Kami mengirim ke Indonesia — pintu ke pintu, bea cukai dan logistik ditangani oleh 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS P130/MCE LX4 EL EVO dan GAS P160/MCE LX4 EL adalah pembakar gas low NOx dua tahap progresif atau modulating (PID fully modulating) dengan daya termal 280–1450 kW, konsumsi gas 20,1/58,3–116,7, dan nozzle 280…

SKU 3G-FBR-00443

Juga terdaftar sebagai: 00246831 · 002468 31 · 002468-31

Merek
FBR
Item
variant_2
Kategori
Burners & Combustion
UNSPSC
40101834 — Burners
Tersedia untuk Dipesan
Stok tersedia & bea cukai ditangani
  • 6–10 business days door-to-door; Bea Cukai clearance typically 3–5 business days.
  • Invoicing in IDR or USD. Bank transfer and corporate PO accepted.
  • Dikirim ke: Jakarta, Surabaya, Bandung, Medan, Batam
Harga dagang sesuai penawaran — balasan dalam 24 jam
Jumlah
WhatsApp seorang insinyurMessage via Telegram
Tidak perlu akun — permintaan penawaran Anda langsung masuk ke tim insinyur kami. Akun gratis memungkinkan Anda melacak penawaran dan memesan ulang lebih cepat.
Distributor Resmi
Langsung dari OEM
Pengiriman ke Seluruh Dunia
Pengiriman udara & laut
Lembar Data Atas Permintaan
Spesifikasi teknis
Penawaran 1 Hari
Balasan dalam 24 jam

Local availability & support — Indonesia

Phone
+65 8878 8355

Spesifikasi Teknis

FBR
Weight
52 kg
stage
2 stages sliding or modulating
fuel type
Gas low nox
nozzle mm
280
fan motor w
1.5
power kw max
1450
power kw min
280
ip protection
IP 54
noisiness dba
81-82
gas consumption
20.1/58.3-116.7
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.6
thermal power mcal h
172/500-1000
nominal electric power w
1.7
max combustion air temp c
60

Konten Lembar Data

GAS BURNERS LOW NOX (CLASS 4) TWO STAGES PROGRESSIVE SK073074_A_en OR MODULATING WITH ELECTRONIC CONTROL BOX mod: GAS P130/MCE LX4 EL EVO GAS P160/MCE LX4 EL GAS P130/MCE LX4 EL EVO - GAS P160/MCE LX4 EL Gas burners with electronic control box. Two stages progressive or modulating operation (if equipped with addition of optional modulation kit PID and probe; to guarantee an ideal proportionality of the power supplied to the thermal load). Composed by: die-cast aluminum body ,high pressurisation air blower and combustion head at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order). Gas train completely assembled and tested; composed by working valve with flow adjustment, safety valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser. Complete of flange and gasket for installation on generator. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator and one servomotor for the air shutter. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / gas ratio) With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet). Fig. GAS P130/MCE LX4 EL EVO GAS P130/MCE LX4 EL EVO - GAS P160/MCE LX4 EL GAS BURNERS LOW NOX (CLASS 4) TWO STAGES PROGRESSIVE SK073074_A_en OR MODULATING WITH ELECTRONIC CONTROL BOX mod: GAS P130/MCE LX4 EL EVO GAS P160/MCE LX4 EL CONTROL BOX LAMTEC BT3 Fig. Control box Lamtec BT3 GAS P130/MCE LX4 EL EVO - GAS P160/MCE LX4 EL GAS BURNERS LOW NOX (CLASS 4) TWO STAGES PROGRESSIVE SK073074_A_en OR MODULATING WITH ELECTRONIC CONTROL BOX mod: GAS P130/MCE LX4 EL EVO GAS P160/MCE LX4 EL TECHNICAL DATA GAS P130/MCE LX4 EL EVO - NATURAL GAS - MODEL GAS P130/MCE LX4 EL EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 241/612-1247 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 280/712-1450 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 28.2/71.5-146 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) Intermitted working operation (min. 1 stop every 24 hours) modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D2"-S NATURAL GAS ** [mbar] 52.8 Min. pressure gas train D2"-S MBE NATURAL GAS ** [mbar] -- Min. pressure gas train DN65-FS65 NATURAL GAS ** [mbar] 35.5 Min. pressure gas train DN80-FS80 NATURAL GAS ** [mbar] 29.8 Maximum pressure at the entry of valves (D2") [mbar] 360 Maximum pressure at the entry of valves (D2" MBE - DN65 - DN80) [mbar] 500 Nominal electric power [kW] 2.4 Fan motor [kW] 2.2 Nominal motor current absorption [A] 4.35 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 54 NOx Class, NATURAL GAS (second family) 4 Noisiness *** min. - max. [dB(A)] 81-82 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). GAS P130/MCE LX4 EL EVO - GAS P160/MCE LX4 EL GAS BURNERS LOW NOX (CLASS 4) TWO STAGES PROGRESSIVE SK073074_A_en OR MODULATING WITH ELECTRONIC CONTROL BOX mod: GAS P130/MCE LX4 EL EVO GAS P160/MCE LX4 EL TECHNICAL DATA GAS P130/MCE LX4 EL EVO - L.P.G. - MODEL GAS P130/MCE LX4 EL EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 258/612-1247 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 300/712-1450 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.6/27.6-56.2 Fuel: L.P.G. (third family) Fuel category: I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D2"-S L.P.G. ** [mbar] 38.9 Min. pressure gas train D2"-S MBE L.P.G. ** [mbar] -- Min. pressure gas train DN65-FS65 L.P.G. ** [mbar] 33 Min. pressure gas train DN80-FS80 L.P.G. ** [mbar] 30.2 Maximum pressure at the entry of valves (D2") [mbar] 360 Maximum pressure at the entry of valves (D2" MBE - DN65 - DN80) [mbar] 500 Nominal electric power [kW] 2.4 Fan motor [kW] 2.2 Nominal motor current absorption [A] 4.35 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 54 NOx Class, L.P.G. (third family) 4 Noisiness *** min. - max. [dB(A)] 81-82 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). GAS P130/MCE LX4 EL EVO - GAS P160/MCE LX4 EL GAS BURNERS LOW NOX (CLASS 4) TWO STAGES PROGRESSIVE SK073074_A_en OR MODULATING WITH ELECTRONIC CONTROL BOX mod: GAS P130/MCE LX4 EL EVO GAS P160/MCE LX4 EL TECHNICAL DATA GAS P160/MCE LX4 EL - NATURAL GAS - MODEL GAS P160/MCE LX4 EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 206/765-1647 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 240/890-1915 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 24/89.5-192 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) Intermitted working operation (min. 1 stop every 24 hours) modulating Environmental conditions operation / storage: -15...+40°C /…

Dokumen Teknis

Tidak ada dokumen teknis yang tersedia untuk produk ini.
Minta dokumentasi
Tidak yakin ini adalah suku cadang yang tepat? Minta rekomendasi.

Butuh bantuan pemasangan atau rekayasa?

Instalasi, komisioning, rencana pemeliharaan, desain sistem, dan penawaran produk + layanan bundel — satu tim menangani cakupan penuh.
Bicaralah dengan seorang insinyur

Ajukan pertanyaan

FBR Produk
3G Electric (S) Pte. Ltd. — Singapore

Deskripsi Produk

FBR GAS P130/MCE LX4 EL EVO dan GAS P160/MCE LX4 EL adalah pembakar gas low NOx dua tahap progresif atau modulating (PID fully modulating) dengan daya termal 280–1450 kW, konsumsi gas 20,1/58,3–116,7, dan nozzle 280 mm. Dilengkapi motor kipas 1,5 kW, proteksi IP 54, serta bodi aluminium die-cast untuk ketahanan di lingkungan industri. Cocok untuk aplikasi ketel uap dan peralatan pembakaran di Indonesia.

Supplied to Indonesia — compatible with 50 Hz installations. DHL Express delivery to Jakarta, Surabaya, Bandung, customs and duties handled door-to-door.

Pertanyaan yang Sering Diajukan

Apa spesifikasi FBR GAS P130/MCE LX4 EL EVO?

FBR GAS P130/MCE LX4 EL EVO adalah pembakar gas low NOx dua tahap progresif atau modulating dengan daya termal 280–1450 kW, konsumsi gas 20,1/58,3–116,7, nozzle 280 mm, motor kipas 1,5 kW, proteksi IP 54, dan suplai listrik 3~400V/1~230V-50Hz.

Untuk apa FBR GAS P160/MCE LX4 EL digunakan?

FBR GAS P160/MCE LX4 EL digunakan sebagai pembakar gas low NOx untuk ketel uap dan peralatan pembakaran industri. Dengan dua tahap progresif atau modulating (PID), burner ini memastikan rasio udara/gas optimal dan emisi rendah (NOx < 60 mg/kWh, kelas 4).

Bagaimana cara memilih FBR gas burner yang tepat?

Pilih FBR gas burner berdasarkan daya termal yang dibutuhkan (280–1450 kW), jenis gas (metana atau LPG), dan kebutuhan kontrol (progresif atau modulating). Pastikan suplai listrik sesuai (3~400V/1~230V-50Hz) dan nozzle 280 mm cocok dengan dimensi ketel uap Anda.

Di mana beli FBR gas burner di Indonesia?

Anda dapat membeli FBR GAS P130/MCE LX4 EL EVO dan GAS P160/MCE LX4 EL melalui 3G Electric, distributor resmi yang memasok dan mengirimkan peralatan industri ke seluruh Indonesia. Kami menangani logistik dan bea cukai untuk memastikan produk sampai ke lokasi Anda.

Apa keunggulan FBR gas burner low NOx?

Keunggulan FBR gas burner low NOx meliputi emisi rendah (NOx < 60 mg/kWh, kelas 4), kontrol dua tahap progresif atau modulating, bodi aluminium die-cast, servomotor independen untuk gas dan udara, serta display untuk penyesuaian parameter operasi dan kurva udara/gas.

Digunakan dalam

Aplikasi umum untuk FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Produk

3G Electric memasok FBR burners & combustion. Kami menyediakan produk asli dengan ketersediaan tersedia di gudang untuk SKU umum, dokumentasi teknis, dukungan commissioning, dan layanan garansi — di seluruh dunia.

Anda mungkin juga membutuhkan

Rangkaian Gas & Katup Gas Transformator Pengapian Kontrol Pembakar Suku Cadang Semua Produk

Compatible alternatives & equivalents

Cross-referenced by specification & description
FBR
FBR
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: metano | Subgroup: Burner

Lainnya dari FBR

Lihat semua FBR suku cadang
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL