Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Dayton Flammable Vapor Belt-Drive Fan with Drive - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive

DAYTON Tubeaxial Fan untuk uap mudah terbakar adalah kipas industri belt-drive yang dirancang untuk area berbahaya. Dengan bilah berdiameter 34 inci, kipas ini mampu menghasilkan aliran udara 14.430 cfm pada 0.000 in…

SKU 3G-OTH-78373

Merek
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive
Kategori
Flammable Vapor Belt-Drive Fans with Drive
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dayton
Type
14,430 cfm @ 0.000 in SP, 2 hp
AC
208-230/460V
Blade
34 in
Assembly
Unassembled
Motor Type
3-Phase
Motor Enclosure
Totally Enclosed Fan Cooled
Number of Speeds
1
Nameplate Voltage
208-230/460V AC
Mounting Orientation
Horizontal
Includes Drive Package
Yes
Airflow @ 0.000 in SP - Range
10,000 to 19,999 cfm
Hazardous Location Specification
Class I Group C
Spark Resistant Construction Type
B

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dayton Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

DAYTON Tubeaxial Fan untuk uap mudah terbakar adalah kipas industri belt-drive yang dirancang untuk area berbahaya. Dengan bilah berdiameter 34 inci, kipas ini mampu menghasilkan aliran udara 14.430 cfm pada 0.000 in SP dengan daya 2 hp. Motor 3-phase 208-230/460V AC dengan enclosure TEFC memastikan keandalan di lingkungan yang memerlukan konstruksi tahan percikan api Tipe B dan spesifikasi lokasi berbahaya Kelas I Grup C. Produk ini dijual dalam bentuk belum dirakit dan sudah termasuk paket penggerak (drive package).

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa DAYTON Tubeaxial Fan 7F854 digunakan?

Kipas DAYTON Tubeaxial 7F854 dirancang untuk ventilasi di area yang mengandung uap mudah terbakar, sesuai spesifikasi lokasi berbahaya Kelas I Grup C. Konstruksi tahan percikan api Tipe B membuatnya cocok untuk lingkungan industri seperti pabrik kimia, kilang minyak, atau fasilitas pengolahan yang memerlukan sirkulasi udara aman.

Apa spesifikasi DAYTON Tubeaxial Fan 7F854?

DAYTON Tubeaxial Fan 7F854 memiliki bilah 34 inci, aliran udara 14.430 cfm pada 0.000 in SP, daya 2 hp, motor 3-phase 208-230/460V AC, enclosure TEFC, satu kecepatan, orientasi horizontal, dan dijual dalam bentuk belum dirakit. Produk ini termasuk paket penggerak (drive package) dan memenuhi spesifikasi lokasi berbahaya Kelas I Grup C dengan konstruksi tahan percikan api Tipe B.

Di mana beli DAYTON Tubeaxial Fan 7F854 di Indonesia?

Anda dapat membeli DAYTON Tubeaxial Fan 7F854 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga Anda tidak perlu repot mengurus impor. Hubungi kami untuk minta penawaran dan informasi ketersediaan produk.

Bagaimana cara memilih DAYTON Tubeaxial Fan untuk area berbahaya?

Pilih DAYTON Tubeaxial Fan berdasarkan kebutuhan aliran udara (cfm), tekanan statis, dan klasifikasi area berbahaya. Model 7F854 dengan spesifikasi Kelas I Grup C dan konstruksi tahan percikan api Tipe B cocok untuk uap mudah terbakar. Pastikan motor 3-phase 208-230/460V AC sesuai dengan suplai listrik Anda. Konsultasikan dengan teknisi 3G Electric untuk pemilihan yang tepat.

Digunakan dalam

Aplikasi umum untuk Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Produk

3G Electric memasok Dayton flammable vapor belt-drive fans with drive. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 16,560 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase totally enclosed fan-cooled motor. Rated Class I Group C with Spark Resistant Construction Type B, it includes a drive package and is intended for vertical mounting in industrial ventilation systems
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 16,560 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase totally enclosed fan-cooled motor. Rated Class I Group C with Spark Resistant Construction Type B, it includes a drive package and is intended for vertical mounting in industrial ventilation systems
This unassembled belt-drive fan is designed for hazardous locations with flammable vapors. It features a 30-inch blade, delivers 10,955 cfm at 0.000 in SP, and is powered by a 3-phase, 208-230/460V AC totally enclosed fan-cooled motor. Type B spark-resistant construction and Class I Group C rating reduce ignition risk. Includes drive package; mounts vertically
Dayton
This unassembled belt-drive fan is designed for hazardous locations with flammable vapors. It features a 30-inch blade, delivers 10,955 cfm at 0.000 in SP, and is powered by a 3-phase, 208-230/460V AC totally enclosed fan-cooled motor. Type B spark-resistant construction and Class I Group C rating reduce ignition risk. Includes drive package; mounts vertically
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features Type B spark-resistant construction and is rated for Class I Group C environments. The unassembled unit includes a drive package, mounts vertically, and delivers 12,190 cfm at 0.000 in SP with a 30-inch blade and a 2 hp, 3-phase, TEFC motor
Dayton
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features Type B spark-resistant construction and is rated for Class I Group C environments. The unassembled unit includes a drive package, mounts vertically, and delivers 12,190 cfm at 0.000 in SP with a 30-inch blade and a 2 hp, 3-phase, TEFC motor
This unassembled belt-drive fan is designed for horizontal mounting and features a 30-inch blade, delivering 14,040 cfm at 0.000 in static pressure. It operates on 230/460V AC, 3-phase power with a totally enclosed fan-cooled motor. Suitable for hazardous locations classified as Class I Group C, with spark-resistant construction Type B, it is used for ventilating areas where flammable vapors may be present
Dayton
This unassembled belt-drive fan is designed for horizontal mounting and features a 30-inch blade, delivering 14,040 cfm at 0.000 in static pressure. It operates on 230/460V AC, 3-phase power with a totally enclosed fan-cooled motor. Suitable for hazardous locations classified as Class I Group C, with spark-resistant construction Type B, it is used for ventilating areas where flammable vapors may be present
This belt-drive fan is designed for flammable vapor applications in hazardous locations classified as Class I Group C. It features Type B spark-resistant construction and a totally enclosed fan-cooled motor. The unassembled unit delivers 16,495 cfm at 0.000 in SP, operates on 230/460V AC three-phase power, and includes a drive package for horizontal mounting
Dayton
This belt-drive fan is designed for flammable vapor applications in hazardous locations classified as Class I Group C. It features Type B spark-resistant construction and a totally enclosed fan-cooled motor. The unassembled unit delivers 16,495 cfm at 0.000 in SP, operates on 230/460V AC three-phase power, and includes a drive package for horizontal mounting
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features a 42-inch blade, delivers 21,465 cfm at 0.000 in SP, and operates on 230/460V AC, 3-phase power. The unit has Type B spark-resistant construction and is rated for Class I Group C hazardous locations. It includes a drive package, mounts horizontally, and is supplied unassembled with a TEFC motor
Dayton
This belt-drive fan is designed for hazardous locations where flammable vapors may be present. It features a 42-inch blade, delivers 21,465 cfm at 0.000 in SP, and operates on 230/460V AC, 3-phase power. The unit has Type B spark-resistant construction and is rated for Class I Group C hazardous locations. It includes a drive package, mounts horizontally, and is supplied unassembled with a TEFC motor

Lainnya dari Dayton

Lihat semua Dayton suku cadang
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B