Konten Lembar Data
GAS BURNER LOW NOX (CLASS 4) TWO STAGES 071100_A_en
mod: GAS P130/2CE LX4 EVO
GASBURNERSLOWNOX(CLASS4)TWO
STAGES
GAS P130/2CE LX4 EVO
Gas burner two stages with: die-cast aluminum body, high pressurisation air blower with reverse blades and
combustion head at high efficiency and high flame stability.
Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy
setting and maintenance.
Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order).
Gas train completely assembled and tested; composed by two stages working valve with flow adjustment,
safety valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser.
Complete of flange and gasket for installation on generator.
Fig. GAS P130/2CE LX4 EVO
GAS P130/2CE LX4 EVO
GAS BURNER LOW NOX (CLASS 4) TWO STAGES 071100_A_en
mod: GAS P130/2CE LX4 EVO
TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P130/2CE LX4 EVO
MODEL GAS P130/2CE LX4 EVO
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 258/612-1247
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 300/712-1450
Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 30.2/71.5-146
Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.6/27.6-56.2
Fuel: NATURAL GAS (second family) - L.P.G. (third family)
Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R
Intermitted working operation (min. 1 stop every 24 hours) two stages
Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80%
Max. temperature combustion air [°C] 60
Minimum pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 52.8/28
Maximum pressure at the entry of valves (Pe. max) [mbar] 360
Nominal electric power [kW] 2.4
Fan motor [kW] 2.2
Nominal motor current absorption [A] 4.35
Nominal auxiliary absorption [A] 0.7
Power supply: 3~400V, 1/N~230V-50Hz
Electric protection degree: IP 40
NOx Class, NATURAL GAS (second family) 4
NOx Class, L.P.G. (third family) 4
Noisiness *** min. - max. [dB(A)] 82-83
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level).
** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of
value 0 (zero).
*** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law -
Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]).
GAS P130/2CE LX4 EVO
071100_A_en
GAS BURNER LOW NOX (CLASS 4) TWO STAGES
mod: GAS P130/2CE LX4 EVO
18
GAS P130/2CE‐LX4 EVO
16
14
12
10
8
6
4
2
0
0 200 400 600 800 1000 1200 1400 1600 1800
Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar]
The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the
boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-
compliance, contact the manufacturer.
GAS P130/2CE LX4 EVO
071100_A_en
GAS BURNER LOW NOX (CLASS 4) TWO STAGES
mod: GAS P130/2CE LX4 EVO
DIMENSIONS [MM]
40 183
320
320
320 211
320
O 209
284 284
20
510
TC-TL
240 343
148 B
380 803 - 1388**
A
Fig. Dimensions GAS P130/2 CE LX4 EVO
GAS TRAIN A B
** Overall dimension with the burner out in position of maintenance.
D2"-S 555 396
TC - TL: see "flame tube length"
GAS P130/2CE LX4 EVO
071100_A_en
GAS BURNER LOW NOX (CLASS 4) TWO STAGES
mod: GAS P130/2CE LX4 EVO
BOILER PLATE
The dimensions of the boiler plate must be as indicated in
the drawing.
*** Suggested dimension of connection between
burner and generator.
MODEL L min L*** L max M N min N
max
GAS P130/2CE LX4 EVO mm 220 220 250 M14 340 368
FLAME TUBE LENGTH
Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it
must be greater than the thickness of the boiler door included its insulation.
In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between
the flame tube and front door with refractory material. This protection material must not impede flame tube extraction.
FLAME TUBE LENGTH
TC mm 280
TL mm 400 ****
**** For different flame lengths, please contact our Technical-Sales Department.
GAS P130/2CE LX4 EVO
071100_A_en
GAS BURNER LOW NOX (CLASS 4) TWO STAGES
mod: GAS P130/2CE LX4 EVO
BURNER SIGNAL DESCRIPTION
In the picture below there are indicated all the signalation present on the burner:
2
V
V
1
Fig. Burner signal description
LEGEND
1) ON/OFF button
2) Reset from lockout button + status lamp
The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics
and interface diagnostics.
In normal operation, the different operating states are indicated in the form of color codes; please refer to
electrical device handbook supplied with the present instructions.
After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up.
By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault
can be activated; please refer to electrical device handbook supplied with the present instructions.
For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control.
Press the lockout reset button (pos.2) for about 1 second (<3 seconds).
After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up.
For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds).
GAS P130/2CE LX4 EVO
071100_A_en
GAS BURNER LOW NOX (CLASS 4) TWO STAGES
mod: GAS P130/2CE LX4 EVO
PRODUCT SPECIFICATION
SHORT DESCRIPTION
Gas burner two stages low emissions class 4 (NOx < 60 mg/kWh).
DETAILED SPECIFICATION
Gas burner two stages low emissions class 4 (NOx < 60 mg/kWh). composed by:
• Die-cast aluminum body;
• High pressurisation air blower with reverse blades;
• Combustion head at high performance and elevated flame stability equipped with inox steel blast tube and inox steel flame disc;
• Flange and…