Konten Lembar Data
[{"filename":"fcd_datasheet_en_297694.pdf","text":"Actuators\n FCD A 00-10 xx\n FCD A 00-15 xx\n FCD A 01-15 xx\n\n\n\n\n ACTUATORS\n\n\n\n\n Technical description Application\n The DUNGS Flow Control Drive ac- The Flow Control Drive actuators are\n tuators are programmable, electronic used to control motor-driven control\n actuators with 2-point-/3-point step and throttle valves.\n as well as analogue control. The three\n design sizes cover a torque range up In combination with the FCV... flow\n to 35 Nm. Due to the robust die-cast control valves and FCVL flow control\n housing with optical position indicator valves linear, the FCD actuators pro-\n in the cover, the actuators achieve a vide an ideal combination. Flow rates\n high protection category. Together of air or gas can therefore be precisely\n\n\n\n\n Printed in Germany • Edition 2024.12 • Nr. 297694\n with the integrated heating, the ac- controlled.\n tuators are also suitable for extreme\n ambient conditions. Certification\n CE, UKCA\n\n\n\n\n1 … 16\n\fDirection of rotation actuators\nFCD A 00-10 xx\nFCD A 00-15 xx\nFCD A 01-15 xx\n\n\n\n\n Product description • End positions freely programma-\n The DUNGS Flow Control Drive ac- ble for min. and max. position. End\n tuators FCD A xx-xx xx are suitable positions are signalled via poten-\n for precise control and adjustment tial-free relay SPDT contacts.\n of motor-driven control and throttle • Potential-free relay SPDT contact\n valves. In conjunction with an air or for evaluation of operational readi-\n gas control valve (FCV G/FCV A) or ness.\n a comparable actuator, flow rates can • Depending on the design size, two\n be precisely controlled: (only FCD A 00-10 xx) or three ad-\n • Three design sizes cover torques ditional position cam switches are\n from 3 Nm to 35 Nm. available.\n • The integrated step motor in com- • The contacts are wired to the con-\n bination with the micro-controller necting terminals potential-free.\n control enables a high-precision • The actuators have additional, di-\n control. verse setting options and features.\n • Device properties and parameters • Simple parametrisation / setting by\n are set directly on the device. rotary switch / button directly on the\n • Two-point operating mode (open/ device: rotation time, direction of\n close) and two-point operating rotation, ramp times and hysteresis.\n mode with additional intermediate • Robust aluminium housing, pro-\n position tection class IP 65 and integrated\n • Switchable between 3-point step heating ensure smooth and contin-\n and analogue control during oper- uous operation even under difficult\n ation conditions.\n • Analogue position feedback\n • Optical position indicator in the hous-\n ing cover and electronic position\n feedback (0/4 - 20 mA or 0/2 - 10 V).\n\n\n\n\n 2 … 16\n\f Actuators\n FCD A 00-10 xx\n FCD A 00-15 xx\n FCD A 01-15 xx\n\n\n\n\n Certification / Approvals\n\n\n\n\n 2014/35/EU Low Voltage Directive Conformity with the requirements Conformity with the requirements\n 2014/30/EU EMV directive for Great Britain (UK). for the Eurasian Economic Union.\n 2011/65/EU RoHS\n\n DIN EN 16340: 2014-10\n DIN EN 60730-1: 2021-06\n\n\n\n Technical data\n FCD A 00-10 FCD A 00-15 FCD A 01-15\n -- 4 Nm 12 Nm 35 Nm\n Max. torque\n S2 -- 6 Nm 18 Nm\n (adjustable)\n S4 -- 3 Nm 9 Nm\n -- 15 - 60 s / 90° 25 - 90 s / 90° 25 - 90 s / 90°\n Rotation time\n S2 -- 12 - 45 s / 90° 12 - 45 s / 90°\n (adjustable)\n S4 -- 7,5 - 25 s / 90° 7,5 - 25 s / 90°\n Resolution 1000 steps / 90°\n Max. rotation angle 110°\n AC Mains Voltage 90 - 260 VAC, 50/60 Hz\n DC Mains Voltage 18 - 30 VDC\n DC24 V: max. 4,8 W DC24 V: max. 6 W DC24 V: max. 11 W\n Power consumption\n AC: max. 5 VA AC: max. 7 VA AC: max. 15 VA\n Protection class IP65\n Ambient temperature -20 °C - 60 °C\n Weight ca. 0,8 kg ca. 1,6 kg ca. 2,2 kg\n Dimensions (BxHxT) ca. 114 x 82 x 93 mm ca. 135 x 108 x 122 mm ca. 176 x 111 x 142 mm\n 3 St. M16 x 1,5 mm 2 St. M20 x 1,5 mm 2 St. M20 x 1,5 mm\n Cable inlet\n Ø 5 - 9 mm Ø 9 - 13 mm Ø 9 - 13 mm\n\n\n\n\n3 … 16\n\fActuators\nFCD A 00-10 xx\nFCD A 00-15 xx\nFCD A 01-15 xx\n\n\n\n\nTechnical data\n FCD A 00-10 FCD A 00-15 FCD A 01-15\n\nHousing Aluminiumguss\nShaft connection 7 x 7 x 7,5 mm 9 x 9 x 9,5 mm 9 x 9 x 9,5 mm\n Internal square Internal square Internal square\nFlange connection F03, LK Ø 30, 4 x M5, F03, F05, LK Ø 4 x M6 F07, LK Ø 50, 4 x M5,\n LK Ø 50, 2 x M6 LK Ø 50, 4 x M6\nService life 500,000 cycles under full load, 2,000,000 cycles at 60 % load\nProgramming / • Operation and programming via switches and keyboard in the device\noperation • Control devices can be accessed when the housing is open\n2-Point-step control • Open & close via potential-free inputs\n2-Point-step control with • Open & close via potential-free inputs\nintermediate position • Intermediate position via an additional digital input\n3-Point-step control • Open & close via potential-free inputs\n • Control release switches between 3-point step and analogue control\n • Adjustable start ramp\nAnalogue operating mode • Control release switches between 3-point step and analogue control\n up to 1,000 steps/90°:\n • adjustable step size\n • adjustable averaging for analogue input\n • adjustable safe position\n • adjustable ramp\nAnalogue control 0/4 - 20 mA Selectively 0/4 - 20 mA oder 0/2 - 10 V\nPosition feedback 0/4 - 20 mA Selectively 0/4 - 20 mA oder 0/2 - 10 V\nMin./max. end positions • End positions freely programmable for min. and max. position on the device\n • End positions are signalled via relay outputs (SPDT)\nFree cam switch • Two adjustable cam \t\t • Two adjustable cam \t\t • Three adjustable cam \t\t\n switches switches switches\n • NO or NC selectable via • Potential-free SPDT • Potential-free SPDT\n slide switch contacts contacts\nStatus message • Relay output for reporting operational readiness\n • Potential-free SPDT contacts\n\n\n\n\n 4 … 16\n\f Actuators\n FCD A 00-10 xx\n FCD A 00-15 xx\n FCD A 01-15 xx\n\n\n\n\n Technical data\n FCD A 00-10 FCD A 00-15 FCD A 01-15\n Electric specifications Analogue position feedback\n of the inputs and outputs • Power source: \t\t max. 12 V output voltage, load max. 500 Ω\n • Voltage source: max. 12 V output voltage, max. 30 mA current\n\n Analogue setpoint specification\n • max. input voltage: 12 V, current input, load 500 Ω\n\n Relay outputs\n • Switching load AC: max. 250 V, 500 mA, resistive load\n…