Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dayton Non-Reversing IEC Contactor, 18 A, 3 Poles, 120V AC Coil, 3NO - Non-Reversing IEC Contactors
DaytonNon-Reversing IEC Contactors

Dayton Non-Reversing IEC Contactor, 18 A, 3 Poles, 120V AC Coil, 3NO

DAYTON IEC Magnetic Contactor Non-Reversing tipe 6EAV6 adalah kontaktor industri 3 kutub dengan rating arus 18 A dan koil AC 120V. Kontaktor ini dilengkapi 3 kontak NO (Normally Open) tanpa surge suppression…

SKU 3G-OTH-42801

Merek
Dayton
Item
Non-Reversing IEC Contactor, 18 A, 3 Poles, 120V AC Coil, 3NO
Kategori
Non-Reversing IEC Contactors
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dayton
Type
18 A
Poles
3
AC Coil
120V
Contacts
3NO
Integrated Surge Suppression
No

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dayton Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

DAYTON IEC Magnetic Contactor Non-Reversing tipe 6EAV6 adalah kontaktor industri 3 kutub dengan rating arus 18 A dan koil AC 120V. Kontaktor ini dilengkapi 3 kontak NO (Normally Open) tanpa surge suppression terintegrasi, dirancang untuk aplikasi switching beban listrik pada panel kontrol dan sistem otomasi pabrik. Sebagai komponen peralatan industri yang andal, produk ini cocok untuk berbagai kebutuhan kontrol motor dan peralatan pembakaran di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi DAYTON IEC Magnetic Contactor Non-Reversing 6EAV6?

DAYTON IEC Magnetic Contactor Non-Reversing 6EAV6 memiliki spesifikasi: tipe 18 A, 3 kutub, koil AC 120V, 3 kontak NO, tanpa surge suppression terintegrasi. Produk ini ideal untuk aplikasi switching beban listrik di panel kontrol industri.

Untuk apa DAYTON IEC Magnetic Contactor Non-Reversing digunakan?

Kontaktor DAYTON ini digunakan untuk mengontrol aliran listrik ke motor listrik, pemanas, atau peralatan pembakaran pada sistem otomasi pabrik. Dengan 3 kontak NO dan koil 120V AC, ia cocok untuk aplikasi switching non-reversing pada panel kontrol industri.

Di mana beli DAYTON IEC Magnetic Contactor Non-Reversing di Indonesia?

Anda dapat membeli DAYTON IEC Magnetic Contactor Non-Reversing 6EAV6 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi Anda.

Bagaimana cara memilih kontaktor IEC yang tepat untuk panel kontrol?

Pilih kontaktor berdasarkan rating arus (18 A), jumlah kutub (3), tegangan koil (120V AC), dan jumlah kontak NO (3). DAYTON 6EAV6 sesuai untuk aplikasi non-reversing dengan beban hingga 18 A. Pastikan koil sesuai dengan suplai listrik panel Anda.

Digunakan dalam

Aplikasi umum untuk Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Produk

3G Electric memasok Dayton non-reversing iec contactors. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open (NO) contacts. Rated for 9 A with a 120V AC coil. Suitable for switching electrical loads in motor control and automation systems, such as conveyors, pumps, and compressors
Dayton
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open (NO) contacts. Rated for 9 A with a 120V AC coil. Suitable for switching electrical loads in motor control and automation systems, such as conveyors, pumps, and compressors
This non-reversing IEC contactor from Dayton features 3 poles and 3 normally open (NO) contacts, rated for 12 A with a 120V AC coil. It is designed for switching electrical loads in motor control and automation systems, such as conveyors, pumps, and compressors. This model does not include integrated surge suppression
Dayton
This non-reversing IEC contactor from Dayton features 3 poles and 3 normally open (NO) contacts, rated for 12 A with a 120V AC coil. It is designed for switching electrical loads in motor control and automation systems, such as conveyors, pumps, and compressors. This model does not include integrated surge suppression
DAYTON IEC Magnetic Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 25 A, 120V AC Coil
Dayton
DAYTON IEC Magnetic Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 25 A, 120V AC Coil
DAYTON IEC Magnetic Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 18 A, 240V AC Coil
Dayton
DAYTON IEC Magnetic Contactor: Non-Reversing, 3 Poles, 3NO Contacts, 18 A, 240V AC Coil
This 3-pole IEC magnetic contactor is rated at 18 A with a 24V AC coil and three normally open (NO) contacts. It is designed for non-reversing switching of three-phase circuits in motor control and power distribution applications. The contactor does not include integrated surge suppression
Dayton
This 3-pole IEC magnetic contactor is rated at 18 A with a 24V AC coil and three normally open (NO) contacts. It is designed for non-reversing switching of three-phase circuits in motor control and power distribution applications. The contactor does not include integrated surge suppression
This three-pole non-reversing IEC contactor features three normally open (NO) contacts and a 24V AC coil. Rated for 12 A, it is suited for switching electrical loads in motor control and automation systems, such as pumps, fans, and conveyors. No integrated surge suppression
Dayton
This three-pole non-reversing IEC contactor features three normally open (NO) contacts and a 24V AC coil. Rated for 12 A, it is suited for switching electrical loads in motor control and automation systems, such as pumps, fans, and conveyors. No integrated surge suppression

Lainnya dari Dayton

Lihat semua Dayton suku cadang
This non-reversing IEC contactor features 3 poles and 3 normally open (NO) contacts, rated for 65 A with a 120V AC coil. It does not include integrated surge suppression. Typical applications include switching motor loads and other inductive loads in industrial control panels
Dayton
This non-reversing IEC contactor features 3 poles and 3 normally open (NO) contacts, rated for 65 A with a 120V AC coil. It does not include integrated surge suppression. Typical applications include switching motor loads and other inductive loads in industrial control panels
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open contacts. Rated for 50 A with a 240V AC coil. Suitable for switching three-phase motors in applications such as conveyors, pumps, and compressors
Dayton
Non-reversing IEC magnetic contactor with 3 poles and 3 normally open contacts. Rated for 50 A with a 240V AC coil. Suitable for switching three-phase motors in applications such as conveyors, pumps, and compressors
This non-reversing IEC contactor features 3 poles with 3 normally open contacts, rated for 12 A and a 240V AC coil. It is designed for switching electrical loads in industrial motor control and automation systems, such as conveyors, pumps, and fans requiring on/off control of 3-phase motors. No integrated surge suppression is included
Dayton
This non-reversing IEC contactor features 3 poles with 3 normally open contacts, rated for 12 A and a 240V AC coil. It is designed for switching electrical loads in industrial motor control and automation systems, such as conveyors, pumps, and fans requiring on/off control of 3-phase motors. No integrated surge suppression is included
This non-reversing IEC contactor from Dayton features 4 poles with 2 normally open and 2 normally closed contacts. Rated for 12 A with a 24V DC coil, it is used for switching motors, lighting, and heating circuits in industrial control systems. Integrated surge suppression is not included
Dayton
This non-reversing IEC contactor from Dayton features 4 poles with 2 normally open and 2 normally closed contacts. Rated for 12 A with a 24V DC coil, it is used for switching motors, lighting, and heating circuits in industrial control systems. Integrated surge suppression is not included
This non-reversing IEC magnetic contactor from Dayton features three poles and three normally open (NO) contacts, rated for 80 A with a 24V DC coil. It does not include integrated surge suppression. Typical applications include switching and controlling three-phase motors, lighting, and HVAC equipment in industrial and commercial systems
Dayton
This non-reversing IEC magnetic contactor from Dayton features three poles and three normally open (NO) contacts, rated for 80 A with a 24V DC coil. It does not include integrated surge suppression. Typical applications include switching and controlling three-phase motors, lighting, and HVAC equipment in industrial and commercial systems
This non-reversing IEC contactor features three poles and three normally open contacts, rated for 95 A with a 24V DC coil. It is used for switching motors, lighting, and heating loads in industrial control panels and machinery
Dayton
This non-reversing IEC contactor features three poles and three normally open contacts, rated for 95 A with a 24V DC coil. It is used for switching motors, lighting, and heating loads in industrial control panels and machinery
This 3-pole IEC contactor is rated for 32 A and features a 240V AC coil with three normally open (NO) contacts. It is designed for non-reversing motor control applications such as conveyors, pumps, and compressors. The contactor does not include integrated surge suppression
Dayton
This 3-pole IEC contactor is rated for 32 A and features a 240V AC coil with three normally open (NO) contacts. It is designed for non-reversing motor control applications such as conveyors, pumps, and compressors. The contactor does not include integrated surge suppression
This 4-pole non-reversing IEC contactor is rated for 9 A with a 24V AC coil and features 2 normally open and 2 normally closed contacts. It is used for switching electrical loads in motor control and automation systems, such as controlling pumps, fans, conveyors, and compressors. Integrated surge suppression is not included
Dayton
This 4-pole non-reversing IEC contactor is rated for 9 A with a 24V AC coil and features 2 normally open and 2 normally closed contacts. It is used for switching electrical loads in motor control and automation systems, such as controlling pumps, fans, conveyors, and compressors. Integrated surge suppression is not included