EATON Power Defense Molded Case Circuit Breaker - Power Defense Molded Case Circuit Breakers
EATONPower Defense Molded Case Circuit Breakers

EATON Power Defense Molded Case Circuit Breaker

EATON Power Defense Molded Case Circuit Breaker (MCB) seri PDG21M0020TFFL adalah pemutus sirkuit industri dengan rating arus 20 A dan kapasitas pemutusan maksimum 65kA pada 480V AC. Dilengkapi dengan sambungan beban…

SKU 3G-OTH-24094

Merek
EATON
Item
Power Defense Molded Case Circuit Breaker
Kategori
Power Defense Molded Case Circuit Breakers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

EATON
Manufacturer Part Number
PDG21M0020TFFL
Series
PD Series
Type
65kA at 480V AC, Fixed, ABC, Load Side Lug, Std
Frame Size
2
Max. AIR Rating
65kA at 480V AC
Phase Connection
ABC
Instantaneous Trip
Fixed
Terminal Connection
Load Side Lug

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

EATON Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

EATON Power Defense Molded Case Circuit Breaker (MCB) seri PDG21M0020TFFL adalah pemutus sirkuit industri dengan rating arus 20 A dan kapasitas pemutusan maksimum 65kA pada 480V AC. Dilengkapi dengan sambungan beban (Load Side Lug) dan trip instan tetap (Fixed Instantaneous Trip) untuk perlindungan yang andal pada sistem distribusi listrik. Produk ini termasuk dalam seri PD Series dengan frame size 2 dan koneksi fase ABC, cocok untuk aplikasi proteksi sirkuit di berbagai peralatan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi EATON PDG21M0020TFFL?

EATON PDG21M0020TFFL adalah Molded Case Circuit Breaker dengan rating arus 20 A, kapasitas pemutusan maksimum 65kA pada 480V AC, tipe trip instan tetap (Fixed Instantaneous Trip), koneksi fase ABC, dan terminal sambungan beban (Load Side Lug). Frame size 2, seri PD Series.

Untuk apa EATON Power Defense MCB digunakan?

EATON Power Defense MCB digunakan sebagai pemutus sirkuit untuk melindungi peralatan listrik dari arus lebih dan hubung singkat pada sistem distribusi tegangan rendah. Cocok untuk aplikasi industri seperti panel listrik, mesin produksi, dan sistem kontrol.

Di mana beli EATON PDG21M0020TFFL di Indonesia?

Anda dapat membeli EATON PDG21M0020TFFL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu ke lokasi Anda.

Apa perbedaan antara trip tetap dan trip adjustable pada MCB?

Pada EATON PDG21M0020TFFL, trip instan tetap (Fixed Instantaneous Trip) berarti nilai trip tidak dapat diubah, memberikan perlindungan konsisten pada 20 A. Sementara trip adjustable memungkinkan penyesuaian nilai trip sesuai kebutuhan aplikasi.

Bagaimana cara memilih MCB yang tepat untuk panel listrik industri?

Pilih MCB berdasarkan rating arus (20 A), kapasitas pemutusan (65kA pada 480V AC), dan jenis trip (Fixed Instantaneous Trip). Pastikan sesuai dengan beban dan sistem distribusi Anda. EATON PDG21M0020TFFL dengan frame size 2 dan koneksi ABC cocok untuk aplikasi industri umum.

Digunakan dalam

Aplikasi umum untuk EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Produk

3G Electric memasok EATON power defense molded case circuit breakers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Molded case circuit breaker rated 30 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 30 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
EATON Power Defense molded case circuit breaker, 15 A, PD Series, Frame Size 2. Maximum AIR rating 65 kA at 480 V AC, fixed instantaneous trip, ABC phase connection, load side lug terminals. Provides overcurrent protection in electrical distribution systems
EATON
EATON Power Defense molded case circuit breaker, 15 A, PD Series, Frame Size 2. Maximum AIR rating 65 kA at 480 V AC, fixed instantaneous trip, ABC phase connection, load side lug terminals. Provides overcurrent protection in electrical distribution systems
Molded case circuit breaker rated 225 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 225 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
Molded case circuit breaker rated 20 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 20 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
Molded case circuit breaker from the Power Defense PD Series, rated 100 A with a maximum interrupting rating of 65kA at 480V AC. Features instantaneous trip characteristic, ABC phase connection, and line/load lug terminals. Suitable for use in power distribution systems, switchboards, and panelboards requiring overcurrent protection
EATON
Molded case circuit breaker from the Power Defense PD Series, rated 100 A with a maximum interrupting rating of 65kA at 480V AC. Features instantaneous trip characteristic, ABC phase connection, and line/load lug terminals. Suitable for use in power distribution systems, switchboards, and panelboards requiring overcurrent protection
Molded case circuit breaker rated 20 A with a maximum interrupting rating of 65kA at 480V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 20 A with a maximum interrupting rating of 65kA at 480V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in electrical distribution systems

Lainnya dari EATON

Lihat semua EATON suku cadang
EATON Circuit Breaker: 50 A Amps, 35 kA at 480V AC, Fixed, ABC, Std Terminals Load Only, Std (MPN PDG23G0050TFFL)
EATON
EATON Circuit Breaker: 50 A Amps, 35 kA at 480V AC, Fixed, ABC, Std Terminals Load Only, Std (MPN PDG23G0050TFFL)
125 A, Frame 1 molded case circuit breaker with a maximum AIR rating of 65 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for overload and short-circuit protection in power distribution systems
EATON
125 A, Frame 1 molded case circuit breaker with a maximum AIR rating of 65 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for overload and short-circuit protection in power distribution systems
Molded case circuit breaker rated 125 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in industrial power distribution, motor control centers, and panelboards
EATON
Molded case circuit breaker rated 125 A with a maximum interrupting rating of 65 kA at 480 V AC. Fixed instantaneous trip, ABC phase connection, and load side lug terminals. Suitable for overcurrent protection in industrial power distribution, motor control centers, and panelboards
Molded case circuit breaker rated 400 A with 800A/Frame 4 frame size. Maximum interrupting rating of 35 kA at 480V AC. Fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for main or feeder protection in industrial and commercial electrical systems
EATON
Molded case circuit breaker rated 400 A with 800A/Frame 4 frame size. Maximum interrupting rating of 35 kA at 480V AC. Fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for main or feeder protection in industrial and commercial electrical systems
This 2-pole molded case circuit breaker is rated 15 A with a 125A/Frame 1 frame size. It provides a maximum interrupting rating of 65 kA at 480V AC and features a fixed instantaneous trip. The AB phase connection and standard line and load lugs facilitate installation in panelboards and switchboards for branch-circuit protection
EATON
This 2-pole molded case circuit breaker is rated 15 A with a 125A/Frame 1 frame size. It provides a maximum interrupting rating of 65 kA at 480V AC and features a fixed instantaneous trip. The AB phase connection and standard line and load lugs facilitate installation in panelboards and switchboards for branch-circuit protection
This 3-pole molded case circuit breaker is rated 30 A with a 125A/Frame 1 frame size. It provides an interrupting capacity of 18 kA at 480V AC and features a fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for branch circuit protection in power distribution systems
EATON
This 3-pole molded case circuit breaker is rated 30 A with a 125A/Frame 1 frame size. It provides an interrupting capacity of 18 kA at 480V AC and features a fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for branch circuit protection in power distribution systems
Molded case circuit breaker rated 150 A with 225A/Frame 2 frame size. Maximum interrupting rating 50 kA at 480V AC. Fixed instantaneous trip, ABC phase connection, standard line and load lugs. Suitable for branch feeder protection in power distribution systems
EATON
Molded case circuit breaker rated 150 A with 225A/Frame 2 frame size. Maximum interrupting rating 50 kA at 480V AC. Fixed instantaneous trip, ABC phase connection, standard line and load lugs. Suitable for branch feeder protection in power distribution systems
Molded case circuit breaker rated 300 A with a 600A/Frame 3 frame size. Provides 65 kA interrupting capacity at 480V AC. Features fixed instantaneous trip, adjustable long-time and short-time settings, ABC phase connection, and standard line and load lugs. Suitable for overload and short-circuit protection in panelboards, switchboards, and motor control centers
EATON
Molded case circuit breaker rated 300 A with a 600A/Frame 3 frame size. Provides 65 kA interrupting capacity at 480V AC. Features fixed instantaneous trip, adjustable long-time and short-time settings, ABC phase connection, and standard line and load lugs. Suitable for overload and short-circuit protection in panelboards, switchboards, and motor control centers