Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dayton Flammable Vapor Belt-Drive Fan with Drive, 1,880 cfm, 13 1/4 in Wheel - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive, 1,880 cfm, 13 1/4 in Wheel

Dayton Centrifugal Downblast Roof Exhaust Fan dengan penggerak sabuk (belt drive) adalah kipas pembuang atap yang dirancang untuk area berbahaya (flammable vapor). Model 7AF09 ini memiliki kapasitas udara buang 1.880…

SKU 3G-OTH-81331

Merek
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive, 1,880 cfm, 13 1/4 in Wheel
Kategori
Flammable Vapor Belt-Drive Fans with Drive
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dayton
Type
Includes Drive Pack, 1,880 cfm
Wheel
13 1/4 in
Assembly
Unassembled
Base Shape
Square
Drive Package
Includes Drive Package
Motor Enclosure
Totally Enclosed Nonventilated
Motor Efficiency
Standard-Efficiency Motors
Number of Speeds
1
Mounting Location
Roof
Nameplate Voltage
230/460V AC
High-Efficiency Motor
No
Hazardous Location Rating
Class I Groups C & D, Class II Groups E & F
Hazardous Location Specification
Class I Group C, Class I Group D, Class II Group E, Class II Group F, Class II Group F
Exhaust Airflow @ 0.000 in SP - Range
0 to 1,999 cfm
Exhaust Airflow @ 0.500 in SP - Range
0 to 1,999 cfm
For High-Static Pressure Applications
No

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dayton Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Dayton Centrifugal Downblast Roof Exhaust Fan dengan penggerak sabuk (belt drive) adalah kipas pembuang atap yang dirancang untuk area berbahaya (flammable vapor). Model 7AF09 ini memiliki kapasitas udara buang 1.880 cfm, dilengkapi Drive Package, roda kipas berdiameter 13 1/4 inci, dan motor Totally Enclosed Nonventilated (TENV) 230/460V AC. Kipas ini memiliki rating lokasi berbahaya Class I Groups C & D dan Class II Groups E & F, sehingga cocok untuk aplikasi industri yang memerlukan kipas pembuang atap tahan ledakan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Dayton Centrifugal Downblast Roof Exhaust Fan 7AF09 digunakan?

Kipas ini digunakan sebagai exhaust fan atap untuk membuang udara panas, uap, atau kontaminan dari area industri. Dengan rating lokasi berbahaya Class I Groups C & D dan Class II Groups E & F, kipas ini aman digunakan di lingkungan yang mengandung uap atau debu mudah terbakar.

Apa spesifikasi teknis Dayton 7AF09?

Spesifikasi teknis meliputi: kapasitas udara buang 1.880 cfm, roda kipas 13 1/4 inci, motor TENV 230/460V AC standar efisiensi, 1 kecepatan, dan termasuk Drive Package. Kipas ini tidak dirakit (unassembled) dan memiliki basis berbentuk persegi.

Di mana beli Dayton Centrifugal Downblast Roof Exhaust Fan 7AF09 di Indonesia?

Anda dapat membeli Dayton 7AF09 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda dapat menerima produk dengan mudah.

Apakah kipas Dayton 7AF09 tahan ledakan?

Ya, kipas ini memiliki rating lokasi berbahaya Class I Groups C & D (uap mudah terbakar) dan Class II Groups E & F (debu mudah terbakar). Ini berarti kipas dirancang untuk digunakan di area yang memerlukan perlindungan terhadap percikan api atau ledakan.

Bagaimana cara memilih exhaust fan atap untuk area berbahaya?

Pilih exhaust fan dengan rating lokasi berbahaya yang sesuai, seperti Class I Groups C & D untuk uap dan Class II Groups E & F untuk debu. Pastikan kapasitas udara (cfm) dan ukuran roda kipas sesuai kebutuhan ventilasi Anda. Dayton 7AF09 dengan 1.880 cfm dan roda 13 1/4 inci adalah pilihan yang tepat.

Digunakan dalam

Aplikasi umum untuk Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Produk

3G Electric memasok Dayton flammable vapor belt-drive fans with drive. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This flammable vapor belt-drive fan includes a drive package and is rated for hazardous locations Class I Groups C & D and Class II Groups E & F. It features a 30 1/2-inch wheel, delivers 9,719 cfm, and operates on 208-230V AC with a totally enclosed fan-cooled motor. The unassembled unit has a square base for roof mounting
Dayton
This flammable vapor belt-drive fan includes a drive package and is rated for hazardous locations Class I Groups C & D and Class II Groups E & F. It features a 30 1/2-inch wheel, delivers 9,719 cfm, and operates on 208-230V AC with a totally enclosed fan-cooled motor. The unassembled unit has a square base for roof mounting
This belt-drive fan is designed for roof mounting and includes a drive package. It features a 24 1/2 in wheel and delivers 4,637 cfm exhaust airflow. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. Suitable for hazardous locations rated Class I Groups C & D and Class II Groups E & F
Dayton
This belt-drive fan is designed for roof mounting and includes a drive package. It features a 24 1/2 in wheel and delivers 4,637 cfm exhaust airflow. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. Suitable for hazardous locations rated Class I Groups C & D and Class II Groups E & F
This belt-drive fan is designed for roof-mounted exhaust in hazardous locations. It includes a drive pack and features a 14 3/4 in wheel delivering 2,170 cfm. The totally enclosed nonventilated motor operates at 230/460V AC. Rated for Class I Groups C & D and Class II Groups E, F & G, it is suitable for ventilating areas with flammable vapors or combustible dusts
Dayton
This belt-drive fan is designed for roof-mounted exhaust in hazardous locations. It includes a drive pack and features a 14 3/4 in wheel delivering 2,170 cfm. The totally enclosed nonventilated motor operates at 230/460V AC. Rated for Class I Groups C & D and Class II Groups E, F & G, it is suitable for ventilating areas with flammable vapors or combustible dusts
Belt-drive roof exhaust fan with 24 1/2 in wheel delivering 4,223 cfm. Includes drive pack; unassembled. Totally enclosed nonventilated motor, single-speed, 115/208-230V AC. Rated for hazardous locations Class I Groups C & D, Class II Groups E & F
Dayton
Belt-drive roof exhaust fan with 24 1/2 in wheel delivering 4,223 cfm. Includes drive pack; unassembled. Totally enclosed nonventilated motor, single-speed, 115/208-230V AC. Rated for hazardous locations Class I Groups C & D, Class II Groups E & F
Belt-drive roof exhaust fan for hazardous locations rated Class I Groups C & D and Class II Groups E & F. Includes drive package, 30 1/2 in wheel, 8,585 cfm airflow, and totally enclosed fan-cooled motor (115/208-230V AC, single speed). Unassembled with square base; not for high-static-pressure applications
Dayton
Belt-drive roof exhaust fan for hazardous locations rated Class I Groups C & D and Class II Groups E & F. Includes drive package, 30 1/2 in wheel, 8,585 cfm airflow, and totally enclosed fan-cooled motor (115/208-230V AC, single speed). Unassembled with square base; not for high-static-pressure applications
This belt-drive centrifugal downblast roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It includes a drive package and features a 24 1/2 in wheel delivering 5,371 cfm. The unassembled fan has a square base and a totally enclosed fan cooled motor rated at 115/208-230V AC. Typical applications include ventilation of areas where flammable vapors or combustible dusts may be present
Dayton
This belt-drive centrifugal downblast roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It includes a drive package and features a 24 1/2 in wheel delivering 5,371 cfm. The unassembled fan has a square base and a totally enclosed fan cooled motor rated at 115/208-230V AC. Typical applications include ventilation of areas where flammable vapors or combustible dusts may be present

Lainnya dari Dayton

Lihat semua Dayton suku cadang
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B