Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR FNDP 25/2 TL SI - Burners & Combustion
FBRBurners & Combustion

FBR FNDP 25/2 TL SI

Pembakar industri FBR FNDP 25/2 TL SI adalah heavy oil burner dua tahap yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan kapasitas alir 12–25 kg/jam dan daya termal 137–285 kW, unit…

SKU 3G-FBR-00270

Merek
FBR
Item
FNDP 25/2 TL SI
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
35 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
350
fan motor w
0.73
power kw max
285
power kw min
137
flow kg h max
25
flow kg h min
12
ip protection
IP 40
noisiness dba
/
pump motor kw
0.55
electrical supply
3
power supply info
3~400V,
current absorption a
4.35
thermal power mcal h
118-245
nominal electric power w
14
max combustion air temp c
60

Konten Lembar Data

HEAVY-OIL BURNERS TWO STAGES SK072005_C_en FNDP 25/2 - FNDP 45/2 - FNDP 70/2 Burners for heavy-oil two stages. Composed by: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of nozzles holder with integrated valves group and additional antigas valve, multistage preheating tank with flanged heating elements, cylindrical metal mesh filter, preheating thermostat, antismoke thermostat, gasket for installation on generator, nozzles, flexible hoses, line filter with heating resistance controlled by thermostat. Fig. FNDP 70/2 FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en TECHNICAL DATA FNDP 25/2 - FNDP 45/2 - FNDP 70/2 MODEL FNDP 25/2 FNDP 45/2 FNDP 70/2 Flow min. - max. * [kg/h] 12-25 20-45 35-70 Thermal power min. - max. * [Mcal/h] 118-245 196-441 343-686 Thermal power min. - max. * [kW] 137-284 227-512 398-796 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Fan motor [kW] 0.73 1.1 1.5 Resistances [kW] 3 4 7.4 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] / / 77-78 Burner weight [kg] 35 36 41 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). OPERATING RANGE DIAGRAM [mbar] 13 11 9 7 5 3 1 -1 0 100 200 300 400 500 600 700 800 900 1000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en DIMENSIONS [MM] I O F H D H G E A B TC-TL C1 - C2 * * Overall dimension with the burner out in position of maintenance. Fig. Dimensions FNDP 25/2 - FNDP 45/2 - FNDP 70/2 MODEL A B C1 C2 * D E F G H I H FNDP 25/2 282 320 640 1150 133 325 155 18 280 / / FNDP 45/2 282 320 640 1150 150 325 155 18 280 / / FNDP 70/2 285 325 655 1165 164 357 170 18 300 10 144 BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N** FNDP 25/2 mm 283 340 M12 145 FNDP 45/2 mm 283 340 M12 160 FNDP 70/2 mm 340 368 M12 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** *** For different flame lengths, please 170 350 contact our Technical-Sales Department. FNDP 25/2 mm FNDP 45/2 mm 170 350 FNDP 70/2 mm 250 350 FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en PRODUCT SPECIFICATION SHORT DESCRIPTION Heavy-oil burners two stages. DETAILED SPECIFICATION Heavy-oil burner two stages composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase with neutral power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter electrically heated and equipped with a thermostat; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FNDP 25/2 - FNDP 45/2 - FNDP 70/2
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

Pembakar industri FBR FNDP 25/2 TL SI adalah heavy oil burner dua tahap yang dirancang untuk aplikasi ketel uap dan peralatan pembakaran industri. Dengan kapasitas alir 12–25 kg/jam dan daya termal 137–285 kW, unit ini dilengkapi motor kipas 0,73 kW, motor pompa 0,55 kW, serta proteksi IP 40. Cocok untuk kebutuhan pembakaran minyak berat di sektor kelapa sawit, semen, dan F&B di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FBR FNDP 25/2 TL SI?

FBR FNDP 25/2 TL SI adalah heavy oil burner dua tahap dengan aliran 12–25 kg/jam, daya termal 137–285 kW, motor kipas 0,73 kW, motor pompa 0,55 kW, suplai listrik 3~400V, proteksi IP 40, dan berat 35 kg.

Untuk apa FBR FNDP 25/2 TL SI digunakan?

Pembakar ini digunakan untuk pembakaran minyak berat (heavy oil) pada ketel uap dan peralatan pembakaran industri. Cocok untuk aplikasi dua tahap di pabrik kelapa sawit, semen, dan industri pengolahan makanan.

Bagaimana cara memilih heavy oil burner yang tepat?

Pilih berdasarkan kapasitas alir (kg/jam) dan daya termal (kW) yang sesuai kebutuhan. FBR FNDP 25/2 TL SI memiliki aliran 12–25 kg/jam dan daya 137–285 kW, cocok untuk beban sedang. Pastikan juga suplai listrik 3~400V dan proteksi IP 40.

Di mana beli FBR FNDP 25/2 TL SI di Indonesia?

Anda dapat membeli FBR FNDP 25/2 TL SI melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Related products

Lainnya dari FBR

Lihat semua FBR suku cadang
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC