Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dayton Kipas Pembuangan Atap Upblast Aksial: Penggerak Sabuk, Bilah 48 in, 25.642 cfm, ODP - Emergency Smoke Belt-Drive Fans with Drive
DaytonEmergency Smoke Belt-Drive Fans with Drive

Dayton Kipas Pembuangan Atap Upblast Aksial: Penggerak Sabuk, Bilah 48 in, 25.642 cfm, ODP

Dayton Axial Upblast Roof Exhaust Fan dengan tipe Emergency Smoke Belt-Drive Fans with Drive adalah kipas pembuangan atap industri yang dirancang untuk aplikasi ventilasi darurat dan asap. Dilengkapi motor ODP 2 hp…

SKU 3G-OTH-81419

Merek
Dayton
Item
Kipas Pembuangan Atap Upblast Aksial: Penggerak Sabuk, Bilah 48 in, 25.642 cfm, ODP
Kategori
Emergency Smoke Belt-Drive Fans with Drive
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dayton
Type
25,642 cfm, ODP, 2 hp, 3
AC
208-230/460V
Blade
48 in
Number of Speeds
1
Nameplate Voltage
208-230/460V AC

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dayton Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Dayton Axial Upblast Roof Exhaust Fan dengan tipe Emergency Smoke Belt-Drive Fans with Drive adalah kipas pembuangan atap industri yang dirancang untuk aplikasi ventilasi darurat dan asap. Dilengkapi motor ODP 2 hp, 3 fase, 208-230/460V AC dengan satu kecepatan, kipas ini memiliki blade 48 in dan kapasitas aliran udara 25,642 cfm. Produk ini cocok untuk kebutuhan ventilasi pabrik, gudang, atau area industri di Indonesia yang memerlukan sistem pembuangan asap andal.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi Dayton Axial Upblast Roof Exhaust Fan 7M7V3?

Dayton Axial Upblast Roof Exhaust Fan 7M7V3 memiliki spesifikasi: motor ODP 2 hp, 3 fase, tegangan 208-230/460V AC, satu kecepatan, blade 48 in, dan kapasitas 25,642 cfm. Tipe ini adalah Emergency Smoke Belt-Drive Fans with Drive, cocok untuk ventilasi darurat.

Untuk apa Dayton Axial Upblast Roof Exhaust Fan digunakan?

Kipas ini digunakan untuk pembuangan asap dan ventilasi darurat di atap bangunan industri seperti pabrik, gudang, atau area komersial. Dengan kapasitas 25,642 cfm dan blade 48 in, ia mampu mengeluarkan udara panas dan asap secara efisien saat kondisi darurat.

Di mana beli Dayton Axial Upblast Roof Exhaust Fan di Indonesia?

Anda dapat membeli Dayton Axial Upblast Roof Exhaust Fan 7M7V3 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Bagaimana cara memilih kipas exhaust atap yang tepat untuk industri?

Pilih kipas berdasarkan kapasitas cfm yang dibutuhkan, ukuran blade, dan tegangan listrik. Dayton 7M7V3 dengan 25,642 cfm, blade 48 in, dan motor 208-230/460V AC cocok untuk area luas. Pastikan juga tipe belt-drive sesuai untuk aplikasi darurat dan asap.

Digunakan dalam

Aplikasi umum untuk Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Produk

3G Electric memasok Dayton emergency smoke belt-drive fans with drive. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Belt-drive axial upblast fan for roof exhaust applications requiring clean air movement. Delivers 21,814 cfm with a 42-inch blade, powered by a 1 1/2 hp open drip-proof motor. Single-speed unit operates on 115/208-230V AC. Suitable for removing heat, fumes, or stale air from industrial or commercial spaces
Dayton
Belt-drive axial upblast fan for roof exhaust applications requiring clean air movement. Delivers 21,814 cfm with a 42-inch blade, powered by a 1 1/2 hp open drip-proof motor. Single-speed unit operates on 115/208-230V AC. Suitable for removing heat, fumes, or stale air from industrial or commercial spaces
Belt-drive axial upblast roof exhaust fan for clean-air applications. Removes heat, fumes, and odors from industrial and commercial facilities by exhausting air vertically upward. Features a 42-inch blade, 23,987 cfm airflow, and a 2 hp ODP motor. Operates at single speed on 115/208-230V AC power
Dayton
Belt-drive axial upblast roof exhaust fan for clean-air applications. Removes heat, fumes, and odors from industrial and commercial facilities by exhausting air vertically upward. Features a 42-inch blade, 23,987 cfm airflow, and a 2 hp ODP motor. Operates at single speed on 115/208-230V AC power
This belt-drive axial upblast roof exhaust fan features a 36-inch blade and delivers 13,858 cfm. It is powered by a single-speed, 3/4 hp ODP motor rated for 208/220/440V AC three-phase. Designed for clean air applications, it is commonly used for exhausting heat, fumes, and odors from industrial and commercial facilities
Dayton
This belt-drive axial upblast roof exhaust fan features a 36-inch blade and delivers 13,858 cfm. It is powered by a single-speed, 3/4 hp ODP motor rated for 208/220/440V AC three-phase. Designed for clean air applications, it is commonly used for exhausting heat, fumes, and odors from industrial and commercial facilities
This belt-drive axial upblast roof exhaust fan is designed for industrial clean air exhaust applications, such as removing fumes or heat from manufacturing plants and warehouses. It features a 54-inch blade, delivers 33,788 cfm, and is powered by a 2 hp ODP motor with single speed. The fan operates on 115/208-230V AC and directs exhaust upward away from the roof surface
Dayton
This belt-drive axial upblast roof exhaust fan is designed for industrial clean air exhaust applications, such as removing fumes or heat from manufacturing plants and warehouses. It features a 54-inch blade, delivers 33,788 cfm, and is powered by a 2 hp ODP motor with single speed. The fan operates on 115/208-230V AC and directs exhaust upward away from the roof surface
Belt-drive axial upblast roof exhaust fan with a 48-inch blade delivering 28,075 cfm. Single-speed motor is TEFC, 2 hp, and operates at 115/230V AC. Used for clean air exhaust in industrial and commercial settings to remove heat, fumes, or odors
Dayton
Belt-drive axial upblast roof exhaust fan with a 48-inch blade delivering 28,075 cfm. Single-speed motor is TEFC, 2 hp, and operates at 115/230V AC. Used for clean air exhaust in industrial and commercial settings to remove heat, fumes, or odors
Belt-drive axial upblast roof exhaust fan for clean-air ventilation. 36-inch blade delivers 19,212 cfm. Powered by a 2 hp ODP single-speed motor. Nameplate voltage 115/208-230V AC. Suitable for exhausting fumes, heat, and odors in industrial and commercial facilities
Dayton
Belt-drive axial upblast roof exhaust fan for clean-air ventilation. 36-inch blade delivers 19,212 cfm. Powered by a 2 hp ODP single-speed motor. Nameplate voltage 115/208-230V AC. Suitable for exhausting fumes, heat, and odors in industrial and commercial facilities

Lainnya dari Dayton

Lihat semua Dayton suku cadang
This unassembled belt-drive fan is designed for emergency smoke exhaust in horizontal industrial ventilation systems. It delivers 9,112 cfm at 0.000 in static pressure, powered by a 2 hp, 3-phase, totally enclosed fan cooled motor. The 24-inch blade and single-speed operation support smoke and heat removal during fire events. Not rated for hazardous locations
Dayton
This unassembled belt-drive fan is designed for emergency smoke exhaust in horizontal industrial ventilation systems. It delivers 9,112 cfm at 0.000 in static pressure, powered by a 2 hp, 3-phase, totally enclosed fan cooled motor. The 24-inch blade and single-speed operation support smoke and heat removal during fire events. Not rated for hazardous locations
Unassembled emergency smoke belt-drive fan with drive package. 30 in blade delivers 9,825 cfm at 0.000 in SP. Powered by a 1 hp capacitor-start motor, totally enclosed fan-cooled, single-speed, 115/208-230V AC. Vertical mounting orientation. Not rated for hazardous locations. Used for smoke exhaust in commercial or industrial buildings during fire emergencies
Dayton
Unassembled emergency smoke belt-drive fan with drive package. 30 in blade delivers 9,825 cfm at 0.000 in SP. Powered by a 1 hp capacitor-start motor, totally enclosed fan-cooled, single-speed, 115/208-230V AC. Vertical mounting orientation. Not rated for hazardous locations. Used for smoke exhaust in commercial or industrial buildings during fire emergencies
Unassembled emergency smoke belt-drive fan with drive package. 30-inch blade delivers 12,190 cfm at 0.000 in SP. 2 hp, 3-phase, totally enclosed fan cooled motor, single-speed, 208-230/460V AC. For horizontal mounting. Not rated for hazardous locations. Used for smoke and heat exhaust in fire emergencies
Dayton
Unassembled emergency smoke belt-drive fan with drive package. 30-inch blade delivers 12,190 cfm at 0.000 in SP. 2 hp, 3-phase, totally enclosed fan cooled motor, single-speed, 208-230/460V AC. For horizontal mounting. Not rated for hazardous locations. Used for smoke and heat exhaust in fire emergencies
Unassembled emergency smoke belt-drive fan with drive. Features a 30-inch blade delivering 14,040 cfm at 0.000 in SP. Powered by a 115/230V AC, 1-phase capacitor-start capacitor-run motor in a totally enclosed fan-cooled enclosure. Designed for horizontal mounting in smoke-control ventilation systems. Not rated for hazardous locations
Dayton
Unassembled emergency smoke belt-drive fan with drive. Features a 30-inch blade delivering 14,040 cfm at 0.000 in SP. Powered by a 115/230V AC, 1-phase capacitor-start capacitor-run motor in a totally enclosed fan-cooled enclosure. Designed for horizontal mounting in smoke-control ventilation systems. Not rated for hazardous locations
This unassembled emergency smoke belt-drive fan is designed for smoke exhaust in fire-emergency ventilation systems. It features a 30-inch blade delivering 12,190 cfm at 0.000 in SP, powered by a 2 hp capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. The fan operates on 115/208-230V AC, mounts horizontally, and includes a drive package. It is not rated for hazardous locations
Dayton
This unassembled emergency smoke belt-drive fan is designed for smoke exhaust in fire-emergency ventilation systems. It features a 30-inch blade delivering 12,190 cfm at 0.000 in SP, powered by a 2 hp capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. The fan operates on 115/208-230V AC, mounts horizontally, and includes a drive package. It is not rated for hazardous locations
This belt-drive upblast roof fan is designed for emergency smoke control and general industrial exhaust. It features a 48-inch blade delivering 29,373 cfm, powered by a single-speed TEFC 3 hp motor operating at 208-230/460V AC, three-phase. Suitable for removing smoke, heat, and fumes from commercial or manufacturing facilities during fire events or routine ventilation
Dayton
This belt-drive upblast roof fan is designed for emergency smoke control and general industrial exhaust. It features a 48-inch blade delivering 29,373 cfm, powered by a single-speed TEFC 3 hp motor operating at 208-230/460V AC, three-phase. Suitable for removing smoke, heat, and fumes from commercial or manufacturing facilities during fire events or routine ventilation
This belt-drive axial upblast roof fan is designed for emergency smoke exhaust and general industrial ventilation. It features a 48-inch blade, delivers 34,761 cfm, and is powered by a 5 hp TEFC motor. The single-speed unit operates on 208-230/460V AC, three-phase power
Dayton
This belt-drive axial upblast roof fan is designed for emergency smoke exhaust and general industrial ventilation. It features a 48-inch blade, delivers 34,761 cfm, and is powered by a 5 hp TEFC motor. The single-speed unit operates on 208-230/460V AC, three-phase power
Unassembled belt-drive fan for emergency smoke exhaust applications. Delivers 35,365 cfm at 0.000 in SP with a 48-inch blade. Powered by a 230V AC, single-phase, capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. Includes drive package; designed for vertical mounting. Not rated for hazardous locations
Dayton
Unassembled belt-drive fan for emergency smoke exhaust applications. Delivers 35,365 cfm at 0.000 in SP with a 48-inch blade. Powered by a 230V AC, single-phase, capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. Includes drive package; designed for vertical mounting. Not rated for hazardous locations