Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

Pencegah Aliran Balik Zona Tekanan Rendah FEBCO: 825YA, Dengan Sensor Beku, Perunggu - Febco RPZ Backflow Preventers
FEBCOFebco RPZ Backflow Preventers

Pencegah Aliran Balik Zona Tekanan Rendah FEBCO: 825YA, Dengan Sensor Beku, Perunggu

FEBCO Reduced Pressure Zone Backflow Preventer 825YA adalah perangkat pencegah aliran balik (backflow) tipe RPZ yang dirancang untuk melindungi sistem air bersih dari kontaminasi. Produk ini terbuat dari material…

SKU 3G-OTH-442040

Juga terdaftar sebagai: 825YA112 · 825 YA 1 1 2 · 825-YA-1-1-2

Merek
FEBCO
Item
Pencegah Aliran Balik Zona Tekanan Rendah FEBCO: 825YA, Dengan Sensor Beku, Perunggu
Kategori
Febco RPZ Backflow Preventers
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FEBCO
Manufacturer Part Number
825 YA 1-1/2
Type
With Freeze Sensor, Bronze, FNPT, Buna-N
Connection Type
FNPT
Shut-Off Valve Type
Ball Valve

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FEBCO Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FEBCO Reduced Pressure Zone Backflow Preventer 825YA adalah perangkat pencegah aliran balik (backflow) tipe RPZ yang dirancang untuk melindungi sistem air bersih dari kontaminasi. Produk ini terbuat dari material bronze dengan koneksi FNPT, dilengkapi sensor beku (freeze sensor) dan katup penutup tipe ball valve. Komponen seal menggunakan Buna-N, dan model ini memiliki Manufacturer Part Number 825 YA 1-1/2. Cocok digunakan pada instalasi perpipaan industri dan komersial di Indonesia yang memerlukan perlindungan backflow sesuai standar.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa fungsi FEBCO Reduced Pressure Zone Backflow Preventer 825YA?

FEBCO 825YA berfungsi sebagai pencegah aliran balik (backflow) pada sistem perpipaan air bersih. Dengan tipe RPZ (Reduced Pressure Zone), alat ini memastikan air yang terkontaminasi tidak kembali ke sumber air utama. Dilengkapi sensor beku untuk perlindungan tambahan di kondisi dingin.

Apa spesifikasi teknis FEBCO 825YA 1-1/2?

Spesifikasi FEBCO 825YA meliputi material bronze, koneksi FNPT, katup penutup tipe ball valve, seal Buna-N, dan dilengkapi freeze sensor. Manufacturer Part Number adalah 825 YA 1-1/2. Produk ini dirancang untuk aplikasi backflow prevention pada sistem perpipaan.

Di mana beli FEBCO 825YA di Indonesia?

Anda dapat membeli FEBCO 825YA melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan kepabeanan sehingga Anda tidak perlu repot mengurus impor. Hubungi kami untuk minta penawaran.

Apa perbedaan FEBCO 825YA dengan tipe RPZ lainnya?

FEBCO 825YA memiliki fitur freeze sensor yang tidak selalu ada pada tipe RPZ lain. Material bronze dan koneksi FNPT membuatnya tahan korosi dan mudah dipasang pada sistem perpipaan. Katup ball valve memudahkan pengoperasian shut-off. Pastikan memilih sesuai kebutuhan tekanan dan ukuran pipa Anda.

Digunakan dalam

Aplikasi umum untuk FEBCO
Commercial water supply — FEBCO 825YA RPZ backflow preventer installed at building mains to prevent cross-connection contamination.
Irrigation systems — FEBCO 825Y double check valve assembly used in landscape irrigation to protect potable water lines.
Industrial process water — FEBCO LF825YA lead-free backflow preventer used in food processing plants to comply with health codes.
Municipal water treatment — FEBCO 825YA with flood detection sensor installed at treatment plant outlets for early leak detection.
Fire protection systems — FEBCO RPZ backflow preventer used in fire sprinkler systems to prevent backflow from non-potable sources.
HVAC cooling towers — FEBCO 825Y backflow preventer installed on makeup water lines to cooling towers to prevent chemical backflow.

FEBCO Produk

3G Electric memasok FEBCO febco rpz backflow preventers. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Bronze reduced pressure zone backflow preventer with 1 in FNPT connections. Includes an integral strainer and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow contamination of potable water supplies
Watts
Bronze reduced pressure zone backflow preventer with 1 in FNPT connections. Includes an integral strainer and ball valve shut-off. Used in commercial and industrial plumbing systems to prevent backflow contamination of potable water supplies
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with 1-1/4 inch female NPT connections and ball valve shut-offs. Rated for operating temperatures from 33°F to 180°F. Used to protect potable water supplies from cross-connection contamination in commercial and industrial plumbing systems
Watts
Reduced pressure zone backflow preventer in standard configuration. Constructed of bronze with 1-1/4 inch female NPT connections and ball valve shut-offs. Rated for operating temperatures from 33°F to 180°F. Used to protect potable water supplies from cross-connection contamination in commercial and industrial plumbing systems
Reduced pressure zone backflow preventer for protecting potable water supplies from cross-connection contamination. Bronze body with 1/2-inch female NPT connections and ball valve shut-off. Rated for temperatures from 33°F to 180°F. Suitable for continuous pressure applications on water service lines, boiler feed lines, and irrigation systems
Watts
Reduced pressure zone backflow preventer for protecting potable water supplies from cross-connection contamination. Bronze body with 1/2-inch female NPT connections and ball valve shut-off. Rated for temperatures from 33°F to 180°F. Suitable for continuous pressure applications on water service lines, boiler feed lines, and irrigation systems
Repair kit for Watts backflow preventers, includes two O-rings. Compatible with Febco Backflow series models 1-1/2-2 825Y/825YA and valve sizes 1-1/2 in to 2 in. Used to replace worn seals in relief valves for backflow prevention systems
FEBCO
Repair kit for Watts backflow preventers, includes two O-rings. Compatible with Febco Backflow series models 1-1/2-2 825Y/825YA and valve sizes 1-1/2 in to 2 in. Used to replace worn seals in relief valves for backflow prevention systems
Reduced pressure zone backflow preventer with integral strainer and ball valve shut-off. Constructed with bronze body and plastic components, 2-inch FNPT connections. Temperature range 33°F to 180°F. Used in commercial and industrial plumbing systems to protect potable water from cross-connection contamination under continuous pressure and high-hazard conditions
Watts
Reduced pressure zone backflow preventer with integral strainer and ball valve shut-off. Constructed with bronze body and plastic components, 2-inch FNPT connections. Temperature range 33°F to 180°F. Used in commercial and industrial plumbing systems to protect potable water from cross-connection contamination under continuous pressure and high-hazard conditions
Reduced pressure zone backflow preventer in bronze with 1-1/2 inch FNPT connections. Includes integral strainer and ball valve shut-off. Rated for continuous pressure service in commercial and industrial plumbing systems to prevent cross-connection contamination of potable water supplies
Watts
Reduced pressure zone backflow preventer in bronze with 1-1/2 inch FNPT connections. Includes integral strainer and ball valve shut-off. Rated for continuous pressure service in commercial and industrial plumbing systems to prevent cross-connection contamination of potable water supplies

Lainnya dari FEBCO

Lihat semua FEBCO suku cadang
This FEBCO reduced pressure zone backflow preventer is designed to protect potable water supplies from cross-connection contamination. It includes an integrated flood detection sensor and strainer for early leak warning and debris filtration. The flange connection type suits commercial and industrial applications such as manufacturing, HVAC, and process water lines
FEBCO
This FEBCO reduced pressure zone backflow preventer is designed to protect potable water supplies from cross-connection contamination. It includes an integrated flood detection sensor and strainer for early leak warning and debris filtration. The flange connection type suits commercial and industrial applications such as manufacturing, HVAC, and process water lines
Reduced pressure zone backflow preventer with ball valve shut-off and FNPT connection. Prevents backflow of contaminated water into potable water supplies. Suitable for commercial and industrial plumbing systems to protect against cross-connections and back-siphonage
FEBCO
Reduced pressure zone backflow preventer with ball valve shut-off and FNPT connection. Prevents backflow of contaminated water into potable water supplies. Suitable for commercial and industrial plumbing systems to protect against cross-connections and back-siphonage
Bronze reduced pressure zone backflow preventer with 2-inch FNPT connections and ball valve shut-offs. Includes freeze sensor for cold-weather installations. Used in commercial and industrial plumbing systems to prevent backflow of contaminated water into potable supplies
FEBCO
Bronze reduced pressure zone backflow preventer with 2-inch FNPT connections and ball valve shut-offs. Includes freeze sensor for cold-weather installations. Used in commercial and industrial plumbing systems to prevent backflow of contaminated water into potable supplies
Reduced pressure zone backflow preventer with FNPT connections and ball valve shut-off. Protects potable water supplies by preventing reverse flow in cross-connection situations. Suitable for commercial and industrial plumbing systems, including irrigation and fire sprinkler lines
FEBCO
Reduced pressure zone backflow preventer with FNPT connections and ball valve shut-off. Protects potable water supplies by preventing reverse flow in cross-connection situations. Suitable for commercial and industrial plumbing systems, including irrigation and fire sprinkler lines
Reduced pressure zone backflow preventer with flange connections, flood detection sensor, and integrated strainer. Used to prevent backflow of contaminated water into potable water supplies in commercial, industrial, and municipal systems
FEBCO
Reduced pressure zone backflow preventer with flange connections, flood detection sensor, and integrated strainer. Used to prevent backflow of contaminated water into potable water supplies in commercial, industrial, and municipal systems
Flange-connected RPZ backflow preventer with integrated flood detection sensor and strainer. Designed to protect potable water supplies from cross-connection contamination in high-hazard conditions. Suitable for commercial, industrial, and municipal water systems
FEBCO
Flange-connected RPZ backflow preventer with integrated flood detection sensor and strainer. Designed to protect potable water supplies from cross-connection contamination in high-hazard conditions. Suitable for commercial, industrial, and municipal water systems
Reduced pressure zone backflow preventer with integrated flood detection sensor and strainer. Flange connection type. Used in commercial, industrial, and municipal water systems to prevent backflow contamination of potable water supplies
FEBCO
Reduced pressure zone backflow preventer with integrated flood detection sensor and strainer. Flange connection type. Used in commercial, industrial, and municipal water systems to prevent backflow contamination of potable water supplies