Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

3G Electric
Gambar tidak tersedia
EATONEaton S711

EATON S711-34140AC Soft Start with Bypass, 140 A, 200-575V AC, Three Phase

EATON S711 adalah soft starter tiga fase dengan bypass internal, dirancang untuk aplikasi industri yang memerlukan pengasutan motor secara bertahap. Model ini memiliki Output Current 140 A, rentang tegangan 200-575V…

SKU 3G-OTH-54696

Juga terdaftar sebagai: S71134140AC · S711 34140AC

Merek
EATON
Item
S711-34140AC Soft Start with Bypass, 140 A, 200-575V AC, Three Phase
Part Number
S711-34140AC
Kategori
Eaton S711
Tersedia untuk Dipesan
Also known as:S711-34140ACEATON
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

EATON
Manufacturer Part Number
S711-34140AC
Type
With Bypass, IP00, 60/50 Hz, Three Phase
Output Current
140 A
Control Voltage
110-240V AC

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

EATON Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

EATON S711 adalah soft starter tiga fase dengan bypass internal, dirancang untuk aplikasi industri yang memerlukan pengasutan motor secara bertahap. Model ini memiliki Output Current 140 A, rentang tegangan 200-575V AC, dan Control Voltage 110-240V AC. Soft starter ini beroperasi pada frekuensi 60/50 Hz dengan tingkat proteksi IP00, cocok untuk dipasang di panel kontrol. Sebagai distributor resmi EATON, 3G Electric menyediakan soft starter ini untuk kebutuhan peralatan industri di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi EATON S711 soft starter?

EATON S711 memiliki spesifikasi: tipe with bypass, IP00, 60/50 Hz, three phase, Output Current 140 A, Control Voltage 110-240V AC, dan rentang tegangan 200-575V AC. Nomor komponennya adalah S711-34140AC.

Untuk apa EATON S711 digunakan?

EATON S711 digunakan sebagai soft starter untuk mengasut motor listrik tiga fase secara bertahap, mengurangi lonjakan arus start dan tekanan mekanis. Cocok untuk aplikasi industri seperti pompa, kompresor, dan konveyor.

Di mana beli EATON S711 di Indonesia?

Anda dapat membeli EATON S711 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman tepat waktu.

Bagaimana cara memilih EATON S711 yang tepat?

Pilih EATON S711 berdasarkan tegangan suplai (200-575V AC), arus motor (Output Current 140 A), dan Control Voltage (110-240V AC). Pastikan juga frekuensi sistem Anda 60/50 Hz dan tingkat proteksi IP00 sesuai untuk pemasangan di panel.

Digunakan dalam

Aplikasi umum untuk EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas
Not sure this is the right part? Photo-identify it

EATON Produk

3G Electric memasok EATON eaton s711. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON
EATON
Three-phase soft start with bypass, rated for 170 A output current and 110-240V AC control voltage. Operates at 60/50 Hz with IP00 enclosure. Used to control motor acceleration and deceleration in applications such as conveyors, pumps, and compressors, reducing mechanical stress and electrical inrush current
EATON
EATON
Three-phase soft start with bypass for motor acceleration and deceleration. Rated 250 A output current, 110-240V AC control voltage, 60/50 Hz. IP00 enclosure. Used in industrial applications such as conveyors, pumps, and compressors to reduce mechanical stress and electrical inrush current
EATON
EATON
Three-phase soft start with bypass, rated 140 A output current at 60/50 Hz. Control voltage 24V DC. IP00 enclosure. Used to control motor acceleration in industrial applications such as pumps, fans, and conveyors, reducing mechanical stress and electrical surges
EATON
EATON
Three-phase soft start with bypass, rated 560 A output current at 60/50 Hz. Control voltage 110-240V AC. IP00 enclosure. Used to control motor acceleration and deceleration in applications such as pumps, conveyors, and compressors, reducing mechanical stress and electrical inrush current
EATON
EATON
Three-phase soft start with integrated bypass for controlling motor acceleration in industrial applications such as pumps, fans, conveyors, and compressors. Rated for 200-575V AC, 320 A output current, 60/50 Hz, with control voltage 110-240V AC. IP00 enclosure rating
EATON
EATON
Three-phase soft start with bypass, rated 210 A output current, 60/50 Hz, 24V DC control voltage, IP00 enclosure. Used to control acceleration and deceleration of AC induction motors in applications such as pumps, fans, conveyors, and compressors

Lainnya dari EATON

Lihat semua EATON suku cadang
EATON
EATON
Three-phase soft starter with bypass, rated 320 A output current at 60/50 Hz. Operates with 24V DC control voltage and IP00 enclosure. Reduces inrush current and mechanical stress during motor startup, suitable for industrial applications such as pumps, conveyors, and compressors
EATON
EATON
Three-phase soft starter with bypass, rated 32 A output current, 60/50 Hz, and 24V DC control voltage. Enclosure IP20/NEMA 1 for indoor use. Used to control acceleration and deceleration of AC induction motors in applications such as pumps, fans, conveyors, and compressors
EATON
EATON
Three-phase soft starter with bypass, rated 170 A output current at 60/50 Hz. Control voltage 24V DC. IP00 enclosure for open-panel installation. Used to control acceleration and deceleration of AC induction motors in applications such as pumps, fans, conveyors, and compressors
EATON
EATON
Three-phase soft starter with bypass, rated 62 A output current and 110-240V AC control voltage. Enclosed in IP20/NEMA 1 housing, supports 60/50 Hz operation. Used to control motor acceleration in pumps, fans, conveyors, and compressors, reducing mechanical stress and electrical surges
EATON
EATON
Three-phase soft starter with bypass, rated 75 A output current and 24V DC control voltage. Enclosed in IP20/NEMA 1 housing, supports 60/50 Hz operation. Reduces inrush current and mechanical stress during motor startup for applications such as conveyors, pumps, compressors, and fans
EATON
EATON
Three-phase soft start with bypass, rated 410 A output current, 60/50 Hz, IP00 enclosure, and 24V DC control voltage. Used for controlled acceleration and deceleration of induction motors in applications such as pumps, fans, conveyors, and compressors
EATON
EATON
Three-phase soft start with internal bypass for controlling acceleration and deceleration of AC induction motors. Rated 17 A output current, 24V DC control voltage, 60/50 Hz. IP20/NEMA 1 enclosure suitable for indoor industrial applications such as pumps, fans, conveyors, and compressors
EATON
EATON
Three-phase soft start with built-in bypass for controlling acceleration and deceleration of induction motors. Rated 210 A output current at 200-575V AC, 60/50 Hz. Control voltage 110-240V AC. IP00 enclosure. Suitable for pumps, fans, conveyors, and compressors

Ulasan pelanggan

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first