Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dayton Flammable Vapor Belt-Drive Fan with Drive - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive

DAYTON Tubeaxial Fan untuk uap mudah terbakar adalah kipas industri belt-drive yang dirancang untuk area berbahaya. Dengan spesifikasi Kelas I Grup C, kipas ini memiliki aliran udara 4.039 cfm pada 0,000 in SP…

SKU 3G-OTH-77650

Merek
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive
Kategori
Flammable Vapor Belt-Drive Fans with Drive
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dayton
Type
4,039 cfm @ 0.000 in SP
AC
115/230V
Blade
18 in
Phase
1
Assembly
Unassembled
Motor Type
Capacitor-Start
Motor Enclosure
Totally Enclosed Fan Cooled
Number of Speeds
1
Nameplate Voltage
115/230V AC
Mounting Orientation
Vertical
Includes Drive Package
Yes
Airflow @ 0.000 in SP - Range
0 to 9,999 cfm
Hazardous Location Specification
Class I Group C
Spark Resistant Construction Type
B

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dayton Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

DAYTON Tubeaxial Fan untuk uap mudah terbakar adalah kipas industri belt-drive yang dirancang untuk area berbahaya. Dengan spesifikasi Kelas I Grup C, kipas ini memiliki aliran udara 4.039 cfm pada 0,000 in SP, diameter blade 18 inci, dan motor capacitor-start 115/230V AC 1 fase dengan enclosure TEFC. Konstruksi tahan percikan api Tipe B memastikan keamanan di lingkungan yang memerlukan penanganan uap mudah terbakar. Cari kipas tahan ledakan untuk industri? DAYTON 7F952 adalah pilihan yang tepat.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa DAYTON Tubeaxial Fan 7F952 digunakan?

Kipas DAYTON 7F952 digunakan untuk ventilasi di area berbahaya yang mengandung uap mudah terbakar, sesuai spesifikasi Kelas I Grup C. Dengan aliran udara 4.039 cfm dan konstruksi tahan percikan api Tipe B, kipas ini cocok untuk aplikasi industri seperti pabrik kimia, kilang minyak, atau fasilitas pengolahan yang memerlukan sirkulasi udara aman.

Apa spesifikasi motor DAYTON Tubeaxial Fan 7F952?

Motor DAYTON 7F952 adalah capacitor-start 1 fase dengan tegangan 115/230V AC, enclosure Totally Enclosed Fan Cooled (TEFC), dan 1 kecepatan. Motor ini dirancang untuk pemasangan vertikal dan sudah termasuk drive package. Daya dorongnya mencapai 4.039 cfm pada 0,000 in SP dengan blade 18 inci.

Di mana beli DAYTON Tubeaxial Fan 7F952 di Indonesia?

Anda dapat membeli DAYTON Tubeaxial Fan 7F952 melalui 3G Electric, distributor resmi yang memasok peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk pengiriman langsung ke lokasi Anda. Hubungi kami untuk minta penawaran dan informasi ketersediaan produk.

Apa perbedaan konstruksi tahan percikan api Tipe B pada kipas DAYTON?

Konstruksi tahan percikan api Tipe B pada DAYTON 7F952 dirancang untuk mengurangi risiko percikan api yang dapat menyulut uap mudah terbakar. Ini termasuk penggunaan material non-ferrous pada komponen kritis. Kipas ini memenuhi spesifikasi Kelas I Grup C untuk lokasi berbahaya, memastikan operasi aman di lingkungan dengan uap mudah terbakar.

Bagaimana cara memilih kipas tubeaxial untuk area berbahaya?

Pilih kipas tubeaxial seperti DAYTON 7F952 dengan spesifikasi Kelas I Grup C untuk uap mudah terbakar. Perhatikan aliran udara (4.039 cfm), diameter blade (18 inci), dan konstruksi tahan percikan api Tipe B. Pastikan motor TEFC dan tegangan sesuai (115/230V AC 1 fase). DAYTON 7F952 adalah pilihan andal untuk aplikasi ventilasi industri berbahaya.

Digunakan dalam

Aplikasi umum untuk Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Produk

3G Electric memasok Dayton flammable vapor belt-drive fans with drive. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Unassembled belt-drive fan with 18-inch blade delivering 4,671 cfm at 0.000 in SP. Operates on 115/230V AC, single phase, with a capacitor-start motor in a totally enclosed fan-cooled enclosure. Spark-resistant construction type B for hazardous locations Class I Groups C and D. Includes drive package; vertical mounting orientation
Dayton
Unassembled belt-drive fan with 18-inch blade delivering 4,671 cfm at 0.000 in SP. Operates on 115/230V AC, single phase, with a capacitor-start motor in a totally enclosed fan-cooled enclosure. Spark-resistant construction type B for hazardous locations Class I Groups C and D. Includes drive package; vertical mounting orientation
This belt-drive fan is designed for horizontal mounting in hazardous locations classified as Class I Groups C and D. It features spark-resistant construction type B, a capacitor-start motor with a totally enclosed fan-cooled enclosure, and delivers 3,494 cfm at 0.000 in SP. The unassembled unit includes a drive package and operates on 115/230V AC single-phase power
Dayton
This belt-drive fan is designed for horizontal mounting in hazardous locations classified as Class I Groups C and D. It features spark-resistant construction type B, a capacitor-start motor with a totally enclosed fan-cooled enclosure, and delivers 3,494 cfm at 0.000 in SP. The unassembled unit includes a drive package and operates on 115/230V AC single-phase power
Belt-drive tubeaxial fan with Type B spark-resistant construction for Class I Group C hazardous locations. Unassembled unit includes drive package; 18 in blade delivers 3,230 cfm at 0.000 in SP. Capacitor-start motor, 115/230V AC, single-phase, totally enclosed fan-cooled. Vertical mounting orientation
Dayton
Belt-drive tubeaxial fan with Type B spark-resistant construction for Class I Group C hazardous locations. Unassembled unit includes drive package; 18 in blade delivers 3,230 cfm at 0.000 in SP. Capacitor-start motor, 115/230V AC, single-phase, totally enclosed fan-cooled. Vertical mounting orientation
This unassembled belt-drive fan is designed for horizontal mounting in hazardous locations classified as Class I Group C. It features a 12 in blade, delivers 2,432 cfm at 0.000 in SP, and operates on 115/230V AC single phase. The capacitor-start motor has a totally enclosed fan cooled enclosure, and the fan includes a drive package with spark resistant construction type B
Dayton
This unassembled belt-drive fan is designed for horizontal mounting in hazardous locations classified as Class I Group C. It features a 12 in blade, delivers 2,432 cfm at 0.000 in SP, and operates on 115/230V AC single phase. The capacitor-start motor has a totally enclosed fan cooled enclosure, and the fan includes a drive package with spark resistant construction type B
This belt-drive fan is designed for hazardous locations where flammable vapors may be present, featuring Type B spark-resistant construction and Class I Group C compliance. It delivers 3365 cfm at 0.000 in SP with a 16-inch blade, powered by a 115/230V AC single-phase capacitor-start motor. The unassembled unit includes a drive package and is intended for horizontal mounting
Dayton
This belt-drive fan is designed for hazardous locations where flammable vapors may be present, featuring Type B spark-resistant construction and Class I Group C compliance. It delivers 3365 cfm at 0.000 in SP with a 16-inch blade, powered by a 115/230V AC single-phase capacitor-start motor. The unassembled unit includes a drive package and is intended for horizontal mounting
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features a 16-inch blade, delivers 3859 cfm at 0.000 in SP, and operates on 115/230V AC single-phase power with a capacitor-start motor. The unit has Type B spark-resistant construction, is unassembled, includes a drive package, and is intended for horizontal mounting
Dayton
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features a 16-inch blade, delivers 3859 cfm at 0.000 in SP, and operates on 115/230V AC single-phase power with a capacitor-start motor. The unit has Type B spark-resistant construction, is unassembled, includes a drive package, and is intended for horizontal mounting

Lainnya dari Dayton

Lihat semua Dayton suku cadang
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B