Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

DRAEGER Detector Tube: DRAEGER Accuro, H2O, Gas Detection Tube, Water Vapor ( H2O ) - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Detector Tube: DRAEGER Accuro, H2O, Gas Detection Tube, Water Vapor ( H2O )

The DRAEGER Detector Tube for Accuro pumps detects water vapor (H2O) with a measurement range of 20 to 250 ppm, supplied in a 10-pack (MPN 8103061). 3G Electric interprets this demand and delivers genuine industrial…

SKU 3G-OTH-548672

Merek
DRAEGER
Item
Detector Tube: DRAEGER Accuro, H2O, Gas Detection Tube, Water Vapor
Kategori
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

DRAEGER
Manufacturer Part Number
8103061
Type
H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK
Gas Detected
Water Vapor
Measurement Range
20 to 250 ppm
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

DRAEGER Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The DRAEGER Detector Tube for Accuro pumps detects water vapor (H2O) with a measurement range of 20 to 250 ppm, supplied in a 10-pack (MPN 8103061). 3G Electric interprets this demand and delivers genuine industrial equipment across 14 departments—and far more—with specialist depth in combustion, pumps, and controls as an authorized distributor for brands like Schneider, ABB, Siemens, SKF, Festo, Fluke, Interpump, and FBR.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the DRAEGER Detector Tube 8103061 used for?

The DRAEGER Detector Tube 8103061 is used to detect water vapor (H2O) in industrial environments, measuring concentrations from 20 to 250 ppm. It is designed for use with DRAEGER Accuro pumps, helping plant engineers and maintenance teams monitor moisture levels in compressed air, gas streams, or process atmospheres.

What are the specifications of the DRAEGER H2O detection tube?

The DRAEGER H2O detection tube (MPN 8103061) detects water vapor with a measurement range of 20 to 250 ppm. It comes in a 10-pack and is compatible with DRAEGER Accuro pumps. This tube provides reliable spot-checking for moisture in gas systems, supporting quality control and equipment protection.

Where to buy DRAEGER Accuro gas detection tubes worldwide?

3G Electric supplies genuine DRAEGER Accuro gas detection tubes worldwide, handling full logistics and customs clearance. As a global industrial solutions provider with specialist depth in combustion, pumps, and controls, we source and deliver the H2O tube (8103061) and other detection tubes to your facility, ensuring compliance with your procurement requirements.

How to use the DRAEGER Accuro tube for water vapor detection?

To use the DRAEGER Accuro tube for water vapor detection, break off both tips of the tube, insert it into the Accuro pump, and follow the pump's stroke count for the 20 to 250 ppm range. Read the color change against the printed scale. Always refer to the manufacturer's instructions for proper handling and storage to ensure accurate results.

DRAEGER Produk

3G Electric memasok DRAEGER gas detection tubes for use in draeger accuro pumps. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Aksesori Pompa Katup & Regulasi Motor & Penggerak Semua Produk

Lainnya dari DRAEGER

Lihat semua DRAEGER suku cadang
DRAEGER Detector Tube: DRAEGER Accuro, NH3, Gas Detection Tube, Ammonia ( NH3 ), 2 to 30 ppm, 10 PK (MPN 6733231). Key specifications — Gas Detected: Ammonia; Measurement Range: 2 to 30 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, NH3, Gas Detection Tube, Ammonia ( NH3 ), 2 to 30 ppm, 10 PK (MPN 6733231). Key specifications — Gas Detected: Ammonia; Measurement Range: 2 to 30 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, CO, Gas Detection Tube, Carbon Monoxide ( CO ), 10 PK (MPN 6733051). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 2 to 60 ppm/25 to 300 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, CO, Gas Detection Tube, Carbon Monoxide ( CO ), 10 PK (MPN 6733051). Key specifications — Gas Detected: Carbon Monoxide; Measurement Range: 2 to 60 ppm/25 to 300 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, Gas Detection Tube, Dimethyl Sulfide, 25 to 200 mg/m3, 10 PK (MPN 8103475). Key specifications — Gas Detected: Dimethyl Sulfide; Measurement Range: 25 to 200 mg/m3.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, Gas Detection Tube, Dimethyl Sulfide, 25 to 200 mg/m3, 10 PK (MPN 8103475). Key specifications — Gas Detected: Dimethyl Sulfide; Measurement Range: 25 to 200 mg/m3.
DRAEGER Detector Tube: NH3, Dosimeter Tube, Ammonia ( NH3 ), 104°F Max Op Temp [NEW], Ammonia, 10 PK (MPN 8101301). Key specifications — Gas Detected: Ammonia; Measurement Range: 10 to 750 ppm/2.5 to 200 ppm/20 to 1,500 ppm/4 to 300 ppm.
DRAEGER
DRAEGER Detector Tube: NH3, Dosimeter Tube, Ammonia ( NH3 ), 104°F Max Op Temp [NEW], Ammonia, 10 PK (MPN 8101301). Key specifications — Gas Detected: Ammonia; Measurement Range: 10 to 750 ppm/2.5 to 200 ppm/20 to 1,500 ppm/4 to 300 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, C3H4, Gas Detection Tube, Hydrocarbon ( C3H4 ), 10 PK (MPN 8103571). Key specifications — Gas Detected: Hydrocarbon; Measurement Range: 0.1 to 1.3% vol Propane 0.1 to 1.3% vol Butane 0.1 to 1.3% vol mix 1:1.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, C3H4, Gas Detection Tube, Hydrocarbon ( C3H4 ), 10 PK (MPN 8103571). Key specifications — Gas Detected: Hydrocarbon; Measurement Range: 0.1 to 1.3% vol Propane 0.1 to 1.3% vol Butane 0.1 to 1.3% vol mix 1:1.
DRAEGER Detector Tube: DRAEGER Accuro, HCl, Gas Detection Tube, Hydrogen Acid ( HCl ), 10 PK (MPN 8101511). Key specifications — Gas Detected: Hydrogen Acid; Measurement Range: 0.2 to 2% vol.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, HCl, Gas Detection Tube, Hydrogen Acid ( HCl ), 10 PK (MPN 8101511). Key specifications — Gas Detected: Hydrogen Acid; Measurement Range: 0.2 to 2% vol.
DRAEGER Detector Tube: DRAEGER Accuro, C2H4, Gas Detection Tube, Ethylene ( C2H4 ), Ethylene, 10 PK (MPN 6728051). Key specifications — Gas Detected: Ethylene; Measurement Range: 50 to 2500 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, C2H4, Gas Detection Tube, Ethylene ( C2H4 ), Ethylene, 10 PK (MPN 6728051). Key specifications — Gas Detected: Ethylene; Measurement Range: 50 to 2500 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN 8101781). Key specifications — Gas Detected: Water Vapor; Measurement Range: 20 to 40 mg/L/1 to 18 mg/L.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK (MPN 8101781). Key specifications — Gas Detected: Water Vapor; Measurement Range: 20 to 40 mg/L/1 to 18 mg/L.