Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FLUKE 9102S-156 Single-Block Drywell Calibrator - Single-Block Drywell Calibrators with Adjustable Setpoints
FLUKESingle-Block Drywell Calibrators with Adjustable Setpoints

FLUKE 9102S-156 Single-Block Drywell Calibrator

FLUKE Drywall Temperature Calibrator tipe 9102S-156 adalah single-block drywell calibrator dengan adjustable setpoints yang dirancang untuk kalibrasi suhu presisi di lingkungan industri. Alat ini mencakup rentang…

SKU 3G-OTH-178558

Juga terdaftar sebagai: 9102S156 · 9102S 156

Merek
FLUKE
Item
9102S-156 Single-Block Drywell Calibrator
Kategori
Single-Block Drywell Calibrators with Adjustable Setpoints
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FLUKE
Manufacturer Part Number
9102S-156
Type
14°F to 252°F /-10°C to 122°C
Stability
+/- 0.05°C
For Stem Diameter
0.1875 in

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FLUKE Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FLUKE Drywall Temperature Calibrator tipe 9102S-156 adalah single-block drywell calibrator dengan adjustable setpoints yang dirancang untuk kalibrasi suhu presisi di lingkungan industri. Alat ini mencakup rentang suhu dari 14°F hingga 252°F (-10°C hingga 122°C) dengan stabilitas ±0.05°C, dan dapat digunakan untuk stem diameter hingga 0.1875 in. Cocok untuk aplikasi kalibrasi di pabrik kelapa sawit, semen, atau industri pengolahan makanan dan minuman di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FLUKE 9102S-156 Drywall Temperature Calibrator?

FLUKE 9102S-156 adalah single-block drywell calibrator dengan rentang suhu 14°F hingga 252°F (-10°C hingga 122°C), stabilitas ±0.05°C, dan dapat menerima stem diameter hingga 0.1875 in. Alat ini memiliki adjustable setpoints untuk kalibrasi presisi.

Untuk apa FLUKE Drywall Temperature Calibrator digunakan?

FLUKE Drywall Temperature Calibrator digunakan untuk mengkalibrasi sensor suhu seperti termokopel atau RTD di lingkungan industri. Dengan rentang suhu -10°C hingga 122°C dan stabilitas ±0.05°C, alat ini ideal untuk memastikan akurasi pengukuran suhu di pabrik, laboratorium, atau fasilitas produksi.

Bagaimana cara memilih drywell calibrator yang tepat?

Pilih drywell calibrator berdasarkan rentang suhu yang dibutuhkan, stabilitas, dan ukuran stem diameter sensor Anda. FLUKE 9102S-156 menawarkan rentang -10°C hingga 122°C dengan stabilitas ±0.05°C dan stem diameter 0.1875 in, cocok untuk kalibrasi sensor berdiameter kecil.

Di mana beli FLUKE 9102S-156 di Indonesia?

Anda dapat membeli FLUKE 9102S-156 Drywall Temperature Calibrator melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Digunakan dalam

Aplikasi umum untuk FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Produk

3G Electric memasok FLUKE single-block drywell calibrators with adjustable setpoints. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dual function immersion controller for hydronic heating systems, combining circulator, high limit, and low limit functions. Temperature range 100°F to 240°F with adjustable differential from 5°F to 30°F. Includes auto/manual switch. Designed for horizontal mounting
HONEYWELL HOME
Dual function immersion controller for hydronic heating systems, combining circulator, high limit, and low limit functions. Temperature range 100°F to 240°F with adjustable differential from 5°F to 30°F. Includes auto/manual switch. Designed for horizontal mounting
This dual function immersion controller serves as both a high limit and low limit device for hydronic heating systems. It features a temperature range of 130°F minimum to 240°F maximum, with an adjustable low-limit differential of 10°F to 25°F. The controller includes an auto/manual switch and is designed for vertical mounting orientation
HONEYWELL HOME
This dual function immersion controller serves as both a high limit and low limit device for hydronic heating systems. It features a temperature range of 130°F minimum to 240°F maximum, with an adjustable low-limit differential of 10°F to 25°F. The controller includes an auto/manual switch and is designed for vertical mounting orientation
Single-function immersion controller for high-limit application in hydronic heating systems. Features a 180°F minimum and 240°F maximum temperature range with a fixed 15°F differential. Vertical mounting orientation with auto/manual switch included. Supports line volt/low volt switching with 6 switches
HONEYWELL HOME
Single-function immersion controller for high-limit application in hydronic heating systems. Features a 180°F minimum and 240°F maximum temperature range with a fixed 15°F differential. Vertical mounting orientation with auto/manual switch included. Supports line volt/low volt switching with 6 switches
Single-function immersion controller for low-limit applications in heating systems. Features a 100°F to 240°F temperature range with adjustable differential from 5°F to 30°F. Includes one millivolt switch and an auto/manual switch. Designed for horizontal mounting
HONEYWELL HOME
Single-function immersion controller for low-limit applications in heating systems. Features a 100°F to 240°F temperature range with adjustable differential from 5°F to 30°F. Includes one millivolt switch and an auto/manual switch. Designed for horizontal mounting
This immersion controller is designed for low-limit applications in heating systems. It monitors fluid temperature with a range of 100°F to 240°F and features an adjustable differential from 5°F to 30°F. The controller includes an auto/manual switch and is intended for vertical mounting orientation
HONEYWELL HOME
This immersion controller is designed for low-limit applications in heating systems. It monitors fluid temperature with a range of 100°F to 240°F and features an adjustable differential from 5°F to 30°F. The controller includes an auto/manual switch and is intended for vertical mounting orientation
This single-function immersion controller is configured as a high-limit safety device for hydronic heating systems. It features a fixed 15°F differential temperature, a vertical mounting orientation, and an included auto/manual switch. The controller operates on low voltage and has a temperature range of 180°F to 240°F
HONEYWELL HOME
This single-function immersion controller is configured as a high-limit safety device for hydronic heating systems. It features a fixed 15°F differential temperature, a vertical mounting orientation, and an included auto/manual switch. The controller operates on low voltage and has a temperature range of 180°F to 240°F

Lainnya dari FLUKE

Lihat semua FLUKE suku cadang
Single-block drywell calibrator with adjustable setpoints for temperature sensor verification. Temperature range 95°F to 707°F (35°C to 375°C) with stability ±0.07°C at 50°C. Accepts probes with stem diameter 0.125 in. Used for calibrating thermocouples, RTDs, and other temperature probes in industrial, HVAC, and laboratory settings
FLUKE
Single-block drywell calibrator with adjustable setpoints for temperature sensor verification. Temperature range 95°F to 707°F (35°C to 375°C) with stability ±0.07°C at 50°C. Accepts probes with stem diameter 0.125 in. Used for calibrating thermocouples, RTDs, and other temperature probes in industrial, HVAC, and laboratory settings
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
FLUKE
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range 95°F to 662°F / 35°C to 350°C. Stability ±0.05°C at 350°C. Accommodates two stem diameters of 3/16 in. Suitable for industrial process control, HVAC, and quality assurance applications
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range 95°F to 662°F / 35°C to 350°C. Stability ±0.05°C at 350°C. Accommodates two stem diameters of 3/16 in. Suitable for industrial process control, HVAC, and quality assurance applications
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Covers 95°F to 707°F (35°C to 375°C) with stability of ±0.1°C at 100°C. Accepts probes with stem diameter up to 0.375 inches. Suitable for field or shop calibration of thermocouples, RTDs, and thermistors
FLUKE
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Covers 95°F to 707°F (35°C to 375°C) with stability of ±0.1°C at 100°C. Accepts probes with stem diameter up to 0.375 inches. Suitable for field or shop calibration of thermocouples, RTDs, and thermistors
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Temperature range -25°C to 140°C with stability ±0.02°C at -25°C. Accepts two probes with 4 mm stem diameter. Suitable for field calibration of thermocouples, RTDs, and thermistors in industrial and laboratory settings
FLUKE
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Temperature range -25°C to 140°C with stability ±0.02°C at -25°C. Accepts two probes with 4 mm stem diameter. Suitable for field calibration of thermocouples, RTDs, and thermistors in industrial and laboratory settings