Dwyer Seri 1950 Sakelar Tahan Ledakan Di: Dapat Disesuaikan, 4 in wc hingga 20 in wc, Enclosure NEMA-3 - Hazardous Location Adjustable Set-Point Air Pressure Switches
DwyerHazardous Location Adjustable Set-Point Air Pressure Switches

Dwyer Seri 1950 Sakelar Tahan Ledakan Di: Dapat Disesuaikan, 4 in wc hingga 20 in wc, Enclosure NEMA-3

Dwyer Series 1950 Explosion Proof Differential Pressure Switch adalah sakelar tekanan udara dengan set-point yang dapat disesuaikan, dirancang khusus untuk lokasi berbahaya. Produk ini memiliki rentang set-point 4 in…

SKU 3G-OTH-68262

Juga terdaftar sebagai: 1950202F · 1950 20 2F

Merek
Dwyer
Item
Seri 1950 Sakelar Tahan Ledakan Di: Dapat Disesuaikan, 4 in wc hingga 20 in wc, Enclosure NEMA-3
Part Number
1950-20-2F
Kategori
Hazardous Location Adjustable Set-Point Air Pressure Switches
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

Dwyer
Manufacturer Part Number
1950-20-2F
Type
4 in wc to 20 in wc, NEMA-3 Enclosure, SPDT, NPT
NPT
1/8 in

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

Dwyer Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Dwyer Series 1950 Explosion Proof Differential Pressure Switch adalah sakelar tekanan udara dengan set-point yang dapat disesuaikan, dirancang khusus untuk lokasi berbahaya. Produk ini memiliki rentang set-point 4 in wc hingga 20 in wc, dilengkapi dengan enclosure NEMA-3, kontak SPDT, dan koneksi NPT 1/8 in. Sakelar tekanan ini ideal untuk aplikasi pengaman dan kontrol di lingkungan industri yang memerlukan perlindungan terhadap ledakan.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Untuk apa Dwyer Series 1950 digunakan?

Dwyer Series 1950 digunakan sebagai sakelar tekanan udara yang dapat disetel untuk memonitor dan mengontrol tekanan diferensial di lokasi berbahaya. Produk ini cocok untuk sistem ventilasi, filter, dan pengaman ketel uap di industri minyak sawit, semen, atau kelautan.

Apa spesifikasi Dwyer Series 1950-20-2F?

Spesifikasi Dwyer Series 1950-20-2F meliputi rentang set-point 4 in wc hingga 20 in wc, enclosure NEMA-3, kontak SPDT, dan koneksi NPT 1/8 in. Produk ini dirancang untuk lokasi berbahaya dan memiliki sertifikasi explosion-proof.

Di mana beli Dwyer Series 1950 di Indonesia?

Anda dapat membeli Dwyer Series 1950 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi industri Anda.

Bagaimana cara memilih set-point yang tepat untuk Dwyer Series 1950?

Pilih set-point berdasarkan kebutuhan tekanan diferensial sistem Anda. Dwyer Series 1950 dapat disetel antara 4 in wc hingga 20 in wc. Pastikan rentang ini sesuai dengan tekanan operasi normal dan ambang batas alarm atau cutoff yang diinginkan.

Digunakan dalam

Aplikasi umum untuk Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management
Not sure this is the right part? Photo-identify it

Dwyer Produk

3G Electric memasok Dwyer hazardous location adjustable set-point air pressure switches. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Auto-reset adjustable pressure switch with SPDT contacts rated for 120 to 480V AC. Set-point range of 5 in wc to 44 in wc. Features a NPT connection and conduit box. Used in HVAC and industrial air pressure monitoring and control applications
This adjustable set-point air pressure switch from Dwyer features a SPDT switching element and a sample line connection size of 1/8 in NPT. It has an adjustable range of 4 to 20 inches of water column and operates at 120 to 480V AC. Commonly used in HVAC and industrial process systems to monitor or control air pressure
Dwyer
This adjustable set-point air pressure switch from Dwyer features a SPDT switching element and a sample line connection size of 1/8 in NPT. It has an adjustable range of 4 to 20 inches of water column and operates at 120 to 480V AC. Commonly used in HVAC and industrial process systems to monitor or control air pressure
Adjustable set-point air pressure switch with a range of 0.4 in wc to 1.6 in wc. Features SPDT contact configuration, 1/8 in NPT sample line connection, and 250V AC switch voltage rating. Suitable for monitoring or controlling air pressure in HVAC, ventilation, and industrial process systems
Dwyer
Adjustable set-point air pressure switch with a range of 0.4 in wc to 1.6 in wc. Features SPDT contact configuration, 1/8 in NPT sample line connection, and 250V AC switch voltage rating. Suitable for monitoring or controlling air pressure in HVAC, ventilation, and industrial process systems
Dwyer
Dwyer
Auto reset adjustable set-point air pressure switch with a range of 9 to 85 in wc. Features SPDT switch action, NPT connection, and a conduit box. Operates on 120 to 480V AC. Used in HVAC and air-handling systems for alarm, shutdown, or fan control

Lainnya dari Dwyer

Lihat semua Dwyer suku cadang
Adjustable set-point air pressure switch for hazardous locations. Range 0.15 to 0.5 in wc. NEMA-3 enclosure, SPDT contacts, 1/8 in NPT connection. Used for low-pressure monitoring in ventilation, filter, and safety interlock systems
Dwyer
Adjustable set-point air pressure switch for hazardous locations. Range 0.15 to 0.5 in wc. NEMA-3 enclosure, SPDT contacts, 1/8 in NPT connection. Used for low-pressure monitoring in ventilation, filter, and safety interlock systems
Adjustable set-point air pressure switch for hazardous locations. Range 0.07 in wc to 0.15 in wc. NEMA-3 enclosure, SPDT contacts, 1/8 in NPT connection. Used for sensing low differential pressure in HVAC, ventilation, and process control systems
Dwyer
Adjustable set-point air pressure switch for hazardous locations. Range 0.07 in wc to 0.15 in wc. NEMA-3 enclosure, SPDT contacts, 1/8 in NPT connection. Used for sensing low differential pressure in HVAC, ventilation, and process control systems
Auto reset differential pressure switch with adjustable set-point from 0 to 45 in wc. Features a NEMA-3 enclosure, SPDT contacts rated at 480V AC, and NPT connection. Suitable for monitoring and controlling air pressure in hazardous environments
Dwyer
Auto reset differential pressure switch with adjustable set-point from 0 to 45 in wc. Features a NEMA-3 enclosure, SPDT contacts rated at 480V AC, and NPT connection. Suitable for monitoring and controlling air pressure in hazardous environments
Dwyer
Dwyer
Adjustable differential pressure switch for hazardous locations, with a set-point range of 0.5 psid to 2 psid. Features a standard housing, SPDT switch, 1/8 in NPT connections, and 250V AC rating. Used for monitoring and controlling air pressure in HVAC duct static pressure, filter monitoring, and industrial ventilation systems
Dwyer
Dwyer
This adjustable set-point air pressure switch is designed for hazardous locations, with a differential pressure range of 0.07 in wc to 0.15 in wc. It features a NEMA-3 enclosure, SPDT switch action, and NPT connections, operating on 24V DC. Typical applications include pressure monitoring in HVAC systems, industrial ventilation, and safety interlocks
Dwyer
Dwyer
Adjustable differential pressure switch for hazardous locations, set-point range 3 psid to 15 psid. Features SPDT switch, standard housing, and 1/8 in NPT connections. Rated for 250V AC. Used for monitoring and controlling air pressure in HVAC, filter monitoring, and industrial ventilation systems
Single operation reset type switch with adjustable set-point range of 1.4 to 5.5 in wc. SPDT output with NPT connection. Suitable for sensing differential air pressure in hazardous environments
Dwyer
Single operation reset type switch with adjustable set-point range of 1.4 to 5.5 in wc. SPDT output with NPT connection. Suitable for sensing differential air pressure in hazardous environments
Single operation reset type. Adjustable set-point range of 3 in wc to 11 in wc. NEMA-3 enclosure. Used in HVAC, ventilation, and process control systems for monitoring or controlling air pressure in hazardous locations