We ship to Indonesia — door-to-door, customs and logistics handled by 3G Electric

DUNGS G...A2 - Pressure Switches and Pressure Limiters for gas, air
DungsPressure switch

DUNGS G...A2 - Pressure Switches and Pressure Limiters for gas, air

Sakelar tekanan gas DUNGS seri GAO-A2, GMH-A2, dan GML-A2 adalah komponen kompak tanpa ventilasi yang dirancang untuk aplikasi rangkaian gas modular pada sistem pembakaran industri dan komersial. Sakelar ini…

SKU 3G-OTH-02962

Also listed as: GAOGMLGMHA2USCA · GAO GML GMH A2 US CA

Brand
Dungs
Item
G...A2 - Pressure Switches and Pressure Limiters for gas, air
Category
Pressure switch
Available to Order
Ready stock & customs handled
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Ships to: Jakarta, Surabaya, Bandung, Medan, Batam
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Indonesia

Phone
+65 8878 8355

Datasheet Content

[{"filename":"gao-gml-gmh-a2_datasheet_us_226359.pdf","text":"Gas Pressure Switch\n for DMV safety shutoff valves\n\n GAO-A2…\n GMH-A2…\n GML-A2…\n\n\n\n\n UL Listed\n • UL 353\n • File # MH 16628\n\n CSA Certified\n • CSA C22.2 No. LR 53222\n • File # 201527\n\n FM Approved\n • Class 3510, 3530\n • File # J.I. 1Y9A9.AF\n\n Commonwealth of Massachusetts\n Approved Product\n • Approval code G3-0106-191\n • Gas pressure switch\n\n Codes and Standards\n This product is intended for instal-\n lations covered by but not limited to\n NFPA 85, NFPA 86, UL 795, CSD-1,\n ANSI Z83.4, ANSI Z83.18, ANSI\n Z21.13, CSA B149.1, CSA B149.3 and\n CSA B149.6.\n\n DUNGS is an ISO 9001 Description Application\n manufacturing facility. The GAO-, GMH-, and GML-A2… pres- The GAO-, GMH-, and GML-A2…\n sure switches are compact, ventless gas pressure switches are recommended\n pressure switches for modular valve train for industrial and commercial heating\n components. applications with DMV dual modular\n valves, SV safety valves, MBC, MBE\n These pressure switches are suitable for multifunctional controls, and FRI modu-\n making and/or breaking a circuit when lar pressure regulators. Various mount-\n the medium pressure changes relative ing options allow direct mounting on the\n to the set point. The set point can be set valve housing.\n\n\n\n\n Gxx-A2 Sales Brochure • P/N 226359 • Ed. 10/23\n in the field by an adjustable dial with an\n integrated scale. The switches incor- The GAO-, GMH-, and GML-A2… pres-\n porate a vent limiter as per UL 353 and sure switch is suitable for dry natural\n limits the escape of gas less than 1.0 gas, propane, butane, air and other\n CFH of natural gas at 7 PSI if internal inert gases. Suitable for up to 0.1 % by\n switch diaphragm ruptures. volume, dry H2S.\n\n A “dry” gas has a dew point lower than\n +15 °F and its relative humidity is less\n than 60 %.\n1…7\n\fGAO-A2… SPDT pressure switch requires no auxiliary power to actuate. The GAO-A2… is suitable for making and/or\nbreaking a circuit when the set point is exceeded or undershot. A tripped switch is indicated by a neon light after set point\nis exceeded or undershot. Automatic reset when pressure returns below or above set point.\n\nGMH-A2… SPDT pressure switch requires no auxiliary power to actuate. The GMH-A2… is suitable for making and/or\nbreaking a circuit when the set point is exceeded. A tripped switch (only NEMA Type 4) is indicated by a neon light after\nset point is exceeded.Manual reset is required to reset the switch.\n\nGML-A2… SPDT pressure switch requires no auxiliary power to actuate. The GML-A2… is suitable for making and/or\nbreaking a circuit when the set point is undershot. A tripped switch (only NEMA Type 4) is indicated by a neon light after\nset point is undershot.Manual reset is required to reset the switch.\n\nSpecifications\nMax. operating pressure GAO-A2-4-2,3,5,6 7 PSI (500mbar)\n GMH- and GML-A2-4-4,6 7 PSI (500mbar)\n GAO-, GMH- and GML-A2-4-8 14 PSI (1000 mbar)\nPressure connection O-ring flange connection on underside of pressure switch\nTemperature range:\nFor series ending in -2,-3,-5, and -6 Ambient temperature -40 °F to +140 °F (-40 °C to +60 °C)\n Medium temperature -40 °F to +140 °F (-40 °C to +60 °C)\nFor series ending in -8 Ambient temperature -22 °F to +140 °F (-30 °C to +60 °C)\n Medium temperature -22 °F to +140 °F (-30 °C to +60 °C)\nMaterials Housing Aluminium\n Switch Polycarbonate\n Diaphragm NBR-based rubber\n Switching contact Silver\nElectrical ratings AC eff.\t\t min. 24 V max. 240 V\n DC \t\t min. 24 V max. 48 V\nNominal current ratings Silver (Ag) contact ratings\t\t\n AC 10 A resistive @ 120 VAC\n AC 8 A pilot duty @ 120 VAC\n DC min. 20 mA @ 24 VDC\n DC max. 1 A @ 24 - 48 VDC\t\t\nIndication light (NEMA 4 versions) Energy consumption\n 0.1 W max. @ 120 VAC\n 0.5 W max. @ 24 VDC/AC\nElectrical connection Screw terminals via 1/2\" NPT conduit connection\nEnclosure rating NEMA 1 or NEMA 4\nSetting tolerance ±15% switching point deviation referred to set point. Adjusted as pressure rises or\n as pressure falls, vertical diaphragm position.\nVent Limiter Incorporates a vent limiter as per UL 353 and limits the escape of gas less than 1.0\n CFH of natural gas at 7 PSI if internal switch diaphragm ruptures.\n\n\nGAO (Shown as a high gas limit) GMH (Operating state shown) GML (Operating state shown)\nAs pressure rises above set point, As pressure rises, 2 NO closes, As pressure falls, 2 NO opens, 1 NC\n1 NC opens, 2 NO closes, Neon light 1 NC opens, and Neon light ON (fault), closes, Neon light ON (fault), switch\nON (fault). As pressure falls below switch trips and locks out. trips and locks out.\nsetpoint, switch resets: 1 NC closes\nand 2 NO opens, Neon light off.\n\n\n\n\n O (orange) O (orange)\n O (orange) Medium NE (neon) Medium NE (neon)\n Medium NE (neon) Pressure Pressure\n Pressure NEMA 4 NEMA 4\n NEMA 1 no light installed NEMA 1 no light installed 2…7\n\f Dimensions inch (mm)\n GAO-, GMH-, GML-A2…\n\n\n\n\n Through hole\n 4 x 0.16 (4,2)\n\n\n\n\n Reset button\n GMH-A2...\n GML-A2... Slot for O-ring\n\n\n\n NEMA 1\n cover has\n 20 mm cutout\n\n\n\n\n NPT 1/2”\n conduit connection\n\n\n\n Adapters / Replacement parts / Order No. For equipment Notes\n Accessories\n A2 Mounting kit (included with switch) 226188 GAO, GMH, GML M4 Screws, 10.5 x 2.25 O-ring\n DMV & MBC Port 3 adapter 273777 DMV-D(LE) 701 - 703 NPT 1/2“ - NPT 2“\n (side mount for high pressure switch MBC series 1000 - 4000\n Replacement conduit adapter 220566 GAO, GMH, GML PG 11 to 1/2“ NPT adapter\n Replacement conduit adapter 240671 GAO, GMH, GML M 20 to 1/2“ NPT adapter\n NEMA 4 Replacement cover 228732 GAO\n 233113 GMH, GML\n NEMA 1 Replacement cover 298234 GMH, GML\n Screw for replacement…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Sakelar tekanan gas DUNGS seri GAO-A2, GMH-A2, dan GML-A2 adalah komponen kompak tanpa ventilasi yang dirancang untuk aplikasi rangkaian gas modular pada sistem pembakaran industri dan komersial. Sakelar ini berfungsi untuk membuat dan/atau memutus sirkuit ketika tekanan medium berubah relatif terhadap titik setel yang dapat disesuaikan melalui dial dengan skala terintegrasi. Dilengkapi pembatas ventilasi sesuai UL 353 yang membatasi kebocoran gas kurang dari 1,0 CFH gas alam pada 7 PSI jika diafragma internal rusak. Produk ini memiliki sertifikasi UL, CSA, FM, dan disetujui oleh Commonwealth of Massachusetts, serta cocok untuk gas alam kering, propana, butana, udara, dan gas inert lainnya dengan kandungan H2S kering hingga 0,1% volume.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Frequently Asked Questions

Untuk apa sakelar tekanan gas DUNGS GAO-A2 digunakan?

Sakelar tekanan gas DUNGS GAO-A2 digunakan untuk membuat dan/atau memutus sirkuit ketika tekanan gas berubah relatif terhadap titik setel. Produk ini direkomendasikan untuk aplikasi pemanas industri dan komersial yang menggunakan katup modular ganda DMV, katup pengaman SV, kontrol multifungsi MBC/MBE, dan regulator tekanan modular FRI.

Apa spesifikasi teknis sakelar tekanan gas DUNGS seri Gxx-A2?

Sakelar tekanan gas DUNGS seri GAO-A2, GMH-A2, dan GML-A2 adalah sakelar SPDT yang tidak memerlukan daya tambahan untuk beroperasi. Sakelar ini memiliki pembatas ventilasi sesuai UL 353 yang membatasi kebocoran gas kurang dari 1,0 CFH gas alam pada 7 PSI. Titik setel dapat disesuaikan di lapangan melalui dial dengan skala terintegrasi, dan sakelar yang terpicu ditandai dengan lampu neon.

Gas apa saja yang cocok untuk sakelar tekanan DUNGS Gxx-A2?

Sakelar tekanan DUNGS GAO-A2, GMH-A2, dan GML-A2 cocok untuk gas alam kering, propana, butana, udara, dan gas inert lainnya. Gas kering memiliki titik embun lebih rendah dari +15°F dan kelembaban relatif kurang dari 60%. Produk ini juga cocok untuk aplikasi dengan kandungan H2S kering hingga 0,1% volume.

Sertifikasi apa yang dimiliki sakelar tekanan gas DUNGS Gxx-A2?

Sakelar tekanan gas DUNGS seri GAO-A2, GMH-A2, dan GML-A2 memiliki sertifikasi UL 353 (File # MH 16628), CSA C22.2 No. LR 53222 (File # 201527), FM Approved Class 3510/3530 (File # J.I. 1Y9A9.AF), dan disetujui oleh Commonwealth of Massachusetts (Kode G3-0106-191). Produk ini diproduksi di fasilitas bersertifikasi ISO 9001.

Di mana beli sakelar tekanan gas DUNGS Gxx-A2 di Indonesia?

Anda dapat membeli sakelar tekanan gas DUNGS seri GAO-A2, GMH-A2, dan GML-A2 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ini ke seluruh Indonesia. Tim kami menangani logistik dan bea cukai sehingga Anda dapat menerima produk dengan aman. Hubungi kami untuk minta penawaran.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs pressure switch. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DUNGS G...A4 - Pressure Switches and Pressure Limiters for gas, air, flue and exhaust gases (US/CA)
Dungs
DUNGS G...A4 - Pressure Switches and Pressure Limiters for gas, air, flue and exhaust gases (US/CA)
DUNGS GGAO...A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen (US/CA)
Dungs
DUNGS GGAO...A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen (US/CA)
DUNGS AA-A2 - Pressure Switches for air, flue and exhaust gases (US/CA)
Dungs
DUNGS AA-A2 - Pressure Switches for air, flue and exhaust gases (US/CA)
DUNGS GGW...A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
Dungs
DUNGS GGW...A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
DUNGS LGW...A2 - Pressure Switches for air, flue and exhaust gases
Dungs
DUNGS LGW...A2 - Pressure Switches for air, flue and exhaust gases

More from Dungs

View all Dungs parts
DUNGS AA-A4 - Pressure Switches for air, flue, exhaust gases (US/CA)
Dungs
DUNGS AA-A4 - Pressure Switches for air, flue, exhaust gases (US/CA)
DUNGS GW...A5 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen for multifunctional device
Dungs
DUNGS GW...A5 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen for multifunctional device
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application (US/CA)
Dungs
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application (US/CA)
DUNGS ÜB, NB...A2 - Pressure Limiters for gas, air, flue, exhaust gases and hydrogen for multifunctional gas controls
Dungs
DUNGS ÜB, NB...A2 - Pressure Limiters for gas, air, flue, exhaust gases and hydrogen for multifunctional gas controls
DUNGS GW...A6 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen
Dungs
DUNGS GW...A6 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen
DUNGS GW 500 A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
Dungs
DUNGS GW 500 A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
DUNGS AA-A1 - Pressure Switches for air, factory adjusted (US/CA)
Dungs
DUNGS AA-A1 - Pressure Switches for air, factory adjusted (US/CA)
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application
Dungs
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application