Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type - Thermocouple Meters without Data Output
EXTECHThermocouple Meters without Data Output

EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type

The EXTECH EA11A-NIST is a thermocouple meter without data output, designed for Type K thermocouples and measuring temperatures from -58°F to 1,999°F. It offers Min/Max temperature testing functions with an accuracy…

SKU 3G-OTH-178155

Merek
EXTECH
Item
Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type
Kategori
Thermocouple Meters without Data Output
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

EXTECH
Manufacturer Part Number
EA11A-NIST
Type
For Type K Thermocouple Type, -58°F to 1,999°F
Accuracy
±0.3 % + 2 °F/1 °C
Testing Functions
Min/Max Temperature
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

EXTECH Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The EXTECH EA11A-NIST is a thermocouple meter without data output, designed for Type K thermocouples and measuring temperatures from -58°F to 1,999°F. It offers Min/Max temperature testing functions with an accuracy of ±0.3 % + 2 °F/1 °C.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the EXTECH EA11A-NIST thermocouple thermometer used for?

The EXTECH EA11A-NIST is used for measuring temperatures from -58°F to 1,999°F with Type K thermocouples. It is ideal for industrial maintenance, HVAC diagnostics, and process monitoring where Min/Max temperature tracking is needed. 3G Electric supplies this meter globally.

What are the specifications of the EXTECH EA11A-NIST?

The EXTECH EA11A-NIST is a thermocouple meter for Type K thermocouples, measuring -58°F to 1,999°F. Accuracy is ±0.3 % + 2 °F/1 °C. Testing functions include Min/Max Temperature. It has no data output. 3G Electric sources this EXTECH model for worldwide delivery.

Where to buy the EXTECH EA11A-NIST worldwide?

You can buy the EXTECH EA11A-NIST worldwide through 3G Electric. As a global industrial supplier, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order this Type K thermocouple thermometer with Min/Max functions.

How to select a thermocouple thermometer like the EXTECH EA11A-NIST?

To select a thermocouple thermometer like the EXTECH EA11A-NIST, match the thermocouple type (Type K) to your probe, ensure the temperature range covers your process (-58°F to 1,999°F), and confirm needed functions like Min/Max logging. 3G Electric can advise on compatible probes and accessories.

Digunakan dalam

Aplikasi umum untuk EXTECH
HVAC system diagnostics — EXTECH AN340 vane anemometer for air velocity and humidity measurement
Industrial machinery maintenance — EXTECH 461995 laser tachometer for RPM and surface speed checks
Food and beverage quality testing — EXTECH RF12 analog refractometer for Brix concentration measurement
Refrigerant leak detection — EXTECH RD350 heated diode leak detector for R-513A systems
Environmental monitoring — EXTECH RH490 data logging hygro-thermometer for temperature and humidity logging
Lighting inspection — EXTECH LT300-NIST light meter for illuminance measurement in workspaces

EXTECH Produk

3G Electric memasok EXTECH thermocouple meters without data output. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
EXTECH Thermocouple: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type, 12 Channels (MPN TM500-NIST). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.5 % +5 °F/3 °C (Type R, S); Brand: EXTECH.
EXTECH
EXTECH Thermocouple: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type, 12 Channels (MPN TM500-NIST). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.5 % +5 °F/3 °C (Type R, S); Brand: EXTECH.
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN TM500). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.5 % +5 °F/3 °C (Type R, S); Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN TM500). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.5 % +5 °F/3 °C (Type R, S); Brand: EXTECH.
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN SDL200-NIST). Key specifications — Accuracy: ±0.5 % + 2 °F/1 °C (Type R, S); Brand: EXTECH; Thermocouple Temperature Fahrenheit - Maximum: 752 °F (Type T).
EXTECH
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN SDL200-NIST). Key specifications — Accuracy: ±0.5 % + 2 °F/1 °C (Type R, S); Brand: EXTECH; Thermocouple Temperature Fahrenheit - Maximum: 752 °F (Type T).
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30-NIST). Key specifications — Brand: EXTECH; For RTD Type: Thermocouple; Parameters Measured: Temperature.
EXTECH
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30-NIST). Key specifications — Brand: EXTECH; For RTD Type: Thermocouple; Parameters Measured: Temperature.
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN SDL200). Key specifications — Accuracy: ±0.4 % + 1.8 °F/1 °C (Type J, K, E, T, Pt100 RTD); Brand: EXTECH; Thermocouple Temperature Fahrenheit - Maximum: 752 °F (Type T).
EXTECH
EXTECH Thermocouple Thermometer: For Type E/Type J/Type K/Type R/Type S/Type T Thermocouple Type (MPN SDL200). Key specifications — Accuracy: ±0.4 % + 1.8 °F/1 °C (Type J, K, E, T, Pt100 RTD); Brand: EXTECH; Thermocouple Temperature Fahrenheit - Maximum: 752 °F (Type T).
EXTECH Penetration Temperature Probe: -50°F to 1,000°F /-50°C to 538°C, ±0.2°C/±0.4°F, Type K (MPN TP882). Key specifications — Accuracy: ±0.2 °C; Brand: EXTECH.
EXTECH
EXTECH Penetration Temperature Probe: -50°F to 1,000°F /-50°C to 538°C, ±0.2°C/±0.4°F, Type K (MPN TP882). Key specifications — Accuracy: ±0.2 °C; Brand: EXTECH.

Lainnya dari EXTECH

Lihat semua EXTECH suku cadang
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, 2 Channels, RS-232/SD Card (MPN EA15-NIST). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.05 % + 1.5 °F/0.75 °C (Type J, K, E, T, N); Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, 2 Channels, RS-232/SD Card (MPN EA15-NIST). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.05 % + 1.5 °F/0.75 °C (Type J, K, E, T, N); Brand: EXTECH.
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, For Type K Thermocouple Type, 2 Channels (MPN EA10). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.3 % + 2 °F/1 °C; Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, For Type K Thermocouple Type, 2 Channels (MPN EA10). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.3 % + 2 °F/1 °C; Brand: EXTECH.
EXTECH Thermocouple Thermometer: For Type J/Type K Thermocouple Type, -346°F to 2,501°F (MPN TM100). Key specifications — Testing Functions: Differential Temperature; Accuracy: ±0.15 % + 1 °C; Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: For Type J/Type K Thermocouple Type, -346°F to 2,501°F (MPN TM100). Key specifications — Testing Functions: Differential Temperature; Accuracy: ±0.15 % + 1 °C; Brand: EXTECH.
EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type, -58°F to 1,999°F (MPN EA11A). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.3 % + 2 °F/1 °C; Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type, -58°F to 1,999°F (MPN EA11A). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.3 % + 2 °F/1 °C; Brand: EXTECH.
EXTECH Thermocouple Thermometer: For Type J/Type K Thermocouple Type, -346°F to 2,501°F (MPN TM100-NIST). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.15 % + 1 °C; Brand: EXTECH.
EXTECH
EXTECH Thermocouple Thermometer: For Type J/Type K Thermocouple Type, -346°F to 2,501°F (MPN TM100-NIST). Key specifications — Testing Functions: Min/Max Temperature; Accuracy: ±0.15 % + 1 °C; Brand: EXTECH.
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, 2 Channels, RS-232/SD Card (MPN EA15). Key specifications — Testing Functions: Average Temperature; Accuracy: ±0.05 % + 1.5 °F/0.75 °C (Type J, K, E, T, N); Brand: EXTECH.
EXTECH