Konten Lembar Data
[{"filename":"NEX-6101-NX6100_Series_Integrated_Burner_Controller_English_2025-21-02.pdf","text":"NEX-6101\n February 21, 2025\n\n\n NX6100\n Integrated Burner Controller\n\n\nCommissioning Manual\n\f NX6100 Burner Controller\n\n\n\n\n DESCRIPTION\n\n The Fireye NEXUS NX6100 Integrated Controller is a microprocessor based, Flame Safeguard and Parallel\n Positioning Combustion Controller built into one compact, user configurable package. The system consists of\n the Controller, Display, Temperature / Pressure Sensors, Servomotors, and optional ComFire2 Software.\n\n The Flame Safeguard portion of the control package provides burner sequencing including safe start check, proof\n of main valve closure, selectable main gas safety proving sequence, supervised pre-purge, low fire-starting\n position, pilot and main trials for ignition, main flame supervision, and post purge. Safety event timings are\n provided to meet North American and CE Standards. Time proven Fireye Flame Scanners and amplification\n circuits using UV, UV-Self Check, and Infrared sensors, provide fast reliable scanning of most commonly burned\n fuels in addition Fireye Self Checking CANbus sensor may be used for simplified wiring. For exotic fuels and\n applications, the NX6100 is also compatible with Fireye Phoenix and Insight Integrated Flame Scanners. Seven\n low voltage and two-line voltage user defined auxiliary inputs provide supervision of safety critical and non-safety\n critical inputs. A large menu of alarm messages provides enhanced diagnostics.\n\n Control of up to four profiles using an independent Servomotor for each controlled element allows precise\n positioning, accurate to 0.1o, of the fuel and air metering devices over the burner’s firing range. Each profile can\n be defined to include up to 10 servomotors. Profiles can be configured to share common fuel servomotors or as\n independent (one profile per fuel) and are not limited by fuel. Up to 24 positions per profile including: Closed,\n Purge, Ignition (Preferred Start), Low Fire and an additional 20 intermediate points from low to high fire. Each\n individual servomotor’s position and speed are verified, and lockout will occur should either of these parameters\n be exceeded. All servomotors are controlled via secure CANbus communications link.\n\n Modulation control is provided via the pressure/temperature sensor’s input. The Fireye NX1025, NX1030 or\n NX1040 sensors provide checking circuits for fail safe operation. Two PID setpoints are available for the chosen\n modulation input, selectable up to two decimal points. Track modulation is available for those applications\n requiring less precise control.\n\n The NX6220 and NX6330 Twelve-Key Display allows commissioning and current status of the system through\n the use of its tactile membrane keypad. Multi-function keys allow the commissioning to engineer the ability to\n access the various Ratio Modes and Option Select menus. The four-line OLED Display clearly illuminates the\n Control Variable, Firing Mode, Fuel Selected and Hours Run. It further allows the Boiler Operator access to the\n Auto/Manual selector, Motor Data (servo positions) and other operational parameters such as System Sequence\n Position, Valve Proving Sequence Status, Gas Pressure, Flame Signal, Modulation Rate and Setpoint, as\n necessary.\n\n Multiple Boiler Sequencing is accomplished through an RS485 Communications bus using ComFire2 software.\n Lead/Lag and Standby set points for up to four (4) boilers can be configured.\n\n When replacing control with firmware version 1.307 with firmware version 1.4XX it is required that obsolete\n displays NX610/NX6110 be removed and replaced with a NX6220/NX6330 this is not necessary if a NXTSDXXX\n touchscreen is present.\n\n\n\n\n1 NX6100 Fireye - Introduction V1pt4D Commissioning Manual version 1.4\n© 2025 Fireye\n\f Introduction\n\n Part No Description\n INTERGRATED PARALLEL POSTIONING CONTROL\n NX6100 Standalone parallel positioning controller, with up to ten (10) selectable\n function CANbus servos for custom applications.\n 3G-OTH-02768 VFD daughterboard with two VFD channels, one analog output, two encoder\n inputs, two programmable relays, isolated RS485 – Modbus RTU.\n NXMBDB MODbus RTU interface cards for NX6100/PPC6000. Networks up to 15\n control – one card per control.\n NX8WC-HUB Passive CANbus Hub with Screw terminals - Portrait profile.\n DISPLAY MODULES FOR NX6100\n NX6110 Obsolete use NX6220 or NX6330.\n NX6220 12 key CANbus Organic LED (OLED) display for NX6300 with\n upload/download of NX6300 data and three programmable relays. USB port for\n updates and future functions TBD.\n NX6330 12 key CANbus Organic LED (OLED) display for NX6300 with\n upload/download of NX6300 data and three programmable relays. USB port for\n updates and future functions TBD. Also mounted with RJ45 Ethernet port for\n BAS integration. Onboard Modbus TC/PIP and BACnet protocols.\n\n NXTSD007 7” Touchscreen Display with upload/download, full commissioning, data log,\n internet connection, four programmable relays. Onboard Modbus TC/PIP and\n BACnet protocols.\n 10.4” Touchscreen Display with upload/download, full commissioning, data\n log, internet connection, four programmable relays. Onboard Modbus TC/PIP\n NXTSD104\n and BACnet protocols.\n SERVO MOTORS For NX6100\n NXC04 4 wire CANbus Servomotor, 3 ft lbs. torque, 4 Nm, 50/60 Hz, 24 VAC.\n NXC12 4 wire CANbus Servomotor, 9 ft lbs. torque, 12 Nm, 50/60 Hz, 24 VAC.\n NXC20 4 wire CANbus Servomotor, 14.75 ft lbs. torque, 20 Nm, 50/60 Hz, 24 VAC.\n 35-321 PG9 male to ½” NPSM female adapter for NXC04, NXC12\n 35-322 PG11 male to ½” NPSM female adapter for NXC20\n 35-372 M20 male to ½” NPSM female adapter for NXC40\n Type 2 O2 PROBES AND EXPANSION MODULE FOR NX6100\n NXO2TRIM CANbus O2 interface module with Fireye and generic (4-20mA) probe inputs.\n\n NX-CAB-SET Interconnecting Cable from O2 probe to controller 33ft (10 m.) ONLY\n NXPK224455 O2 probe assembly (for flues 300mm to 1000mm). Includes NXIATS CANbus\n ambient temperature sensor, flange kit.\n NXPK224456 O2 probe assembly (for flues 600mm to 2000mm). Includes NXIATS CANbus\n ambient temperature sensor, flange kit.\n NXPK224457 O2 probe assembly (for flues 1200mm to 4000mm). Includes NXIATS CANbus\n ambient temperature sensor, flange kit.\n NX6083-1 Replacement O2 probe for NXPK224455. Does not include mounting flange,\n ambient air sensor, or transformer.\n NX6083-2 Replacement O2 probe for NXPK224456. Does not include mounting flange,\n ambient air sensor, or transformer.\n NX6083-3 Replacement O2 probe for NXPK224457. Does not include mounting flange,\n ambient air sensor, or transformer.\n NXIATS NX6300 CANbus Inlet (ambient) Air Temperature Sensor -29C to 60C (-20F\n to 140F)\n\n\n\n1 NX6100 Fireye - Introduction V1pt4D Commissioning Manual version 1.4\n© 2025 Fireye\n\f NON-SELF TEST PRESSURE SENSORS FOR NX6100\n PXMS-15K Steam Pressure Sensor: 0 - 15 PSI, 0 - 1 bar, 4-20mA output, 1/2\" NPT, non-\n self-check.\n PXMS-200K Steam Pressure Sensor: 0 - 200 PSI, 0 - 14 bar, 4-20mA output, 1/2\" NPT, non-\n self-check.\n PXMS-300K Steam Pressure Sensor: 0 - 300 PSI, 0 - 21 bar, 4-20mA output, 1/2\" NPT, non-\n self-check.\n Pressure transducer, 0-15 psi (0-1030 mb), 4-20 mA output linear with\n BLPS-15 pressure. ¼\" NPT mounting. Screw terminal connections and conduit adapter\n cover.\n Pressure transducer, 0-30 psi (0-2070 mb), 4-20 mA output linear with\n BLPS-30 pressure. ¼\" NPT mounting. Screw terminal connections and conduit adapter\n cover.\n\n Pressure transducer, 0-200 psi (0-13.8 Bar), 4-20 mA output linear with\n BLPS-200 pressure. ¼\" NPT mounting. Screw terminal connections and conduit adapter\n cover.\n Pressure transducer, 0-300 psi (0-20.7 Bar), 4-20 mA output linear with\n BLPS-300 pressure. ¼\" NPT mounting. Screw terminal connections and conduit adapter\n cover.\n\n NON-SELF TEST TEMPERATURE SENSORS\n TS350 (-2), (-4), (-8) Temperature Sensor, Range 32oF-350oF (0-176oC), 4-20mA linear output,\n includes 1/2 - 14 NPT well. See bulletin BLZPTS-1 for complete description.\n\n TS752 (-2), (-4), (-8) Temperature Sensor, Range 32oF-752oF (0-400oC), 4-20mA linear output,\n includes 1/2 - 14 NPT well. See bulletin BLZPTS-1 for complete description.\n\n SELF-TEST CANbus SENSORS\n NX6043-1 CANbus Gas pressure sensor 600 mbar (8.7psi) span and NPT process\n connection.\n NX6043-2 CANbus Gas pressure sensor 600 mbar (8.7psi) span and G 1/4 P process\n connection.\n NX6044-1 CANbus Pressure sensor 4 bar (58 psi) span and NPT process connection.\n\n NX6044-2 CANbus Pressure sensor 4 bar (58 psi) span and G 1/4 P process connection.\n\n NX6045-1 CANbus Pressure sensor 25 bar (363 psi) span and NPT process connection.\n\n NX6045-2 CANbus Pressure sensor 25 bar (363 psi) span and G 1/4 P process\n connection.\n CANbus Self Checking FLAME SCANNERS\n NX6094 CANbus self-checking Flame Scanner for radial view - includes mounting\n clamp LA223883.\n NX6095 CANbus self-checking Flame Scanner for Axial view.\n NX224763 6094 UV Tube Replacement Kit\n NX224762 6095 UV Tube Replacement Kit\n NX224760-15 5m (15') CANbus quick disconnect connection cable for Pressure sensors.\n and scanners.\n\n\n\n\n1 NX6100 Fireye - Introduction V1pt4D Commissioning Manual version 1.4\n© 2025 Fireye\n\f Fireye Flame Scanners\n 45UV5-1009 UV self-check scanner, 1\" NPT, 102 - 264 VAC shutter.\n UV1A3 UV scanner, 1/2\" NPT connector, 3 ft. cable rated for Tray Cable -\n Exposed Run (TC-ER).\n UV8A UV scanner, 1/2\" NPT connector, 90-degree angle head, 6 ft. cable.\n 48PT2-1003 Infrared scanner, 8', straight head\n 48PT2-9003 Infrared scanner, 8', 90-degree head\n 85XXX-XWR Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919\n mounting flange.\n 95XXXX-X InSight I Flame Scanner. Use 60-2692 1” NPT Mounting Flange\n 59-497-020C-WR Factory wired cable assembly with straight connector and flexible conduit\n adapter B1266- 20…