We ship to Indonesia — door-to-door, customs and logistics handled by 3G Electric

Image not available
DonganControl transformer

Dongan IC-1000-109, single-phase control transformer, 1000 VA

Dongan 3G-OTH-04155 adalah transformator kontrol satu fase (single-phase) dari seri Century Series Control dengan rating 1000 VA. Transformator ini dirancang untuk aplikasi kontrol pada peralatan industri seperti…

SKU 3G-OTH-04155

Also listed as: IC1000109 · IC 1000 109

Brand
Dongan
Item
IC-1000-109, single-phase control transformer, 1000 VA
Category
Control transformer
Available to Order
Ready stock & customs handled
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Ships to: Jakarta, Surabaya, Bandung, Medan, Batam
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Indonesia

Phone
+65 8878 8355

Technical Specifications

Dongan
Series
Century Series Control
Phase
single-phase
Rating
1000 VA
Weight
28.4 lb

Datasheet Content

[{"filename":"Dongan-General-Catalog.pdf","text":"Your source for standard and custom transformers\n\n\n Engineered solutions for\n power and the environment\n\f\f Table of Contents\n\n\n\n Single Phase..................................................................................................................... 4\n General Purpose........................................................................................................... 5\n Diagrams....................................................................................................................... 12\n Series ES‑11 CE Marked.............................................................................................. 15\n Series 33 ‑ Control........................................................................................................ 17\n Series HL ‑ Hazardous Location................................................................................... 18\n Class 2 Transformers.................................................................................................... 19\n Outline........................................................................................................................... 21\n\n Three Phase...................................................................................................................... 22\n General Purpose Vanguard DOE2016......................................................................... 23\n 76 Series Encapsulated ............................................................................................... 27\n Diagrams....................................................................................................................... 28\n Series ES‑31 CE Marked.............................................................................................. 30\n Motor Drive Isolation..................................................................................................... 31\n K‑Factor & Low Temperature. ...................................................................................... 33\n Specialty Transformers................................................................................................. 34\n Outlines......................................................................................................................... 35\n\n Buck ‑ Boost...................................................................................................................... 36\n\n Industrial Control Transformers........................................................................................ 50\n Century Series. ............................................................................................................. 51\n Series ES‑10 CE Marked.............................................................................................. 59\n Series HC...................................................................................................................... 61\n Series 50....................................................................................................................... 65\n Series AP12 & FP12. .................................................................................................... 72\n\n LTG Disconnects. ............................................................................................................. 74\n\n General Information.......................................................................................................... 85\n\n Corporate History. ............................................................................................................ 88\n\n Alphanumeric Page Reference......................................................................................... 89\n\n\n\n\n1.800.428.2626 • www.dongan.com 1\n\f THE VANGUARD SERIES Energy\n Efficient Transformers that meet\n DOE 2016 Efficiency standards\n\n The Department of Energy (DOE) has mandated improved\n energy efficiency guidelines for three phase transformers\n that went into effect on January 1, 2016.\n\n The original Energy Policy and Conservation Act (EPACT)\n was passed in 2005 and put into effect in 2007, it establish‑\n ing energy conservation standards for various consumer,\n commercial and industrial products including certain types\n of General Purpose dry-type distribution transformers.\n The Act promotes transformer designs featuring reduced\n conductor and core losses that will produce considerable\n energy savings from the installation date and continuing\n over the life of the product.\n\n The new DOE requirement affects 3 phase transformers\n only as single phase still remain under the 2005 act. This\n new ruling not only will save users money in the annual en‑\n ergy costs, it will also help to conserve energy and help the\n environment in the long term. In fact, the DOE states that\n the new efficiency levels are expected to reduce energy\n losses in the range of 15-18% on average on low voltage\n transformers over the previous TP1 designs.\n\n Cost Savings? Yes The DOE states that the 10 CFR Part\n 431.192, also known as DOE 2016 will save about $12.9\n billion in total costs to the consumers. The new distribution\n transformer standards will also save 3.63 quadrillion BTU’s\n of energy for equipment sold over the 30-year period of\n 2016 to 2045.\n\n The new amendments to the existing efficiency standards\n would further decrease electrical losses by about 8 percent\n for liquid-immersed transformers, 13 percent for medium-\n voltage dry-type transformers, and 18 percent for low-volt‑\n age dry-type transformers. In addition, about 264.7 million\n metric tons of carbon dioxide emissions will be avoided,\n equivalent to the annual greenhouse gas emissions of\n about 51.75 million automobiles.\n\n The impact of the legislation places design compliance on\n distribution transformer manufacturers. EPACT requires all\n transformers defined in the Act, manufactured subsequent\n\nSaving Energy to January 1, 2016, to be compliant with the minimum TP-1\n efficiency standards.\n\n\n\n\n2 Dongan® Electric Manufacturing Company\n\fDistribution transformers included by definition in DOE Features\n2016 are those meeting the following criteria: • \u0007Meets NEMA DOE 2016 energy efficiency\n• Operational frequency of 60 Hz. standards\n• Input voltage of 34.5 kV (34,500 Volts) or less • Aluminum or copper windings\n• Output voltage of 600 volts or less • High quality, electrical grade core steel\n•\t\u0007Liquid immersed capacity of 10 to 2,500 kVA three • \u000741 & 73 Series have a 220°C Insulation system\n phase and 10 to 833 single phase with a 150°C temperature rise\n•\t\u0007Dry-type capacity of 15 to 2,500 kVA three phase and • \u000742 & 74 Series are copper wound and have a\n 15 to 833 kVA single phase 220°C Insulation system with a 150°C temperature\n rise\nLow Voltage Dry-type Distribution: • 60 Hz\n1PH 15-333 kVA; • Wound with electrostatic shields as standard\n3PH 15-1000 kVA, ≤10kV BIL • \u0007Standard enclosures meet NEMA 3R indoor\n outdoor requirements without the purchase of\nDOE 2016 also provides exclusions for the following additional rainshields\ntypes of transformers: • Available wall mount brackets\n• Uninterruptible power supplies • Non-standard designs available\n•\t\u0007Transformers with multiple voltage taps, the \t\t • Furnished with vibration dampening pads\n highest of which equals at least \t\t\t\t\n 20% more than the lowest tap. Options\n• Special-impedance transformers • \u0007Virtually any voltage combination up to 600 volts\n• Sealed transformers may be ordered as TP-1 Compliant.\n• Non-ventilated transformers • Core and Coil Designs\n• Testing transformers • \u0007Lower temperature rises of 80°C and 115°C are\n• Grounding transformers available\n• Drive isolation transformers • 10 Year Warranty\n (Currently not excluded in Canada)\n• Autotransformers Minimum efficiency ratings are shown in the\n• Rectifier transformers chart below.\n• Regulating transformers Most installations will be covered by units displayed\n• Welding transformers\n in this catalog.\n• Machine tool control\n Please…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dongan Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dongan 3G-OTH-04155 adalah transformator kontrol satu fase (single-phase) dari seri Century Series Control dengan rating 1000 VA. Transformator ini dirancang untuk aplikasi kontrol pada peralatan industri seperti panel distribusi, sistem otomasi, dan pengontrol suhu (temperature controller). Dengan bobot 28,4 lb, produk ini menawarkan keandalan tinggi untuk kebutuhan daya kontrol di lingkungan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Frequently Asked Questions

Apa spesifikasi transformator kontrol Dongan IC-1000-109?

Dongan IC-1000-109 adalah transformator kontrol satu fase (single-phase) dengan rating 1000 VA dari seri Century Series Control. Berat produk ini adalah 28,4 lb. Spesifikasi ini menjadikannya cocok untuk aplikasi kontrol industri yang membutuhkan daya stabil.

Untuk apa transformator kontrol Dongan IC-1000-109 digunakan?

Transformator kontrol Dongan IC-1000-109 digunakan untuk menyediakan daya listrik yang stabil pada sistem kontrol industri, seperti panel kontrol, PLC, dan perangkat otomasi. Rating 1000 VA dan desain satu fasa membuatnya ideal untuk aplikasi yang memerlukan tegangan rendah dan arus terkontrol.

Di mana beli Dongan IC-1000-109 di Indonesia?

Anda dapat membeli Dongan IC-1000-109 melalui 3G Electric, distributor resmi yang melayani pengiriman ke seluruh Indonesia. Kami menangani logistik dan bea cukai sehingga produk sampai ke lokasi Anda dengan aman. Hubungi tim kami untuk minta penawaran.

Bagaimana cara memilih transformator kontrol yang tepat untuk aplikasi industri?

Pilih transformator kontrol berdasarkan rating daya (VA), fase (single-phase atau three-phase), dan tegangan primer/sekunder yang sesuai dengan kebutuhan sistem Anda. Dongan IC-1000-109 dengan rating 1000 VA dan desain satu fasa cocok untuk aplikasi kontrol umum. Pastikan juga mempertimbangkan berat dan dimensi untuk pemasangan.

Used in

Common applications for Dongan
Industrial machine tools — Dongan HC-2000-41 control transformer for stable voltage to solenoids and relays
HVAC control panels — Dongan HC-1000-44 transformer for isolated power to thermostats and actuators
Motor control centers — Dongan HC-1500-4100 transformer for magnetic switch and relay circuits
Packaging machinery — Dongan HC-0750-4100 transformer for PLC and sensor power supply
Conveyor systems — Dongan HC-0500-4100 transformer for control voltage to motor starters

Dongan Products

3G Electric supplies Dongan control transformer. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dongan
Dongan
Dongan IC-1000-107, single-phase control transformer, 1000 VA
Dongan
Dongan
Dongan IC-1000-102, single-phase control transformer, 1000 VA
Dongan
Dongan
Dongan IC-1000-129, single-phase control transformer, 1000 VA
Dongan
Dongan
Dongan IC-1000-123, single-phase control transformer, 1000 VA
Dongan
Dongan
Dongan IC-1000-103, single-phase control transformer, 1000 VA
Dongan
Dongan
Dongan IC-1000-122, single-phase control transformer, 1000 VA

More from Dongan

View all Dongan parts
Dongan
Dongan
Dongan 50-0100-056, single-phase control transformer, 100 VA
Dongan
Dongan
Dongan HC-0100-47, single-phase control transformer, 100 VA
Dongan
Dongan
Dongan FP12-551, single-phase control transformer, 5.0 kVA
Dongan
Dongan
Dongan IC-0100-104, single-phase control transformer, 100 VA
Dongan
Dongan
Dongan BR-734-4, single-phase control transformer, 375 VA
Dongan
Dongan
Dongan HC-0100-46, single-phase control transformer, 100 VA
Dongan
Dongan
Dongan 33-050-26, single-phase control transformer, 0.050 kVA, 277 V primary / 24 V secondary, 50/60 Hz
Dongan
Dongan
Dongan IC-0100-109, single-phase control transformer, 100 VA