Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

<p>Pembakar industri gas dua tahap (2 stages) FBR seri GAS P130/2CE EVO dan GAS P160/2CE dirancang untuk aplikasi ketel uap dan tungku industri dengan efisiensi tinggi. Dilengkapi blower udara bertekanan tinggi dan…

SKU 3G-FBR-00452

Juga terdaftar sebagai: 00252231 · 002522 31 · 002522-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
43 kg
stage
2 stages
fuel type
Gas
nozzle mm
280
fan motor w
2.2
power kw max
1540
power kw min
240
ip protection
IP 40
noisiness dba
82-83
gas consumption
24/71.5-155
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
4.35
thermal power mcal h
206/612-1324
nominal electric power w
2.4
max combustion air temp c
60

Konten Lembar Data

SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE GAS P130/2CE EVO - GAS P160/2CE Gas burners two stages with: die-cast aluminum body, high pressurisation air blower and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; composed by two stages working valve with flow adjustment, safety valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser. Complete of flange and gasket for installation on generator. SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P130/2CE EVO - GAS P160/2CE MODEL GAS P130/2CE EVO GAS P160/2CE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 206/612-1324 258/765-1647 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 240/712-1540 300/890-1915 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 24/71.5-155 30.2/89.5-192 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 9.3/27.6-59.8 11.6/34.5-74.2 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Min. pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 52.4/28.2 64.5/40.4 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360 Nominal electric power [kW] 2.4 4.2 Fan motor [kW] 2.2 4 Nominal motor current absorption [A] 4.35 7.45 Nominal auxiliary absorption [A] 0.7 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 Noisiness *** min. - max [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Control method Class 3 - The tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]). GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE 18 GAS P130/2CE EVO 16 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] GAS P130/2CE EVO The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. 16 GAS P160/2CE 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] GAS P160/2CE The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE DIMENSIONS [MM] 320 40 183 211 320 O 209 320 284 20 510 320 TC-TL 148 240 343 545 380 803 - 1388 ** 555 Fig. Dimensions GAS P130/2CE EVO 320 40 183 211 320 O 209 320 284 20 510 320 TC-TL 148 240 402 545 380 803 - 1388 ** 555 Fig. Dimensions GAS P160/2CE ** Overall dimension with the burner out in position of maintenance. TC - TL: See "FLAME TUBE LENGTH" GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE BOILER PLATE The dimensions of the burner fixing flange (holes threaded or studded) must be as per the drawing. *** Recommended hole diameter on the generator. MODEL L min L*** L max M N min N max GAS P130/2CE EVO mm 220 220 250 M14 340 368 GAS P160/2CE mm 220 220 250 M14 340 368 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 280 TL mm 400 **** **** For different flame lengths, please contact our Technical-Sales Department. GAS P130/2CE EVO - GAS P160/2CE SK071098_A_en GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO GAS P160/2CE BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 V V 1 ' Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

<p>Pembakar industri gas dua tahap (2 stages) FBR seri GAS P130/2CE EVO dan GAS P160/2CE dirancang untuk aplikasi ketel uap dan tungku industri dengan efisiensi tinggi. Dilengkapi blower udara bertekanan tinggi dan kepala pembakaran yang dapat disetel, produk ini menghasilkan nyala api yang stabil dengan daya termal maksimum hingga 1540 kW (GAS P130/2CE EVO) dan 1915 kW (GAS P160/2CE). Rangkaian gas terintegrasi mencakup katup kerja dua tahap, katup pengaman, sakelar tekanan gas minimum, sistem pengujian katup, filter gas, dan stabilisator tekanan gas. Tersedia dalam versi gas alam (metana) atau LPG, dengan perlindungan IP 40 dan suplai listrik 3~400V, 1/N~230V-50Hz.</p>

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi teknis pembakar gas FBR GAS P130/2CE EVO?

Pembakar gas FBR GAS P130/2CE EVO memiliki daya termal 240/712-1540 kW, konsumsi gas G20 24/71.5-155 Nm³/h, motor kipas 2.2 kW, arus nominal 4.35 A, dan perlindungan IP 40. Suplai listrik 3~400V, 1/N~230V-50Hz. Berat 43 kg dengan diameter nosel 280 mm.

Untuk apa pembakar gas FBR GAS P160/2CE digunakan?

Pembakar gas FBR GAS P160/2CE digunakan pada ketel uap industri, tungku, dan sistem pembakaran lainnya yang memerlukan nyala api stabil dua tahap. Daya termal maksimum mencapai 1915 kW dengan konsumsi gas G20 hingga 192 Nm³/h. Cocok untuk gas alam (metana) atau LPG.

Apa perbedaan antara FBR GAS P130/2CE EVO dan GAS P160/2CE?

Perbedaan utama terletak pada kapasitas daya: GAS P130/2CE EVO memiliki daya termal maksimum 1540 kW, sedangkan GAS P160/2CE mencapai 1915 kW. Motor kipas GAS P160/2CE 4 kW (vs 2.2 kW) dengan arus nominal 7.45 A (vs 4.35 A). Keduanya dua tahap dengan perlindungan IP 40.

Di mana beli pembakar gas FBR di Indonesia?

Anda dapat membeli pembakar gas FBR seri GAS P130/2CE EVO dan GAS P160/2CE melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi proyek Anda.

Bagaimana cara memilih antara FBR GAS P130/2CE EVO dan GAS P160/2CE?

Pilih GAS P130/2CE EVO jika kebutuhan daya termal Anda maksimal 1540 kW dengan konsumsi gas G20 hingga 155 Nm³/h. Pilih GAS P160/2CE jika memerlukan daya hingga 1915 kW dan konsumsi gas hingga 192 Nm³/h. Keduanya memerlukan tekanan gas minimum 52.4 mbar (G20) dan suplai listrik 3~400V.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 130/2 CE EVO TC | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TC | Variant: variant_1 | Subgroup: Burner
GAS P 130/M CE EVO TC | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TC | Variant: variant_2 | Subgroup: Burner
GAS P 130/M CE EVO TC | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TC | Variant: variant_1 | Subgroup: Burner
GAS P 130/2 CE EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TL | Variant: variant_2 | Subgroup: Burner
GAS P 130/2 CE EVO TL | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 130/2 CE EVO TL | Variant: variant_1 | Subgroup: Burner
GAS P 130/M CE EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE EVO TL | Variant: variant_2 | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL