Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green - Servo Motor Feedback Cables
CHAINFLEXServo Motor Feedback Cables

CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green

The CHAINFLEX Measuring System Cable (MPN CF113-005-D) is a servo motor feedback cable with a conductor grouping of (4) Pair 26 AWG/(4) 20 AWG, a green PUR jacket, and no included ground. It is available by the foot…

SKU 3G-OTH-47779

Merek
CHAINFLEX
Item
Measuring System Cable:
Kategori
Servo Motor Feedback Cables
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

CHAINFLEX
Manufacturer Part Number
CF113-005-D
Type
Green, PUR Jacket
Overall Length
Order by the Foot
Includes Ground
No
Conductor Grouping
(4) Pair 26 AWG/(4) 20 AWG
Minimum Bend Radius Factor - Fixed
4 x OD
Minimum Bend Radius Factor - Flexible
6 x OD
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

CHAINFLEX Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The CHAINFLEX Measuring System Cable (MPN CF113-005-D) is a servo motor feedback cable with a conductor grouping of (4) Pair 26 AWG/(4) 20 AWG, a green PUR jacket, and no included ground. It is available by the foot and features a minimum bend radius factor of 4 x OD for fixed installations and 6 x OD for flexible applications.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the CHAINFLEX Measuring System Cable used for?

The CHAINFLEX Measuring System Cable (MPN CF113-005-D) is a servo motor feedback cable designed for industrial automation and motion control applications. It transmits signals from encoders or resolvers to drives in cable carriers, robotics, and machine tools where continuous flexing occurs.

What are the specifications of the CHAINFLEX CF113-005-D cable?

The CHAINFLEX CF113-005-D has a conductor grouping of (4) Pair 26 AWG/(4) 20 AWG, a green PUR jacket, and no included ground. It is sold by the foot. Minimum bend radius factor is 4 x OD for fixed and 6 x OD for flexible installations.

Where to buy CHAINFLEX Measuring System Cable worldwide?

3G Electric supplies the CHAINFLEX Measuring System Cable (CF113-005-D) worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to select the right CHAINFLEX servo feedback cable?

Select the CHAINFLEX cable based on conductor count, AWG size, jacket material, and flex requirements. For continuous motion applications, ensure the bend radius factor matches your installation (4 x OD fixed, 6 x OD flexible). Verify compatibility with your drive and encoder system.

Digunakan dalam

Aplikasi umum untuk CHAINFLEX
Automated assembly lines — Chainflex CF10 control cables for signal transmission in cable carriers
Robotic arms — Chainflex CF280ULH servo motor cables for power and feedback in high-flex joints
Material handling conveyors — Chainflex CF78-UL control cables with PUR jacket for oil resistance
CNC machining centers — Chainflex CF9-UL control cables rated at 1,000 V for spindle and axis control
Packaging machinery — Chainflex CFBUS-PVC-021 bus cables for CAN-Bus communication in continuous motion
Automotive manufacturing — Chainflex CF2 control cables with UV-resistant PUR jacket for outdoor gantry systems

CHAINFLEX Produk

3G Electric memasok CHAINFLEX servo motor feedback cables. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
CHAINFLEX Measuring System Cable: (5) Pr 26 AWG (0.14)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-027-D). Key specifications — Conductor Grouping: (5) Pair 26 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (5) Pr 26 AWG (0.14)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-027-D). Key specifications — Conductor Grouping: (5) Pair 26 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) 26 AWG (0.14)/(2) Pr 22 AWG (0.34), Green, PUR Jacket (MPN CF111-024-D). Key specifications — Conductor Grouping: (4) 26 AWG/(2) Pair 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) 26 AWG (0.14)/(2) Pr 22 AWG (0.34), Green, PUR Jacket (MPN CF111-024-D). Key specifications — Conductor Grouping: (4) 26 AWG/(2) Pair 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) Pr 22 AWG (0.34)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-011-D). Key specifications — Conductor Grouping: (4) Pair 22 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) Pr 22 AWG (0.34)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-011-D). Key specifications — Conductor Grouping: (4) Pair 22 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (5) Pr 26 AWG (0.14)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF111-027-D). Key specifications — Conductor Grouping: (5) Pair 26 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (5) Pr 26 AWG (0.14)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF111-027-D). Key specifications — Conductor Grouping: (5) Pair 26 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF894-015). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 8 x OD; Minimum Bend Radius Factor - Flexible: 12 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF894-015). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 8 x OD; Minimum Bend Radius Factor - Flexible: 12 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (3) Pr 26 AWG (0.14)/(2) 22 AWG (0.50), Green, PUR Jacket (MPN CF113-038-D). Key specifications — Conductor Grouping: (3) Pair 26 AWG/(2) 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (3) Pr 26 AWG (0.14)/(2) 22 AWG (0.50), Green, PUR Jacket (MPN CF113-038-D). Key specifications — Conductor Grouping: (3) Pair 26 AWG/(2) 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.

Lainnya dari CHAINFLEX

Lihat semua CHAINFLEX suku cadang
CHAINFLEX Measuring System Cable: (2) Pr 26 AWG (0.15)/(2) 22 AWG (0.38), Green, PUR Jacket (MPN CF111-028-D). Key specifications — Conductor Grouping: (2) Pair 26 AWG/(2) 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (2) Pr 26 AWG (0.15)/(2) 22 AWG (0.38), Green, PUR Jacket (MPN CF111-028-D). Key specifications — Conductor Grouping: (2) Pair 26 AWG/(2) 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: Green, PVC Jacket, 50 V Volt (MPN CF211-006). Key specifications — Conductor Grouping: (3) Shielded Twisted Pair 26 AWG/(4) 26 AWG/(4) 24 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: Green, PVC Jacket, 50 V Volt (MPN CF211-006). Key specifications — Conductor Grouping: (3) Shielded Twisted Pair 26 AWG/(4) 26 AWG/(4) 24 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-015-D). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 20 AWG (0.50), Green, PUR Jacket (MPN CF113-015-D). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (2) Pr 22 AWG (0.34), Green, TPR Jacket, 50 V Volt (MPN CF11-007-D). Key specifications — Conductor Grouping: (2) Pair 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (2) Pr 22 AWG (0.34), Green, TPR Jacket, 50 V Volt (MPN CF11-007-D). Key specifications — Conductor Grouping: (2) Pair 22 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) Pr 24 AWG (0.25)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF111-009-D). Key specifications — Conductor Grouping: (4) Pair 24 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) Pr 24 AWG (0.25)/(2) 20 AWG (0.50), Green, PUR Jacket (MPN CF111-009-D). Key specifications — Conductor Grouping: (4) Pair 24 AWG/(2) 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (3) Pr 24 AWG (0.25), Green, TPR Jacket, 50 V Volt (MPN CF11-008-D). Key specifications — Conductor Grouping: (3) Pair 24 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (3) Pr 24 AWG (0.25), Green, TPR Jacket, 50 V Volt (MPN CF11-008-D). Key specifications — Conductor Grouping: (3) Pair 24 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (3) Pr 26 AWG (0.14)/(2) 17 AWG (1.0), Green, TPR Jacket (MPN CF11-003-D). Key specifications — Conductor Grouping: (3) Pair 26 AWG/(2) 17 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (3) Pr 26 AWG (0.14)/(2) 17 AWG (1.0), Green, TPR Jacket (MPN CF11-003-D). Key specifications — Conductor Grouping: (3) Pair 26 AWG/(2) 17 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Brand: CHAINFLEX.
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 26 AWG (0.14)/(4) Shielded 20 AWG (0.50) (MPN CF111-004-D). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 26 AWG/(4) Shielded 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.
CHAINFLEX
CHAINFLEX Measuring System Cable: (4) Pr 26 AWG (0.14)/(4) 26 AWG (0.14)/(4) Shielded 20 AWG (0.50) (MPN CF111-004-D). Key specifications — Conductor Grouping: (4) Pair 26 AWG/(4) 26 AWG/(4) Shielded 20 AWG; Includes Ground: No; Overall Length: Order by the Foot; Minimum Bend Radius Factor - Fixed: 5 x OD; Minimum Bend Radius Factor - Flexible: 8 x OD; Brand: CHAINFLEX.