Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Gambar tidak tersedia
DonganGeneral purpose transformer

Dongan 73-62150SH, three-phase general purpose transformer, 150.0 kVA

Dongan 3G-OTH-03691 adalah transformator tiga fase (three-phase) seri Three Phase General Purpose Vanguard DOE2016 dengan rating daya 150.0 kVA. Transformator ini dirancang untuk aplikasi industri umum dengan…

SKU 3G-OTH-03691

Juga terdaftar sebagai: 7362150SH · 73 62150SH

Merek
Dongan
Item
73-62150SH, three-phase general purpose transformer, 150.0 kVA
Part Number
73-62150SH
Kategori
General purpose transformer
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dongan
Series
Three Phase General Purpose Vanguard DOE2016
Phase
three-phase
Rating
150.0 kVA
Weight
1255 lb
Frequency
60 Hz
Primary voltage
480 V
Secondary voltage
240 V
Dimensions HxWxD (in)
41.00 x 34.25 x 26.75

Konten Lembar Data

[{"filename":"Dongan-General-Catalog.pdf","text":"Your source for standard and custom transformers\n\n\n Engineered solutions for\n power and the environment\n\f\f Table of Contents\n\n\n\n Single Phase..................................................................................................................... 4\n General Purpose........................................................................................................... 5\n Diagrams....................................................................................................................... 12\n Series ES‑11 CE Marked.............................................................................................. 15\n Series 33 ‑ Control........................................................................................................ 17\n Series HL ‑ Hazardous Location................................................................................... 18\n Class 2 Transformers.................................................................................................... 19\n Outline........................................................................................................................... 21\n\n Three Phase...................................................................................................................... 22\n General Purpose Vanguard DOE2016......................................................................... 23\n 76 Series Encapsulated ............................................................................................... 27\n Diagrams....................................................................................................................... 28\n Series ES‑31 CE Marked.............................................................................................. 30\n Motor Drive Isolation..................................................................................................... 31\n K‑Factor & Low Temperature. ...................................................................................... 33\n Specialty Transformers................................................................................................. 34\n Outlines......................................................................................................................... 35\n\n Buck ‑ Boost...................................................................................................................... 36\n\n Industrial Control Transformers........................................................................................ 50\n Century Series. ............................................................................................................. 51\n Series ES‑10 CE Marked.............................................................................................. 59\n Series HC...................................................................................................................... 61\n Series 50....................................................................................................................... 65\n Series AP12 & FP12. .................................................................................................... 72\n\n LTG Disconnects. ............................................................................................................. 74\n\n General Information.......................................................................................................... 85\n\n Corporate History. ............................................................................................................ 88\n\n Alphanumeric Page Reference......................................................................................... 89\n\n\n\n\n1.800.428.2626 • www.dongan.com 1\n\f THE VANGUARD SERIES Energy\n Efficient Transformers that meet\n DOE 2016 Efficiency standards\n\n The Department of Energy (DOE) has mandated improved\n energy efficiency guidelines for three phase transformers\n that went into effect on January 1, 2016.\n\n The original Energy Policy and Conservation Act (EPACT)\n was passed in 2005 and put into effect in 2007, it establish‑\n ing energy conservation standards for various consumer,\n commercial and industrial products including certain types\n of General Purpose dry-type distribution transformers.\n The Act promotes transformer designs featuring reduced\n conductor and core losses that will produce considerable\n energy savings from the installation date and continuing\n over the life of the product.\n\n The new DOE requirement affects 3 phase transformers\n only as single phase still remain under the 2005 act. This\n new ruling not only will save users money in the annual en‑\n ergy costs, it will also help to conserve energy and help the\n environment in the long term. In fact, the DOE states that\n the new efficiency levels are expected to reduce energy\n losses in the range of 15-18% on average on low voltage\n transformers over the previous TP1 designs.\n\n Cost Savings? Yes The DOE states that the 10 CFR Part\n 431.192, also known as DOE 2016 will save about $12.9\n billion in total costs to the consumers. The new distribution\n transformer standards will also save 3.63 quadrillion BTU’s\n of energy for equipment sold over the 30-year period of\n 2016 to 2045.\n\n The new amendments to the existing efficiency standards\n would further decrease electrical losses by about 8 percent\n for liquid-immersed transformers, 13 percent for medium-\n voltage dry-type transformers, and 18 percent for low-volt‑\n age dry-type transformers. In addition, about 264.7 million\n metric tons of carbon dioxide emissions will be avoided,\n equivalent to the annual greenhouse gas emissions of\n about 51.75 million automobiles.\n\n The impact of the legislation places design compliance on\n distribution transformer manufacturers. EPACT requires all\n transformers defined in the Act, manufactured subsequent\n\nSaving Energy to January 1, 2016, to be compliant with the minimum TP-1\n efficiency standards.\n\n\n\n\n2 Dongan® Electric Manufacturing Company\n\fDistribution transformers included by definition in DOE Features\n2016 are those meeting the following criteria: • \u0007Meets NEMA DOE 2016 energy efficiency\n• Operational frequency of 60 Hz. standards\n• Input voltage of 34.5 kV (34,500 Volts) or less • Aluminum or copper windings\n• Output voltage of 600 volts or less • High quality, electrical grade core steel\n•\t\u0007Liquid immersed capacity of 10 to 2,500 kVA three • \u000741 & 73 Series have a 220°C Insulation system\n phase and 10 to 833 single phase with a 150°C temperature rise\n•\t\u0007Dry-type capacity of 15 to 2,500 kVA three phase and • \u000742 & 74 Series are copper wound and have a\n 15 to 833 kVA single phase 220°C Insulation system with a 150°C temperature\n rise\nLow Voltage Dry-type Distribution: • 60 Hz\n1PH 15-333 kVA; • Wound with electrostatic shields as standard\n3PH 15-1000 kVA, ≤10kV BIL • \u0007Standard enclosures meet NEMA 3R indoor\n outdoor requirements without the purchase of\nDOE 2016 also provides exclusions for the following additional rainshields\ntypes of transformers: • Available wall mount brackets\n• Uninterruptible power supplies • Non-standard designs available\n•\t\u0007Transformers with multiple voltage taps, the \t\t • Furnished with vibration dampening pads\n highest of which equals at least \t\t\t\t\n 20% more than the lowest tap. Options\n• Special-impedance transformers • \u0007Virtually any voltage combination up to 600 volts\n• Sealed transformers may be ordered as TP-1 Compliant.\n• Non-ventilated transformers • Core and Coil Designs\n• Testing transformers • \u0007Lower temperature rises of 80°C and 115°C are\n• Grounding transformers available\n• Drive isolation transformers • 10 Year Warranty\n (Currently not excluded in Canada)\n• Autotransformers Minimum efficiency ratings are shown in the\n• Rectifier transformers chart below.\n• Regulating transformers Most installations will be covered by units displayed\n• Welding transformers\n in this catalog.\n• Machine tool control\n Please…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dongan Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Dongan 3G-OTH-03691 adalah transformator tiga fase (three-phase) seri Three Phase General Purpose Vanguard DOE2016 dengan rating daya 150.0 kVA. Transformator ini dirancang untuk aplikasi industri umum dengan frekuensi 60 Hz, tegangan primer 480 V, dan tegangan sekunder 240 V. Dengan bobot 1255 lb dan dimensi 41.00 x 34.25 x 26.75 inci, produk ini cocok untuk kebutuhan distribusi daya di pabrik dan fasilitas industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi transformator Dongan 73-62150SH?

Dongan 73-62150SH adalah transformator tiga fase dengan rating 150.0 kVA, frekuensi 60 Hz, tegangan primer 480 V, dan tegangan sekunder 240 V. Beratnya 1255 lb dengan dimensi 41.00 x 34.25 x 26.75 inci. Produk ini termasuk dalam seri Three Phase General Purpose Vanguard DOE2016.

Untuk apa transformator Dongan 73-62150SH digunakan?

Transformator Dongan 73-62150SH digunakan sebagai transformator tiga fase untuk aplikasi industri umum, seperti distribusi daya di pabrik, ketel uap, atau peralatan pembakaran. Dengan rating 150.0 kVA dan tegangan 480 V ke 240 V, produk ini cocok untuk menurunkan tegangan pada sistem kelistrikan industri.

Di mana beli transformator Dongan 73-62150SH di Indonesia?

Anda dapat membeli transformator Dongan 73-62150SH melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda dengan aman.

Bagaimana cara memilih transformator tiga fase yang tepat?

Pilih transformator tiga fase seperti Dongan 73-62150SH berdasarkan rating daya (150.0 kVA), tegangan primer (480 V), tegangan sekunder (240 V), dan frekuensi (60 Hz). Pastikan spesifikasi sesuai dengan kebutuhan beban listrik di fasilitas Anda untuk menghindari kelebihan beban.

Digunakan dalam

Aplikasi umum untuk Dongan
Industrial machine tools — Dongan HC-2000-41 control transformer for stable voltage to solenoids and relays
HVAC control panels — Dongan HC-1000-44 transformer for isolated power to thermostats and actuators
Motor control centers — Dongan HC-1500-4100 transformer for magnetic switch and relay circuits
Packaging machinery — Dongan HC-0750-4100 transformer for PLC and sensor power supply
Conveyor systems — Dongan HC-0500-4100 transformer for control voltage to motor starters
Not sure this is the right part? Photo-identify it

Dongan Produk

3G Electric memasok Dongan general purpose transformer. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dongan
Dongan
Dongan 73-63150SH, three-phase general purpose transformer, 150.0 kVA, 480 V primary / 208 V secondary, 60 Hz
Dongan
Dongan
Dongan 73-6215SH, three-phase general purpose transformer, 15.0 kVA, 480 V primary / 240 V secondary, 60 Hz
Dongan
Dongan
Dongan 73-150-2698SH, three-phase general purpose transformer, 150 kVA, 480 V primary / 60 V secondary
Dongan
Dongan
Dongan 73-6245SH, three-phase general purpose transformer, 45.0 kVA, 480 V primary / 240 V secondary, 60 Hz
Dongan
Dongan
Dongan 73-62112SH, three-phase general purpose transformer, 112.5 kVA, 480 V primary / 240 V secondary, 60 Hz
Dongan
Dongan
Dongan 73-6275SH, three-phase general purpose transformer, 75.0 kVA, 480 V primary / 240 V secondary, 60 Hz

Lainnya dari Dongan

Lihat semua Dongan suku cadang
Dongan
Dongan
Dongan 76-6-3723SH, three-phase general purpose transformer, 6 kVA
Dongan
Dongan
Dongan 85-5025SH, single-phase general purpose transformer, 0.500 kVA, 600 V primary / 120 / 240 V secondary
Dongan
Dongan
Dongan 73-15-3934SH, three-phase general purpose transformer, 15 kVA
Dongan
Dongan
Dongan 85-6030SH, single-phase general purpose transformer, 0.750 kVA, 120 / 240 V primary / 120 / 240 V secondary
Dongan
Dongan
Dongan 61-1460SH, single-phase general purpose transformer, 7.5 kVA, 240 X 480 V primary / 120 / 240 V secondary
Dongan
Dongan
Dongan 35-4010, single-phase general purpose transformer, 0.100 kVA, 277 V primary / 120 / 240 V secondary
Dongan
Dongan
Dongan 85-8055SH, single-phase general purpose transformer, 5 kVA, 277/480 V primary / 208/277 V secondary
Dongan
Dongan
Dongan 76-0203SH, three-phase general purpose transformer, 3.0 kVA, 480 V primary / 240 V secondary, 60 Hz