kg) 2 2 2 2 (1) : short circuit secondary. CONSTRUCTION The magnetic circuit across the transformer is mantle- shaped (see general features in Figure 1 and Figure 2). The secondary windings are center grounded. The transformer is provided with a radio interference suppression shield, which for its effectiveness must be connected to a good ground. Two fire painted caps cover the coils and form a whole with the magnetic circuit. Each transformer is detected by the fixed letter T (transformer), by a series of numbers that indicate the model and possibly by a letter of the alphabet which determines a particular fixing system: 29087_r00 1/3 CONNECTION T XX / X   The high voltage isolators employed in this series of  → fixing system transformers are of two different types, according as the → model connection with high voltage cables occurs by means of a screw, 4 mm diameter cylindrical terminal or of a 6.3 mm diameter cylindrical terminal. If the fixing system used is standard, the corresponding If not expressly mentioned, the connection terminal used is reference letter is not inserted in the part reference. a screw terminal. The insulators are made of PBT. For instance, the part reference T11 refers to a transformer with standard fixing system, whereas the part reference T11/B corresponds to a T11 transformer with different fixing system INSTALLATION (see table 1, type B). - Connect and disconnect the ignition transformer only after The transformers of this series can have the same electric switching off the power supply. features but different fixing systems, or vice versa. - Respect the applicable national and European standards (e.g. EN 60355-1 / EN 50165) regarding electrical safety. OVERALL DIMENSIONS - Make sure that the earth of the transformer and the earth of the electric system are well connected. Figures 1 and 2 show the main overall dimensions and Table 1 the various transformers fixing systems. - The device can be mounted in any position. - Do not put high voltage cables next to other cables. - Guarantee a protection degree suitable to the application. T11/… - T13/… primary coil Noise shield Magnetic shunt secondary coil Alimentation cable magnetic circuit Figure 1 T16/… - T17/… primary coil Noise shield secondary coil Magnetic shunt Alimentation cable magnetic circuit Figure 2 2/3 29087_r00 FIXING SYSTEMS T…/B T…/N T…/NC T…/M T…/MC T…/F - T…/C T…/R T…/RC T…/W T…/AN Table 1 Note : The images are representative and should therefore be considered only for fixing purpose. NOTES ABOUT PRODUCT DISPOSAL The device contains electronic components and cannot therefore be disposed of as normal household waste. For the disposal procedure, please refer to the local rules in force for special waste. ATTENTION -> Brahma S.p.A. accepts no responsibility for any damage resulting from customer tampering with the product. 23/09/2016 Subject to amendments without notice 3/3
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Brahma Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Transformator pengapian Brahma T11/M adalah komponen penting untuk sistem pembakaran bahan bakar cair atau gas pada pembakar industri. Dengan konsumsi daya 1x9 VA dan output puncak 240 VA, transformator ini dirancang untuk memberikan percikan api yang andal pada jarak elektroda 3–5 mm. Model satu kutub (1 pole) ini dilengkapi kabel suplai sepanjang 550 mm dan cocok digunakan sebagai suku cadang pembakar untuk berbagai aplikasi industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa transformator Brahma T11/M digunakan?

Transformator Brahma T11/M digunakan sebagai transformator pengapian pada pembakar industri bahan bakar cair atau gas. Fungsinya adalah menghasilkan tegangan tinggi untuk menyalakan api pada ketel uap, tungku, atau peralatan pembakaran lainnya. Produk ini memiliki output puncak 240 VA dan jarak elektroda 3–5 mm.

Apa spesifikasi transformator Brahma T11/M?

Spesifikasi Brahma T11/M meliputi: tipe T11/M, konsumsi daya 1x9 VA, output puncak 240 VA, jumlah kutub 1, jarak elektroda 3–5 mm, dan panjang kabel suplai 550 mm. Transformator ini memiliki duty cycle standar 33% dalam 3 menit dan tegangan suplai 220V 50Hz.

Di mana beli transformator Brahma T11/M di Indonesia?

Anda dapat membeli transformator Brahma T11/M melalui 3G Electric, distributor resmi yang memasok peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk pengiriman ke berbagai wilayah di Indonesia. Hubungi kami untuk minta penawaran.

Bagaimana cara memilih transformator pengapian yang tepat?

Untuk memilih transformator pengapian yang tepat, perhatikan spesifikasi seperti jumlah kutub, output peak voltage, dan jarak elektroda. Brahma T11/M memiliki 1 kutub dengan output puncak 240 VA dan jarak elektroda 3–5 mm, cocok untuk aplikasi pembakar industri dengan kebutuhan pengapian standar.

Digunakan dalam

Aplikasi umum untuk Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Produk

3G Electric memasok Brahma ignition transformers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Brahma T11/M Ignition Transformer
CBM
Brahma T11/M Ignition Transformer
Brahma: Ignition Transformer T11M-110V
Brahma
Brahma: Ignition Transformer T11M-110V
COFI
COFI
Transformer type T11 110 volts
Brahma: Ignition Transformer T11M-220V
Brahma
Brahma: Ignition Transformer T11M-220V
Brahma: Ignition Transformer T8
Brahma
Brahma: Ignition Transformer T8
COFI
COFI
Transformer type T13M

Lainnya dari Brahma

Lihat semua Brahma suku cadang