Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FLUKE 9190A-DW-156 Ultra-High & Low Temperature Field Metrology Well - Ultra-High & Low Temperature Field Metrology Wells
FLUKEUltra-High & Low Temperature Field Metrology Wells

FLUKE 9190A-DW-156 Ultra-High & Low Temperature Field Metrology Well

FLUKE Drywell 9190A-DW-156 adalah Ultra-High & Low Temperature Field Metrology Wells yang dirancang untuk kalibrasi suhu di lapangan dengan rentang -139°F hingga 284°F / -95°C hingga 140°C. Alat ini menawarkan…

SKU 3G-OTH-177134

Juga terdaftar sebagai: 9190ADW156 · 9190A DW 156

Merek
FLUKE
Item
9190A-DW-156 Ultra-High & Low Temperature Field Metrology Well
Kategori
Ultra-High & Low Temperature Field Metrology Wells
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FLUKE
Manufacturer Part Number
9190A-DW-156
Type
-139°F to 284°F /-95°C to 140°C, +/-0.2°C
Stability
+/-0.015°C
For Stem Diameter
6 mm

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FLUKE Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FLUKE Drywell 9190A-DW-156 adalah Ultra-High & Low Temperature Field Metrology Wells yang dirancang untuk kalibrasi suhu di lapangan dengan rentang -139°F hingga 284°F / -95°C hingga 140°C. Alat ini menawarkan stabilitas +/-0.015°C dan akurasi +/-0.2°C, serta dapat digunakan untuk stem diameter 6 mm. Cocok untuk teknisi kalibrasi yang membutuhkan referensi suhu presisi tinggi di lingkungan industri.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FLUKE Drywell 9190A-DW-156?

FLUKE Drywell 9190A-DW-156 memiliki rentang suhu -139°F hingga 284°F / -95°C hingga 140°C, stabilitas +/-0.015°C, akurasi +/-0.2°C, dan dirancang untuk stem diameter 6 mm. Produk ini ideal untuk kalibrasi suhu lapangan.

Untuk apa FLUKE Drywell digunakan?

FLUKE Drywell 9190A-DW-156 digunakan sebagai referensi suhu portabel untuk mengkalibrasi sensor suhu seperti termokopel dan RTD di lapangan. Rentang suhu -95°C hingga 140°C membuatnya cocok untuk aplikasi industri yang memerlukan akurasi tinggi.

Di mana beli FLUKE Drywell 9190A-DW-156 di Indonesia?

Anda dapat membeli FLUKE Drywell 9190A-DW-156 melalui 3G Electric, distributor resmi yang memasok dan mengirimkan produk ini ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan pengiriman lancar ke lokasi Anda.

Bagaimana cara memilih FLUKE Drywell yang tepat?

Pilih FLUKE Drywell berdasarkan rentang suhu yang dibutuhkan. Model 9190A-DW-156 mencakup -95°C hingga 140°C dengan stabilitas +/-0.015°C dan akurasi +/-0.2°C. Pastikan stem diameter sensor Anda 6 mm agar sesuai dengan well.

Digunakan dalam

Aplikasi umum untuk FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Produk

3G Electric memasok FLUKE ultra-high & low temperature field metrology wells. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Pembakar & Pembakaran Pompa & Kompresor Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
Temperature calibration well covering -95°C to 140°C (-139°F to 284°F) with ±0.2°C accuracy and ±0.015°C stability. Accepts two 4 mm diameter sensor stems. Includes process connections for field calibration of temperature sensors in industrial maintenance and quality assurance applications
FLUKE
Temperature calibration well covering -95°C to 140°C (-139°F to 284°F) with ±0.2°C accuracy and ±0.015°C stability. Accepts two 4 mm diameter sensor stems. Includes process connections for field calibration of temperature sensors in industrial maintenance and quality assurance applications
This field metrology well covers -95°C to 140°C with stability of ±0.015°C and accommodates 6 mm stem diameter probes. It is used for on-site calibration of temperature sensors in industrial environments requiring precise temperature references
FLUKE
This field metrology well covers -95°C to 140°C with stability of ±0.015°C and accommodates 6 mm stem diameter probes. It is used for on-site calibration of temperature sensors in industrial environments requiring precise temperature references
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with accuracy ±0.2°C and stability ±0.015°C. Accepts probes with 3 mm stem diameter. Includes process connections for field use
FLUKE
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with accuracy ±0.2°C and stability ±0.015°C. Accepts probes with 3 mm stem diameter. Includes process connections for field use
Field metrology well covering -95°C to 140°C with ±0.2°C accuracy and ±0.015°C stability. Accepts probes with 6 mm stem diameter. Used for on-site calibration of temperature sensors in industrial process applications
FLUKE
Field metrology well covering -95°C to 140°C with ±0.2°C accuracy and ±0.015°C stability. Accepts probes with 6 mm stem diameter. Used for on-site calibration of temperature sensors in industrial process applications
Field metrology well covering -95°C to 140°C with ±0.2°C accuracy and ±0.015°C stability. Accommodates six 1/4-inch diameter stems. Includes process connections for in-situ calibration of temperature sensors in industrial and laboratory environments
FLUKE
Field metrology well covering -95°C to 140°C with ±0.2°C accuracy and ±0.015°C stability. Accommodates six 1/4-inch diameter stems. Includes process connections for in-situ calibration of temperature sensors in industrial and laboratory environments
This field metrology well covers a temperature range of -95°C to 140°C with stability of ±0.015°C and accuracy of ±0.2°C. It accommodates two probes with 3/16 in stem diameter and includes process connections for calibration of temperature sensors in industrial applications
FLUKE
This field metrology well covers a temperature range of -95°C to 140°C with stability of ±0.015°C and accuracy of ±0.2°C. It accommodates two probes with 3/16 in stem diameter and includes process connections for calibration of temperature sensors in industrial applications

Lainnya dari FLUKE

Lihat semua FLUKE suku cadang
Portable dry-well calibrator for on-site verification and calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C and accuracy ±0.2°C. Accepts two probes with 3/16 in stem diameter. Suitable for field use in process plants, HVAC, and refrigeration
FLUKE
Portable dry-well calibrator for on-site verification and calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C and accuracy ±0.2°C. Accepts two probes with 3/16 in stem diameter. Suitable for field use in process plants, HVAC, and refrigeration
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with stability ±0.015°C. Accepts probes with stem diameter up to 11.1 mm. Suitable for on-site verification in industrial process control and HVAC applications
FLUKE
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with stability ±0.015°C. Accepts probes with stem diameter up to 11.1 mm. Suitable for on-site verification in industrial process control and HVAC applications
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with accuracy ±0.2°C and stability ±0.015°C. Accepts probes with 6 mm stem diameter. Used for verifying thermocouples, RTDs, and thermistors in industrial and laboratory settings
FLUKE
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with accuracy ±0.2°C and stability ±0.015°C. Accepts probes with 6 mm stem diameter. Used for verifying thermocouples, RTDs, and thermistors in industrial and laboratory settings
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with stability ±0.015°C. Accommodates two 4 mm diameter stems. Suitable for on-site calibration in industrial and laboratory environments
FLUKE
Field metrology well for calibrating temperature sensors and probes. Temperature range -95°C to 140°C with stability ±0.015°C. Accommodates two 4 mm diameter stems. Suitable for on-site calibration in industrial and laboratory environments
Portable drywell for on-site calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C. Accepts two 4 mm diameter probes. Suitable for field verification in industrial temperature measurement applications
FLUKE
Portable drywell for on-site calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C. Accepts two 4 mm diameter probes. Suitable for field verification in industrial temperature measurement applications
Portable drywell for field calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C. Accommodates up to six probes with 1/4 in stem diameter. Suitable for industrial calibration tasks requiring both low and high temperature references
FLUKE
Portable drywell for field calibration of temperature sensors. Temperature range -95°C to 140°C with stability ±0.015°C. Accommodates up to six probes with 1/4 in stem diameter. Suitable for industrial calibration tasks requiring both low and high temperature references