Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

EXTECH Pipe Clamp Temperature Probe: -4°F to 450°F /-20°C to 232°C, ±3.6°F/1.8°C - Thermocouples for Surface Applications
EXTECHThermocouples for Surface Applications

EXTECH Pipe Clamp Temperature Probe: -4°F to 450°F /-20°C to 232°C, ±3.6°F/1.8°C

The EXTECH TP400 Pipe Clamp Temperature Probe is a Type K thermocouple for surface applications, featuring a clamp handle design. It offers a temperature range of -4°F to 450°F (-20°C to 232°C) with an accuracy of…

SKU 3G-OTH-178960

Merek
EXTECH
Item
Pipe Clamp Temperature Probe: -4°F to 450°F /-20°C to 232°C, ±3.6°F/1.8°C
Kategori
Thermocouples for Surface Applications
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyur
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Spesifikasi Teknis

EXTECH
Manufacturer Part Number
TP400
Type
±3.6°F/1.8°C, Type K, Clamp Tip
Accuracy
±3.6 °F/1.8 °C
Handle Type
Clamp
Lihat Lembar Spesifikasi Lengkap

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

EXTECH Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

The EXTECH TP400 Pipe Clamp Temperature Probe is a Type K thermocouple for surface applications, featuring a clamp handle design. It offers a temperature range of -4°F to 450°F (-20°C to 232°C) with an accuracy of ±3.6 °F/1.8 °C.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

What is the EXTECH TP400 pipe clamp temperature probe used for?

The EXTECH TP400 is a Type K thermocouple designed for surface temperature measurement on pipes. It is commonly used in HVAC, plumbing, and industrial maintenance to monitor pipe surface temperatures from -20°C to 232°C with ±1.8°C accuracy.

What are the specifications of the EXTECH TP400 temperature probe?

The EXTECH TP400 is a Type K thermocouple with a clamp handle design. It measures temperatures from -20°C to 232°C (-4°F to 450°F) with an accuracy of ±1.8°C (±3.6°F). The manufacturer part number is TP400.

Where to buy the EXTECH TP400 pipe clamp probe worldwide?

3G Electric supplies the EXTECH TP400 pipe clamp temperature probe worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us to source this probe for your application.

How to use the EXTECH TP400 clamp probe for pipe temperature measurement?

To use the EXTECH TP400, attach the clamp tip securely around the pipe surface. Connect the Type K connector to a compatible thermometer or data logger. Ensure good thermal contact for accurate readings. Avoid exceeding the 232°C maximum temperature.

Digunakan dalam

Aplikasi umum untuk EXTECH
HVAC system diagnostics — EXTECH AN340 vane anemometer for air velocity and humidity measurement
Industrial machinery maintenance — EXTECH 461995 laser tachometer for RPM and surface speed checks
Food and beverage quality testing — EXTECH RF12 analog refractometer for Brix concentration measurement
Refrigerant leak detection — EXTECH RD350 heated diode leak detector for R-513A systems
Environmental monitoring — EXTECH RH490 data logging hygro-thermometer for temperature and humidity logging
Lighting inspection — EXTECH LT300-NIST light meter for illuminance measurement in workspaces

EXTECH Produk

3G Electric memasok EXTECH thermocouples for surface applications. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Produk serupa

Dicocokkan berdasarkan spesifikasi dan deskripsi
EXTECH Surface Temperature Probe: -40°F to 842°F /-40°C to 450°C, ±1.5%of Reading ±1.5°C Accuracy (MPN 881616). Key specifications — Brand: EXTECH; Cable Material: Polyurethane; Cable Length: 6 ft; Accuracy: ±1.5 % of Reading ±1.5 °C; Process Mounting Connection: Magnet.
EXTECH
EXTECH Surface Temperature Probe: -40°F to 842°F /-40°C to 450°C, ±1.5%of Reading ±1.5°C Accuracy (MPN 881616). Key specifications — Brand: EXTECH; Cable Material: Polyurethane; Cable Length: 6 ft; Accuracy: ±1.5 % of Reading ±1.5 °C; Process Mounting Connection: Magnet.
EXTECH Penetration Temperature Probe: -50°F to 1,000°F /-50°C to 538°C, ±0.2°C/±0.4°F, Type K (MPN TP882). Key specifications — Accuracy: ±0.2 °C; Brand: EXTECH.
EXTECH
EXTECH Penetration Temperature Probe: -50°F to 1,000°F /-50°C to 538°C, ±0.2°C/±0.4°F, Type K (MPN TP882). Key specifications — Accuracy: ±0.2 °C; Brand: EXTECH.
EXTECH Surface Temperature Probe: -40°F to 932°F /-40°C to 500°C, ±0.2°C/±0.4°F, 5.7 in Probe Lg (MPN 881602). Key specifications — Brand: EXTECH; Accuracy: ±0.4 °F; Handle Type: Straight.
EXTECH
EXTECH Surface Temperature Probe: -40°F to 932°F /-40°C to 500°C, ±0.2°C/±0.4°F, 5.7 in Probe Lg (MPN 881602). Key specifications — Brand: EXTECH; Accuracy: ±0.4 °F; Handle Type: Straight.
EXTECH Immersion Temperature Probe: -40°F to 1,292°F /-40°C to 700°C, Type K, 4 in Probe Lg (MPN 871515). Key specifications — Accuracy: ±2 % of Reading or ±4 °F/2 °C; Brand: EXTECH.
EXTECH
EXTECH Immersion Temperature Probe: -40°F to 1,292°F /-40°C to 700°C, Type K, 4 in Probe Lg (MPN 871515). Key specifications — Accuracy: ±2 % of Reading or ±4 °F/2 °C; Brand: EXTECH.
EXTECH Bead Wire Temperature Probe: -58°F to 1,000°F /-50°C to 538°C, Type K, Rounded Tip (MPN TP875). Key specifications — Brand: EXTECH; Cable Material: Nickel-Chromium ,Nickel-Silicon; Cable Length: 39 in; Accuracy: ±2.5 °C or ±0.75 % of Reading, Whichever is Greater.
EXTECH
EXTECH Bead Wire Temperature Probe: -58°F to 1,000°F /-50°C to 538°C, Type K, Rounded Tip (MPN TP875). Key specifications — Brand: EXTECH; Cable Material: Nickel-Chromium ,Nickel-Silicon; Cable Length: 39 in; Accuracy: ±2.5 °C or ±0.75 % of Reading, Whichever is Greater.
EXTECH Bead Wire Temperature Probe: -22°F to 572°F /-30°C to 300°C, ±2.5°C, Type K, Rounded Tip (MPN TP873). Key specifications — Brand: EXTECH; Cable Material: Fiberglass; Cable Length: 3 ft; Accuracy: ±2.5 °C.
EXTECH
EXTECH Bead Wire Temperature Probe: -22°F to 572°F /-30°C to 300°C, ±2.5°C, Type K, Rounded Tip (MPN TP873). Key specifications — Brand: EXTECH; Cable Material: Fiberglass; Cable Length: 3 ft; Accuracy: ±2.5 °C.

Lainnya dari EXTECH

Lihat semua EXTECH suku cadang
EXTECH Pipe Clamp Temperature Probe: -4°F to 200°F /-20°C to 93°C, ±5%Full Scale Accuracy, Type K (MPN TP200). Key specifications — Brand: EXTECH; Accuracy: ±5 % Full Scale; Handle Type: Clamp.
EXTECH
EXTECH Pipe Clamp Temperature Probe: -4°F to 200°F /-20°C to 93°C, ±5%Full Scale Accuracy, Type K (MPN TP200). Key specifications — Brand: EXTECH; Accuracy: ±5 % Full Scale; Handle Type: Clamp.
EXTECH Bead Wire Temperature Probe: -22°F to 572°F /-30°C to 300°C, ±2.5°C, Type K, Rounded Tip (MPN TP873-5M). Key specifications — Brand: EXTECH; Cable Material: Fiberglass; Cable Length: 16.4 ft; Accuracy: ±2.5 °C.
EXTECH
EXTECH Bead Wire Temperature Probe: -22°F to 572°F /-30°C to 300°C, ±2.5°C, Type K, Rounded Tip (MPN TP873-5M). Key specifications — Brand: EXTECH; Cable Material: Fiberglass; Cable Length: 16.4 ft; Accuracy: ±2.5 °C.